{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T06:10:26Z","timestamp":1791267026722,"version":"4.1.0"},"reference-count":15,"publisher":"Wiley","issue":"12","license":[{"start":{"date-parts":[[2022,10,21]],"date-time":"2022-10-21T00:00:00Z","timestamp":1666310400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81672181"],"award-info":[{"award-number":["81672181"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82072397"],"award-info":[{"award-number":["82072397"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Orthopaedic Surgery"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:sec><jats:title>Objective<\/jats:title><jats:p>The oscillating saw has some inherent disadvantages, such as notch formation and blood splash. The objective is to introduce the Gigli saw as a substitute osteotomy tool when oscillating saw malfunctions occur during surgery.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>During our retrospective study, 120 patients (120 hips) who underwent primary total hip arthroplasty (THA) because of femoral neck fracture, femoral head necrosis, developmental hip dysplasia (Crowe I), or primary osteoarthritis between October 2017 and April 2020 at our institute were included. Sixty patients (26 men and 34 women) with a mean age of 67.3\u2009years (\u00b115.1\u2009years) underwent femoral neck osteotomy using a Gigli saw. The other 60 patients (32 men and 28 women) with a mean age of 64.4\u2009years (\u00b118.8\u2009years) underwent femoral neck osteotomy using an oscillating saw. Intraoperative evaluations, including osteotomy time, osteotomy height, number of notch formations, and blood splash generation, were performed. Routine anteroposterior views of the pelvis and proximal femur were obtained for all patients after surgery.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The mean osteotomy times were 26.60\u2009\u00b1\u200914.80 s and 31.80\u2009\u00b1\u200914.20 s with the oscillating saw and Gigli saw, respectively (<jats:italic>t<\/jats:italic>\u00a0=\u00a01.964, <jats:italic>P<\/jats:italic>\u00a0=\u00a00.0519). The mean osteotomy heights were 1.26\u2009\u00b1\u20090.22 cm and 1.20\u2009\u00b1\u20090.14\u2009cm with the oscillating saw and Gigli saw, respectively (<jats:italic>t<\/jats:italic>\u00a0=\u00a01.782, <jats:italic>P<\/jats:italic>\u00a0=\u00a00.0773). The use of a Gigli saw did not result in bone notch formation or blood splash generation when multiple blood splashes were generated in the oscillating saw group. Postoperative radiographs showed no prostheses malposition in the Gigli saw and oscillating saw groups.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The Gigli saw has various advantages and can be a substitute tool for femoral neck osteotomy during THA when oscillating saw malfunctions occur.<\/jats:p><\/jats:sec>","DOI":"10.1111\/os.13555","type":"journal-article","created":{"date-parts":[[2022,10,21]],"date-time":"2022-10-21T08:40:11Z","timestamp":1666341611000},"page":"3277-3282","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Use of a Gigli Saw as a Substitute Osteotomy Tool When Oscillating Saw Malfunctions Occur During Hip Arthroplasty"],"prefix":"10.1111","volume":"14","author":[{"given":"Keyu","family":"Kong","sequence":"first","affiliation":[{"name":"Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongyun","family":"Chang","sequence":"additional","affiliation":[{"name":"Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4969-8070","authenticated-orcid":false,"given":"Degang","family":"Yu","sequence":"additional","affiliation":[{"name":"Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuanqing","family":"Mao","sequence":"additional","affiliation":[{"name":"Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8341-0165","authenticated-orcid":false,"given":"Yiming","family":"Zeng","sequence":"additional","affiliation":[{"name":"Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mengning","family":"Yan","sequence":"additional","affiliation":[{"name":"Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0312-7539","authenticated-orcid":false,"given":"Zanjing","family":"Zhai","sequence":"additional","affiliation":[{"name":"Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huiwu","family":"Li","sequence":"additional","affiliation":[{"name":"Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2022,10,21]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.maturitas.2013.04.011"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0001-2092(06)60586-3"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(18)31777-X"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(07)60457-7"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2008.09.021"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.102B10.BJJ-2019-1602.R2"},{"issue":"5","key":"e_1_2_7_8_1","first-page":"678","article-title":"The risks of splash injury when using power tools during orthopaedic surgery: a prospective study","volume":"74","author":"Alani A","year":"2008","journal-title":"Acta Orthop Belg"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2019.07.040"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2017.09.032"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2019.06.062"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.101B10.BJJ-2018-1596.R1"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1177\/1120700019849911"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.91B8.22079"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jot.2018.06.002"},{"issue":"3","key":"e_1_2_7_16_1","first-page":"375","article-title":"A quantitative assessment of facial protection systems in elective hip arthroplasty","volume":"77","author":"Hirpara KM","year":"2011","journal-title":"Acta Orthop Belg"}],"container-title":["Orthopaedic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/os.13555","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/os.13555","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/os.13555","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,19]],"date-time":"2023-08-19T22:40:13Z","timestamp":1692484813000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/os.13555"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,21]]},"references-count":15,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["10.1111\/os.13555"],"URL":"https:\/\/doi.org\/10.1111\/os.13555","archive":["Portico"],"relation":{},"ISSN":["1757-7853","1757-7861"],"issn-type":[{"value":"1757-7853","type":"print"},{"value":"1757-7861","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,21]]},"assertion":[{"value":"2021-11-13","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-09-15","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-10-21","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}