{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T14:02:50Z","timestamp":1788876170899,"version":"build-2803163510"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2024,5,3]],"date-time":"2024-05-03T00:00:00Z","timestamp":1714694400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100004731","name":"Natural Science Foundation of Zhejiang Province","doi-asserted-by":"publisher","award":["LQ23H120003"],"award-info":[{"award-number":["LQ23H120003"]}],"id":[{"id":"10.13039\/501100004731","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[2024,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Spectacle lenses with peripheral lenslets have shown promise for myopia control by providing peripheral myopic defocus signals. Here, we aimed to investigate the impact of prolonged exposure (&gt;6 months) to peripheral myopic defocus on visual information processing in myopic children.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      The study included 30 myopic children who habitually wore spectacle lenses with highly aspherical lenslets (HAL group) and 34 children who habitually wore single\u2010vision (SV group) spectacles. The quick contrast sensitivity function (qCSF) was used to measure contrast sensitivity (CS) under conditions of no or high noise. Both groups were tested with HAL and SV lenses. The perceptual template model was utilised to fit the contrast sensitivity function (CSF) and determine differences in information processing efficiency through internal additive noise () and perceptual template gain (\n                      <jats:italic>\u03b2<\/jats:italic>\n                      ).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The areas under the log CSF in the SV group were significantly higher than for the HAL group in both zero\u2010noise conditions with the SV test lens (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.03) and high\u2010noise conditions with the HAL test lens (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.02). For 2 cycle per degree (cpd) stimuli,\n                      <jats:italic>\u03b2<\/jats:italic>\n                      was significantly higher in the SV group with the HAL test lens than in the HAL group (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.02), while there was a trend towards a significant difference in\n                      <jats:italic>\u03b2<\/jats:italic>\n                      for 6 cpd stimuli (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.07). However, there were no significant differences in  between the two groups, with or without noise interference.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>\n                      The reduced CS observed in myopic children wearing HAL lenses for 6\u2009months or more may be due to decreased\n                      <jats:italic>\u03b2<\/jats:italic>\n                      . This suggests that prolonged use of spectacle lenses with peripheral myopic defocus signals may compromise the central visual system's ability to process additional external noise, resulting in decreased efficiency in visual information processing.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/opo.13325","type":"journal-article","created":{"date-parts":[[2024,5,3]],"date-time":"2024-05-03T04:59:14Z","timestamp":1714712354000},"page":"1010-1016","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Peripheral myopic defocus signal affects the efficiency of visual information processing in myopic children"],"prefix":"10.1007","volume":"44","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1119-3058","authenticated-orcid":false,"given":"Chenglu","family":"Ding","sequence":"first","affiliation":[{"name":"National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital Wenzhou Medical University  Wenzhou China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-2097-9048","authenticated-orcid":false,"given":"Danyi","family":"Mao","sequence":"additional","affiliation":[{"name":"National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital Wenzhou Medical University  Wenzhou China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xue","family":"Li","sequence":"additional","affiliation":[{"name":"National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital Wenzhou Medical University  Wenzhou China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7694-513X","authenticated-orcid":false,"given":"Yingying","family":"Huang","sequence":"additional","affiliation":[{"name":"National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital Wenzhou Medical University  Wenzhou China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fang","family":"Hou","sequence":"additional","affiliation":[{"name":"National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital Wenzhou Medical University  Wenzhou China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hao","family":"Chen","sequence":"additional","affiliation":[{"name":"National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital Wenzhou Medical University  Wenzhou China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2103-8345","authenticated-orcid":false,"given":"Jinhua","family":"Bao","sequence":"additional","affiliation":[{"name":"National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital Wenzhou Medical University  Wenzhou China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,5,3]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(94)00233-C"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.3389\/fnhum.2021.711713"},{"key":"e_1_2_9_4_1","first-page":"1171","article-title":"One\u2010year myopia control efficacy of spectacle lenses with aspherical lenslets","volume":"106","author":"Bao J","year":"2021","journal-title":"Br J Ophthalmol"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1001\/jamaophthalmol.2022.0401"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2018-313739"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.3389\/fnins.2021.667329"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2019.12.002"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2009.06.005"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(97)00273-3"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2006.06.013"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.3389\/fpsyg.2021.740759"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2023.03.030"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.13098"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.486555"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.7.6.9"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1163\/156856897X00366"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0090579"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.9.9.11"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.3389\/fnins.2022.996908"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1155\/2022\/9306848"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40662\u2010022\u201000304\u20103"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(99)00059-0"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1523\/JNEUROSCI.23-07-02522.2003"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(94)90073-6"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12878"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12031"}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/opo.13325","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:23:53Z","timestamp":1767785033000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/opo.13325"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,3]]},"references-count":26,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2024,7]]}},"alternative-id":["10.1111\/opo.13325"],"URL":"https:\/\/doi.org\/10.1111\/opo.13325","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,3]]},"assertion":[{"value":"2023-10-07","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-04-20","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-05-03","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}