{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T18:47:26Z","timestamp":1778784446473,"version":"3.51.4"},"reference-count":14,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2014,5,29]],"date-time":"2014-05-29T00:00:00Z","timestamp":1401321600000},"content-version":"vor","delay-in-days":28,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopaedic Surgery"],"published-print":{"date-parts":[[2014,5]]},"abstract":"<jats:sec><jats:title>Objective<\/jats:title><jats:p>To share our preliminary clinical success and failure with using an external locking compression plate (<jats:styled-content style=\"fixed-case\">LCP<\/jats:styled-content>) for proximal tibial fractures, further refine the indications for this procedure and review relevant published reports.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The current study reports two cases of proximal tibial fracture treated with external <jats:styled-content style=\"fixed-case\">LCP<\/jats:styled-content> as the second stage of a two\u2010stage treatment. One patient was a 59\u2010year\u2010old man with a closed proximal tibial\/fibular fracture caused by falling on ice while getting out of his car, and another patient was a 42\u2010year\u2010old male smoker with right comminuted proximal tibia, tibial plateau and proximal fibular fractures. The outcomes were evaluated by radiographs and weight bearing status.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>In the first case, the fracture healed uneventfully whereas the second case required further open\u2010reduction with internal fixation because correct alignment could not be achieved with an external <jats:styled-content style=\"fixed-case\">LCP<\/jats:styled-content>.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Correct alignment of proximal tibial fractures followed by use of an external <jats:styled-content style=\"fixed-case\">LCP<\/jats:styled-content> can achieve favorable outcomes.<\/jats:p><\/jats:sec>","DOI":"10.1111\/os.12101","type":"journal-article","created":{"date-parts":[[2014,5,30]],"date-time":"2014-05-30T02:31:50Z","timestamp":1401417110000},"page":"154-157","source":"Crossref","is-referenced-by-count":15,"title":["Staged Treatment of Proximal Tibial Fracture Using External Locking Compression Plate"],"prefix":"10.1111","volume":"6","author":[{"given":"Nabil A.","family":"Ebraheim","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery University of Toledo Medical Center  Toledo Ohio USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Trevor","family":"Carroll","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Toledo Medical Center  Toledo Ohio USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maged","family":"Hanna","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Toledo Medical Center  Toledo Ohio USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jingwei","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Toledo Medical Center  Toledo Ohio USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiayong","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Toledo Medical Center  Toledo Ohio USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2014,5,29]]},"reference":[{"key":"e_1_2_4_2_1","first-page":"62","article-title":"Staged management of high\u2010energy proximal tibia fractures","volume":"62","author":"Tejwani NC","year":"2004","journal-title":"Bull Hosp Jt Dis"},{"key":"e_1_2_4_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0030-5898(03)00079-8"},{"key":"e_1_2_4_4_1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-198466080-00011"},{"key":"e_1_2_4_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-200210000-00003"},{"key":"e_1_2_4_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005373-200004000-00006"},{"key":"e_1_2_4_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-009-1148-4"},{"key":"e_1_2_4_8_1","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e31818f8de4"},{"key":"e_1_2_4_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2007.05.005"},{"key":"e_1_2_4_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/TA.0b013e3182041175"},{"key":"e_1_2_4_11_1","doi-asserted-by":"publisher","DOI":"10.1123\/jab.28.5.587"},{"key":"e_1_2_4_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2013.04.023"},{"key":"e_1_2_4_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-012-1585-7"},{"key":"e_1_2_4_14_1","doi-asserted-by":"publisher","DOI":"10.1186\/1749-799X-5-19"},{"key":"e_1_2_4_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jss.2012.04.014"}],"container-title":["Orthopaedic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fos.12101","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/os.12101","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,2]],"date-time":"2023-10-02T10:11:10Z","timestamp":1696241470000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/os.12101"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,5]]},"references-count":14,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2014,5]]}},"alternative-id":["10.1111\/os.12101"],"URL":"https:\/\/doi.org\/10.1111\/os.12101","archive":["Portico"],"relation":{},"ISSN":["1757-7853","1757-7861"],"issn-type":[{"value":"1757-7853","type":"print"},{"value":"1757-7861","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,5]]}}}