{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T14:21:41Z","timestamp":1767795701623,"version":"3.49.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2025,7,18]],"date-time":"2025-07-18T00:00:00Z","timestamp":1752796800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To explore the agreement between computationally modelled point\u2010spread functions (PSFs) and multifocal soft contact lens wearers' descriptions of image quality.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      In Phase 1, participants were fitted with a single vision soft contact lens (SCL) in the left eye, and four different multifocal (MF) SCLs in the right eye in randomised order. Aberrometry measures of the MFSCL\u2010wearing right eye were collected while participants viewed a point source monocularly using their left eye and drew their perception of the source. The predicted right eyes' PSFs were computed from the aberrometry data using a geometrical optics PSF calculation. In Phase 2, participants completed a Likert item questionnaire designed to identify salient features in the PSFs. Consensus among the participants about these features was assessed quantitatively using Yule's\n                      <jats:italic>Q<\/jats:italic>\n                      . Participants also rated the similarity between pairs of PSFs. Non\u2010metric multidimensional scaling (MDS) and Procrustes transformation analyses were used to derive and compare image similarity spaces for the drawn and computed PSFs, respectively. Lastly, two observers completed an image matching task, in which they selected the best\u2010matching drawn PSF for each computed PSF.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Significant similarities between computed and hand\u2010drawn PSFs were demonstrated both qualitatively and quantitatively. Inter\u2010rater agreement for image features was statistically significant (Yule's\n                      <jats:italic>Q<\/jats:italic>\n                      \u2009=\u20090.63;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05). Stress values for three\u2010dimensional MDS configurations were &lt;0.1, indicating excellent correspondence between MDS configurations and observed similarity ratings. Procrustes analysis confirmed strong concordance between hand\u2010drawn and computed 3D configurations (congruence coefficient\u2009=\u20090.90). Image matches were inconsistent with random guessing (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Results indicate good agreement between the PSF image quality drawn by participants and that predicted from aberrometry measures. This study has demonstrated potential for leveraging the correspondence between subjectively perceived and computationally derived representations of image quality in both clinical and contact lens research and development processes.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/opo.13556","type":"journal-article","created":{"date-parts":[[2025,7,18]],"date-time":"2025-07-18T13:07:24Z","timestamp":1752844044000},"page":"2009-2024","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Predicting patient\u2010reported quality of vision through multifocal optics"],"prefix":"10.1007","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9568-2064","authenticated-orcid":false,"given":"Pete","family":"Kollbaum","sequence":"first","affiliation":[{"name":"School of Optometry Indiana University  Bloomington Indiana USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5157-2557","authenticated-orcid":false,"given":"Dawn","family":"Meyer","sequence":"additional","affiliation":[{"name":"School of Optometry Indiana University  Bloomington Indiana USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-0514-2132","authenticated-orcid":false,"given":"Nitya","family":"Murthy","sequence":"additional","affiliation":[{"name":"School of Optometry Indiana University  Bloomington Indiana USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4080-1326","authenticated-orcid":false,"given":"Javier","family":"Gantes\u2010Nunez","sequence":"additional","affiliation":[{"name":"School of Optometry Indiana University  Bloomington Indiana USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5824-7135","authenticated-orcid":false,"given":"Matt","family":"Jaskulski","sequence":"additional","affiliation":[{"name":"School of Optometry Indiana University  Bloomington Indiana USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7010-7300","authenticated-orcid":false,"given":"Martin","family":"Rickert","sequence":"additional","affiliation":[{"name":"School of Optometry Indiana University  Bloomington Indiana USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,7,18]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000000031"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2022.101599"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2016.01.006"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3182812205"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-197611000-00006"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2013.04.015"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199306000-00005"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2010.04.001"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1167\/4.4.7"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.36.000B97"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSA.67.001508"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12420"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000232842.60932.af"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1167\/4.4.8"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000000275"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2021.02.005"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000216098.62165.34"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0000000000001435"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.2009.00358.x"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/opo.12619"},{"key":"e_1_2_10_22_1","unstructured":"JaskulskiM GantesJ KollbaumP.Improved methods for quantifying ex\u2010vivo and on\u2010eye power distributions with zonal multifocal contact lenses. Optom Vis Sci2021."},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.11.001993"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02288916"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02289630"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1126\/science.210.4468.390"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1745-3984.2003.tb01108.x"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.18637\/jss.v031.i03"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.18637\/jss.v102.i10"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.17713\/ajs.v51i4.1423"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.4135\/9781412985130"},{"key":"e_1_2_10_32_1","first-page":"772","article-title":"Goodness\u2010of\u2010fit assessment in multidimensional scaling and unfolding","volume":"51","author":"Mair P","year":"2016","journal-title":"Multivar Behav Res"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02289621"},{"key":"e_1_2_10_34_1","first-page":"57","article-title":"Tucker's congruence coefficient as a meaningful index of factor similarity","volume":"2","author":"Lorenzo\u2010Seva U","year":"2006","journal-title":"Methodol Eur J Res Methods Behav Soc Sci"},{"key":"e_1_2_10_35_1","first-page":"155","volume-title":"Psychological scaling: theory and applications","author":"Tucker LR","year":"1960"},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.14.000353"}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/opo.13556","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:24:45Z","timestamp":1767785085000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/opo.13556"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,18]]},"references-count":35,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2025,11]]}},"alternative-id":["10.1111\/opo.13556"],"URL":"https:\/\/doi.org\/10.1111\/opo.13556","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,18]]},"assertion":[{"value":"2025-03-07","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-07-06","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-07-18","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}