{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T17:18:42Z","timestamp":1793726322191,"version":"4.6.1"},"reference-count":20,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2022,11,16]],"date-time":"2022-11-16T00:00:00Z","timestamp":1668556800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Orthopaedic Surgery"],"published-print":{"date-parts":[[2023,1]]},"abstract":"<jats:sec><jats:title>Objective<\/jats:title><jats:p>Intraoperative O\u2010arm navigation systems improve the accuracy of spinal instrumentation placement. However, deviation of the pedicle screw from the guide line might occur. The aim of the present study was to explore the causes of and countermeasures for the drift phenomenon during pedicle screw implantation with the aid of an O\u2010arm three\u2010dimensional navigation system in spinal deformity surgery.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This was a retrospective analysis of 341 patients with spinal deformity who underwent O\u2010arm navigation system\u2010assisted pedicle screw placement from July 2015 to June 2019. The patient's general condition, Cobb angle, apical vertebra position, softness index, spinal release status, fixed reference frame position, and distance between the navigation vertebral body and the reference frame were collected and compared by independent\u2010samples <jats:italic>t<\/jats:italic> test or Pearson's chi\u2010square analysis. The potential risk factors for the drift phenomenon were identified using binary logistic regression analysis.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The drift phenomenon occurred in 57 patients during the first navigation\u2010assisted pedicle screw placement, for an incidence of 16.7% (57\/341). There were significant differences in factors such as the apical vertebra position, softness index, spinal release status, and distance between the vertebral body and the reference frame when the drift phenomenon occurred (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.05). Binary logistic regression analysis showed that the softness index, spinal release status, and distance between the vertebral body and the reference frame when drifting occurred were independent risk factors for the drift phenomenon during O\u2010arm navigation\u2010assisted pedicle screw placement.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>During the use of an O\u2010arm navigation system to assist with pedicle screw placement, pedicle screws should not be placed away from the reference frame, and spinal osteotomy and release should be performed after pedicle screw placement. In addition, the accuracy of O\u2010arm navigation\u2010assisted pedicle screw placement will be affected more in those with larger softness indices.<\/jats:p><\/jats:sec>","DOI":"10.1111\/os.13557","type":"journal-article","created":{"date-parts":[[2022,11,17]],"date-time":"2022-11-17T05:39:33Z","timestamp":1668663573000},"page":"118-123","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Risk Factors for the Drift Phenomenon in O\u2010arm Navigation\u2010Assisted Pedicle Screw Placement during Spinal Deformity Surgery"],"prefix":"10.1111","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2847-952X","authenticated-orcid":false,"given":"Jianquan","family":"Zhao","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Shanghai Changzheng Hospital Second Military Medical University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heng","family":"Jiang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Shanghai Changzheng Hospital Second Military Medical University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yingjie","family":"Zhuge","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rui","family":"Gao","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Shanghai Changzheng Hospital Second Military Medical University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ce","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Shanghai Changzheng Hospital Second Military Medical University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Ma","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Shanghai Changzheng Hospital Second Military Medical University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3936-7550","authenticated-orcid":false,"given":"Xuhui","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Shanghai Changzheng Hospital Second Military Medical University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2022,11,16]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.J.00678"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-012-2360-6"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-011-2011-3"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.4184\/asj.2014.8.3.331"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1093\/ons\/opx142"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2021.12.006"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1177\/2309499016684090"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2016.11.133"},{"key":"e_1_2_6_10_1","first-page":"237","article-title":"Asymmetric cross sectional area size of the psoas muscle seems to be a key feature in patients with L4\u20105 lumbar disc herniations","volume":"32","author":"Batcik OE","year":"2022","journal-title":"Turk Neurosurg"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-008-0795-6"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2017.02.038"},{"key":"e_1_2_6_13_1","first-page":"34","article-title":"Anatomic and technical considerations of pedicle screw fixation","author":"Weinstein JN","year":"1992","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_2_6_14_1","article-title":"Pedicle screw placement assisted by 3D imaging (O\u2010arm system with StealthStation\u00ae software) versus free\u2010hand technique for multilevel posterior thoracolumbar fusion","volume":"29","author":"Noshchenko A","year":"2018","journal-title":"Curr Orthop Pract"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-010-1683-4"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.3171\/2012.5.SPINE11399"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-015-4012-0"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.3171\/2014.1.FOCUS13499"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-016-3353-6"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1007\/s005860000146"},{"issue":"32","key":"e_1_2_6_21_1","first-page":"2668","article-title":"The reliability of preoperative supine radiographs to predict the amount of curve flexibility in adolescent idiopathic scoliosis","volume":"2007","author":"Cheh G","year":"1976","journal-title":"Spine"}],"container-title":["Orthopaedic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/os.13557","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/os.13557","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/os.13557","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,19]],"date-time":"2023-08-19T10:35:20Z","timestamp":1692441320000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/os.13557"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,16]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023,1]]}},"alternative-id":["10.1111\/os.13557"],"URL":"https:\/\/doi.org\/10.1111\/os.13557","archive":["Portico"],"relation":{},"ISSN":["1757-7853","1757-7861"],"issn-type":[{"value":"1757-7853","type":"print"},{"value":"1757-7861","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,16]]},"assertion":[{"value":"2022-03-20","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-09-16","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-11-16","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}