{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T03:16:34Z","timestamp":1781061394781,"version":"3.54.1"},"reference-count":12,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2016,12,29]],"date-time":"2016-12-29T00:00:00Z","timestamp":1482969600000},"content-version":"vor","delay-in-days":58,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopaedic Surgery"],"published-print":{"date-parts":[[2016,11]]},"abstract":"<jats:p>A 56\u2010year\u2010old woman had fell over herself 4\u2009h prior to her presentation to our hospital. The diagnosis was a subtrochanteric fracture of the right femur (<jats:styled-content style=\"fixed-case\">AO<\/jats:styled-content>\u201032\u2010<jats:styled-content style=\"fixed-case\">A<\/jats:styled-content>3). The patient was placed in a supine position was set up on a fracture traction table after general anesthesia. The right leg was placed in abduction while the left leg was positioned so that there was flexion of the knee and hip joint. The <jats:styled-content style=\"fixed-case\">C<\/jats:styled-content>\u2010arm was placed on the left side. The surgical field was sterilized and draped. Deformity and external rotation are always present for this type of fracture, so the first step was to place a joystick in the proximal fragment to correct the external rotation. Then the perfect entry point could be defined by <jats:styled-content style=\"fixed-case\">K<\/jats:styled-content> wire. After inserting guide wire into the canal dreaming was followed. An appropriate nail was selected and inserted. The distal tip of the nail should be located in the cancellous bone. Before inserting the proximal lag screws into the femoral head, the external rotation of the proximal fragment must be corrected by the joystick. The traction was loosened and the distal fragment was pushed towards the proximal side so that the gap between the fragments disappeared. The affected leg was maintained in perfect alignment. Meanwhile, the distal locking screws were inserted using the free hand perfect circle technique.<\/jats:p>","DOI":"10.1111\/os.12291","type":"journal-article","created":{"date-parts":[[2016,12,29]],"date-time":"2016-12-29T12:40:27Z","timestamp":1483015227000},"page":"516-518","source":"Crossref","is-referenced-by-count":5,"title":["Surgical Technique for Subtrochanteric Fracture of Femur"],"prefix":"10.1111","volume":"8","author":[{"given":"Peng\u2010cheng","family":"Wang","sequence":"first","affiliation":[{"name":"Orthopaedic Trauma Service Center The Third Hospital of Hebei Medical University  Shijiazhuang China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong","family":"Ren","sequence":"additional","affiliation":[{"name":"Orthopaedic Trauma Service Center The Third Hospital of Hebei Medical University  Shijiazhuang China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chao\u2010hui","family":"Song","sequence":"additional","affiliation":[{"name":"Orthopaedic Trauma Service Center The Third Hospital of Hebei Medical University  Shijiazhuang China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bing","family":"Zhou","sequence":"additional","affiliation":[{"name":"Orthopaedic Trauma Service Center The Third Hospital of Hebei Medical University  Shijiazhuang China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2016,12,29]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0030-5898(03)00075-0"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.88B10.18023"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-200711000-00005"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1080\/17453670610046424"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.89B3.18146"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200006000-00005"},{"key":"e_1_2_6_8_1","first-page":"190","article-title":"Indirect reduction with sliding compression screw stabilization for subtrochanteric fractures","volume":"29","author":"Hsu YT","year":"2006","journal-title":"Chang Gung Med J"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000218760.19934.2b"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2005.12.022"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-200006000-00003"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2007.05.010"},{"key":"e_1_2_6_13_1","first-page":"351","article-title":"En bloc joystick reduction of a comminuted intra\u2010articular distal radius fracture: a technical trick","volume":"43","author":"Siegall E","year":"2014","journal-title":"Am J Orthop (Belle Mead NJ)"}],"container-title":["Orthopaedic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fos.12291","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fos.12291","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/os.12291","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,26]],"date-time":"2023-09-26T05:53:03Z","timestamp":1695707583000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/os.12291"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,11]]},"references-count":12,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2016,11]]}},"alternative-id":["10.1111\/os.12291"],"URL":"https:\/\/doi.org\/10.1111\/os.12291","archive":["Portico"],"relation":{},"ISSN":["1757-7853","1757-7861"],"issn-type":[{"value":"1757-7853","type":"print"},{"value":"1757-7861","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,11]]}}}