{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,28]],"date-time":"2026-01-28T21:27:24Z","timestamp":1769635644653,"version":"3.49.0"},"reference-count":35,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2014,9,1]],"date-time":"2014-09-01T00:00:00Z","timestamp":1409529600000},"content-version":"vor","delay-in-days":31,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopaedic Surgery"],"published-print":{"date-parts":[[2014,8]]},"abstract":"<jats:sec><jats:title>Objective<\/jats:title><jats:p>To systematically compare the fusion rate and safety of lumbar interbody fusion using one cage versus two cages for the treatment of degenerative lumbar spinal diseases.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>All randomized controlled trials (<jats:styled-content style=\"fixed-case\">RCTs<\/jats:styled-content>) and comparative observational studies written in English comparing the outcome of lumbar interbody fusion using one or two cages in patients with degenerative lumbar spinal diseases were identified by a comprehensive search of <jats:styled-content style=\"fixed-case\">PubMed<\/jats:styled-content> Central, <jats:styled-content style=\"fixed-case\">MEDLINE<\/jats:styled-content>, <jats:styled-content style=\"fixed-case\">EMBASE<\/jats:styled-content>, <jats:styled-content style=\"fixed-case\">BIOSIS<\/jats:styled-content> and the <jats:styled-content style=\"fixed-case\">C<\/jats:styled-content>ochrane <jats:styled-content style=\"fixed-case\">C<\/jats:styled-content>entral <jats:styled-content style=\"fixed-case\">R<\/jats:styled-content>egistry of <jats:styled-content style=\"fixed-case\">C<\/jats:styled-content>ontrolled <jats:styled-content style=\"fixed-case\">T<\/jats:styled-content>rials. An exhaustive electronic search up to July 2013. The quality of the methodology was assessed and relevant data retrieved independently by two reviewers, after which the resultant data were subjected to meta\u2010analysis. All meta\u2010analyses were performed using Review Manager 5.0, which is recommended and provided by the Cochrane Collaboration.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Our systematic search yielded 745 studies from the selected databases. After duplicate studies had been identified and the titles and abstracts screened, 736 studies were excluded because they were irrelevant to our topic. The full texts of the remaining nine potentially relevant references were comprehensively evaluated and four excluded for the following reasons: two studies involved co\u2010interventions and the other two lacked control groups. Two relevant <jats:styled-content style=\"fixed-case\">RCTs<\/jats:styled-content> and three comparative observational studies involving 384 patients and 501 spinal segments with at least one year follow\u2010up were identified. Analysis of the pooled data demonstrated no significant difference in fusion rate between the one\u2010cage and two\u2010cage groups. However, intraoperative blood loss and operating time were less and the complications rate lower in the one\u2010cage group.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>In patients with degenerative lumbar spinal diseases, lumbar interbody fusion using one cage has an equal fusion rate and is safer compared with using two cages. However, because this meta\u2010analysis had some limitations, more high quality <jats:styled-content style=\"fixed-case\">RCTs<\/jats:styled-content> are needed to strengthen the evidence.<\/jats:p><\/jats:sec>","DOI":"10.1111\/os.12119","type":"journal-article","created":{"date-parts":[[2014,9,1]],"date-time":"2014-09-01T12:26:12Z","timestamp":1409574372000},"page":"236-243","source":"Crossref","is-referenced-by-count":10,"title":["Comparison of One versus Two Cages in Lumbar Interbody Fusion for Degenerative Lumbar Spinal Disease: a Meta\u2010analysis"],"prefix":"10.1111","volume":"6","author":[{"given":"Jin","family":"Liu","sequence":"first","affiliation":[{"name":"Department of Spine Surgery Sichuan Orthopaedic Hospital"},{"name":"Department of Orthopaedics West China Hospital Sichuan University  Chengdu China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jing","family":"Tang","sequence":"additional","affiliation":[{"name":"Department of Radiology West China Hospital Sichuan University  Chengdu China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hao","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics West China Hospital Sichuan University  Chengdu China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2014,9]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.3171\/jns.1953.10.2.0154"},{"key":"e_1_2_6_3_1","first-page":"51","article-title":"Lesions of the intervertebral disks and their treatment by interbody fusion methods. The painful disk","volume":"27","author":"Cloward RB","year":"1963","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1529-9430(03)00004-4"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.BRS.0000076841.93570.78"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200006010-00017"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-003-0668-y"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000232714.72699.8e"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1227\/01.neu.0000430320.39870.f7"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200002150-00006"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-009-0917-6"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-011-1292-7"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.4055\/cios.2009.1.4.214"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e3181b1c99f"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-011-1873-8"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200212150-00003"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B10.21078"},{"key":"e_1_2_6_18_1","first-page":"337","article-title":"Are 2 cages needed with instrumented PLIF? A comparison of 1 versus 2 interbody cages in a military population","volume":"32","author":"Molinari RW","year":"2003","journal-title":"Am J Orthop"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1227\/01.NEU.0000335077.62599.F0"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e31818448a9"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/sim.1186"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0029-1224097"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.3171\/2012.5.SPINE111044"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.bsd.0000211251.59953.a4"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1097\/00024720-200310000-00006"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000160986.39171.4d"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199806010-00019"},{"issue":"2","key":"e_1_2_6_28_1","first-page":"186","article-title":"Posterior lumbar interbody fusion with cages: an independent review of 71 cases","volume":"91","author":"Agazzi S","year":"1999","journal-title":"J Neurosurg"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e3181d5fee3"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200209010-00029"},{"key":"e_1_2_6_31_1","doi-asserted-by":"publisher","DOI":"10.1097\/00002517-200012000-00014"},{"key":"e_1_2_6_32_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-011-1307-6"},{"key":"e_1_2_6_33_1","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20130523-33"},{"key":"e_1_2_6_34_1","doi-asserted-by":"publisher","DOI":"10.1097\/BSD.0b013e3182440162"},{"key":"e_1_2_6_35_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1988.03720110047033"},{"key":"e_1_2_6_36_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.309.6954.597"}],"container-title":["Orthopaedic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fos.12119","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/os.12119","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,2]],"date-time":"2023-10-02T11:12:20Z","timestamp":1696245140000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/os.12119"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,8]]},"references-count":35,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2014,8]]}},"alternative-id":["10.1111\/os.12119"],"URL":"https:\/\/doi.org\/10.1111\/os.12119","archive":["Portico"],"relation":{},"ISSN":["1757-7853","1757-7861"],"issn-type":[{"value":"1757-7853","type":"print"},{"value":"1757-7861","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,8]]}}}