{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T16:43:43Z","timestamp":1793724223971,"version":"4.6.1"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2025,5,6]],"date-time":"2025-05-06T00:00:00Z","timestamp":1746489600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100020485","name":"CooperVision","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100020485","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>This investigation examined the image and vision quality of two commercially available daily disposable myopia control soft contact lenses.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Wavefront errors were measured with an SHS Ophthalmic aberrometer for two myopia control soft contact lenses: a coaxially designed dual\u2010focus lens (omafilcon A, CooperVision MiSight\u00ae 1\u2009day, MS1d) and a design employing multiple add powers that included non\u2010coaxial optics in annular add zones (senofilcon A, Johnson &amp; Johnson Vision ACUVUE\u00ae Abiliti\u2122 1\u2010Day, AB). Geometric optics ray tracing generated point\u2010spread functions and wave optics were used to compare modulation transfer functions (MTFs) and simulated letter images. Twenty\u2010six myopic children completed a randomised, non\u2010dispensing, contralateral double\u2010masked clinical trial. After 1\u2009h of wear, right and left eye visual acuity (VA), subjective vision quality and lens preference (Likert) were assessed while viewing monocularly.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The lens containing non\u2010coaxial optics employed a small central zone with approximately +10.00 D of added power and two annular rings with a power gradient typical of non\u2010coaxial optics. The coaxial design contained a centre zone with a distance correction and two annular zones with a fixed add power of approximately +2.00 D. MTFs and simulated images were better with small pupils, which was most noticeable with the coaxial design. Distance VA was \u20100.02 \u00b1 0.04 with MS1d and 0.09 \u00b1 0.08 with\u00a0AB,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.01. The majority of participants (77%) reported a preference for one lens; 54% preferred the MS1d and 23% preferred the AB lens.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Myopia control contact lenses employing coaxial or a mixture of coaxial and non\u2010coaxial optics both reduced retinal image contrast but successfully imaged high spatial frequencies and provided high quality of vision. Image and vision quality were slightly superior in the lens employing coaxial optics alone.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/opo.13521","type":"journal-article","created":{"date-parts":[[2025,5,6]],"date-time":"2025-05-06T08:15:44Z","timestamp":1746519344000},"page":"1142-1150","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Optical characterisation and vision quality assessment of two myopia control contact lenses"],"prefix":"10.1007","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-1910-5578","authenticated-orcid":false,"given":"Josh","family":"Richards","sequence":"first","affiliation":[{"name":"Indiana University School of Optometry  Bloomington Indiana USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5824-7135","authenticated-orcid":false,"given":"Matt","family":"Jaskulski","sequence":"additional","affiliation":[{"name":"Indiana University School of Optometry  Bloomington Indiana USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5031-791X","authenticated-orcid":false,"given":"Jill","family":"Woods","sequence":"additional","affiliation":[{"name":"University of Waterloo School of Optometry and Vision Science  Waterloo Ontario Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarah","family":"Guthrie","sequence":"additional","affiliation":[{"name":"University of Waterloo School of Optometry and Vision Science  Waterloo Ontario Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9568-2064","authenticated-orcid":false,"given":"Pete","family":"Kollbaum","sequence":"additional","affiliation":[{"name":"Indiana University School of Optometry  Bloomington Indiana USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,6]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2017-311266"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.53.5.300"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.14-14250"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12110"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000001410"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12725"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.13098"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1001\/jamaophthalmol.2022.0401"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598\u2010023\u201032700\u20107"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.xops.2022.100232"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmjophth\u20102024\u2010001790"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2020.10834"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2023.03.030"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.13240"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3182812205"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12959"},{"key":"e_1_2_10_18_1","unstructured":"BrennanNA ChengX HernandezJV CollinsMJ DavisBA YiF et\u00a0al.Ophthalmic lens with an optically non\u2010coaxial zone for myopia control. EP3667402A1 2020[cited 2024 Feb 14]. Available from:https:\/\/patents.google.com\/patent\/EP3667402A1\/en?q=(non\u2010coaxial)&q=(contact+lens)&assignee=Johnson+%26+Johnson+Vision+Care"},{"key":"e_1_2_10_19_1","first-page":"5437","article-title":"Assessment of off\u2010eye power profile for a non\u2010coaxial multi\u2010zone soft contact lens via deflectometry and ray tracing methods","volume":"65","author":"Nti AN","year":"2024","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.13182"},{"key":"e_1_2_10_21_1","article-title":"Design concepts for a myopia control soft contact lens","volume":"63","author":"Brennan NA","year":"2022","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e318185280e"},{"key":"e_1_2_10_23_1","article-title":"Metrics of optical quality of the eye","volume":"4","author":"Thibos L","year":"2003","journal-title":"J Vis"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12619"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000144752.18836.1b"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.13278"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.1989.tb00941.x"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.15.002536"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1167\/10.14.18"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.12-11219"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199512000-00004"},{"key":"e_1_2_10_32_1","unstructured":"ChengX JieX NixonA.Visual performance of a soft contact lens with novel myopia control optics. Optom Vis Sci 2024;101:E\u2010abstract 230033."},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000000762"}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/opo.13521","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:24:28Z","timestamp":1767785068000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/opo.13521"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,6]]},"references-count":32,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025,7]]}},"alternative-id":["10.1111\/opo.13521"],"URL":"https:\/\/doi.org\/10.1111\/opo.13521","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,6]]},"assertion":[{"value":"2025-02-03","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-04-18","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-06","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}