{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,3]],"date-time":"2023-10-03T06:16:16Z","timestamp":1696313776287},"reference-count":11,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2014,5,29]],"date-time":"2014-05-29T00:00:00Z","timestamp":1401321600000},"content-version":"vor","delay-in-days":28,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopaedic Surgery"],"published-print":{"date-parts":[[2014,5]]},"abstract":"<jats:sec><jats:title>Objective<\/jats:title><jats:p>To evaluate minimally invasive treatment of clavicular fractures with cannulated screw.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Data of 65 patients who had undergone minimally invasive treatment with cannulated screws for clavicular fractures from <jats:styled-content style=\"fixed-case\">A<\/jats:styled-content>pril 2009 to <jats:styled-content style=\"fixed-case\">O<\/jats:styled-content>ctober 2010 were retrospectively analyzed and compared with those of 65 patients with clavicular fractures who had been treated by the same surgeons with plates. In the study group, there were 41 males and 24 females, aged from 19\u201367 years (mean, 35.8 years). According to <jats:styled-content style=\"fixed-case\">C<\/jats:styled-content>raig's classification, there were 29 group 1 and 36 of group 2\u2010<jats:styled-content style=\"fixed-case\">II<\/jats:styled-content>. <jats:styled-content style=\"fixed-case\">N<\/jats:styled-content>eer scores were used to evaluate shoulder function and radiographs to assess fracture union.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The incision length was 4\u20135\u2009cm in the cannulated screw group (CSG) and 10\u201311\u2009cm in the reconstructive plate group (RPG). Radiographs showed bone union was achieved in both groups, the bone healing time being 13.2\u2009\u00b1\u20096.9 weeks in the CSG and 16.3\u2009\u00b1\u20098.7 weeks in the RPG. All patients were followed up for 6 to 20 months (average, 10.6 months). The average <jats:styled-content style=\"fixed-case\">N<\/jats:styled-content>eer score was 96.6\u2009\u00b1\u20093.4 in the CSG and 94.2\u2009\u00b1\u20095.8 in the RPG. In the CSG, screw loosening occurred in five, and fracture displacement in three. There was a significant difference in fracture healing time between two groups but not in <jats:styled-content style=\"fixed-case\">N<\/jats:styled-content>eer score.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Minimally invasive treatment of clavicular fractures with cannulated screws has the advantages of minimal invasion, short bone healing time, good clinical outcomes, and being relatively inexpensive.<\/jats:p><\/jats:sec>","DOI":"10.1111\/os.12108","type":"journal-article","created":{"date-parts":[[2014,5,30]],"date-time":"2014-05-30T02:31:50Z","timestamp":1401417110000},"page":"121-127","source":"Crossref","is-referenced-by-count":5,"title":["Minimally Invasive Treatment of Clavicular Fractures with Cannulated Screw"],"prefix":"10.1111","volume":"6","author":[{"given":"Jun\u2010zhan","family":"Sun","sequence":"first","affiliation":[{"name":"Department of Orthopaedics the 105th Hospital of People's Liberation Army  Hefei China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guo\u2010hai","family":"Zheng","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics the 105th Hospital of People's Liberation Army  Hefei China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ke\u2010yi","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics the 105th Hospital of People's Liberation Army  Hefei China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2014,5,29]]},"reference":[{"key":"e_1_2_5_2_1","first-page":"119","article-title":"Diagnosis, typing and treatment of clavicle fracture","volume":"23","author":"Wang Q","year":"2008","journal-title":"Zhongguo Gu Yu Guan Jie Sun Shang Za Zhi"},{"key":"e_1_2_5_3_1","first-page":"109","article-title":"Treating clavicle fracture with closed reduction and internal fixation by elastic threaded intramedullary screw","volume":"30","author":"Wang YQ","year":"2010","journal-title":"Zhonghua Gu Ke Za Zhi"},{"key":"e_1_2_5_4_1","first-page":"367","volume-title":"The Shoulder","author":"Craig EV","year":"1990"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197052060-00001"},{"key":"e_1_2_5_6_1","first-page":"327","article-title":"Anatomical and clinical application study on clavicle fracture treatment with small incision and minimally invasive transfixation","volume":"23","author":"Cui XG","year":"2005","journal-title":"Zhongguo Lin Chuang Jie Pou Xue Za Zhi"},{"key":"e_1_2_5_7_1","first-page":"199","article-title":"Reason analysis and response to failure after operation of clavicle fracture internal fixation","volume":"16","author":"Lu HY","year":"2010","journal-title":"Shi Yong Gu Ke Za Zhi"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0020-1383(99)00140-0"},{"key":"e_1_2_5_9_1","first-page":"474","article-title":"Analysis and response to postoperation complications of internal fixation of clavicle hook plate","volume":"22","author":"Wu XM","year":"2007","journal-title":"Zhong Hua Gu Ke Za Zhi"},{"key":"e_1_2_5_10_1","first-page":"474","article-title":"Treating tibial and fibular fracture with the combination of expandable intramedullary screw and elastic screw","volume":"22","author":"Zhou ZB","year":"2007","journal-title":"Zhongguo Gu Yu Guan Jie Sun Shang Za Zhi"},{"key":"e_1_2_5_11_1","first-page":"197","article-title":"Biomechanical property comparison between the two internal fixations in experimental clavicle fracture","volume":"25","author":"Zhang D","year":"2008","journal-title":"Guang Xi Yi Ke Da Xue Xue Bao"},{"key":"e_1_2_5_12_1","first-page":"11","volume-title":"Fracture and Dislocation","author":"Gustilo RB","year":"1993"}],"container-title":["Orthopaedic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fos.12108","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/os.12108","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,2]],"date-time":"2023-10-02T10:10:42Z","timestamp":1696241442000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/os.12108"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,5]]},"references-count":11,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2014,5]]}},"alternative-id":["10.1111\/os.12108"],"URL":"https:\/\/doi.org\/10.1111\/os.12108","archive":["Portico"],"relation":{},"ISSN":["1757-7853","1757-7861"],"issn-type":[{"value":"1757-7853","type":"print"},{"value":"1757-7861","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,5]]}}}