{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,8]],"date-time":"2026-05-08T19:56:50Z","timestamp":1778270210247,"version":"3.51.4"},"reference-count":13,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2012,12,13]],"date-time":"2012-12-13T00:00:00Z","timestamp":1355356800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2013,3]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>\n                      <jats:italic>Outpatient ambulatory cardiac rhythm monitoring is a routine part of the management of patients with paroxysmal atrial fibrillation (AF). Current systems are limited by patient convenience and practicality<\/jats:italic>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      <jats:italic>We compared the Zio<\/jats:italic>\n                      <jats:sup>\u00ae<\/jats:sup>\n                      <jats:italic>Patch, a single\u2010use, noninvasive waterproof long\u2010term continuous monitoring patch, with a 24\u2010hour Holter monitor in 74 consecutive patients with paroxysmal AF referred for Holter monitoring for detection of arrhythmias<\/jats:italic>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      <jats:italic>The Zio<\/jats:italic>\n                      <jats:sup>\u00ae<\/jats:sup>\n                      <jats:italic>Patch was well tolerated, with a mean monitoring period of 10.8 \u00b1 2.8 days (range 4\u201314 days). Over a 24\u2010hour period, there was excellent agreement between the Zio<\/jats:italic>\n                      <jats:sup>\u00ae<\/jats:sup>\n                      <jats:italic>Patch and Holter for identifying AF events and estimating AF burden. Although there was no difference in AF burden estimated by the Zio<\/jats:italic>\n                      <jats:sup>\u00ae<\/jats:sup>\n                      <jats:italic>Patch and the Holter monitor, AF events were identified in 18 additional individuals, and the documented pattern of AF (persistent or paroxysmal) changed in 21 patients after Zio<\/jats:italic>\n                      <jats:sup>\u00ae<\/jats:sup>\n                      <jats:italic>Patch monitoring. Other clinically relevant cardiac events recorded on the Zio<\/jats:italic>\n                      <jats:sup>\u00ae<\/jats:sup>\n                      <jats:italic>Patch after the first 24 hours of monitoring, including symptomatic ventricular pauses, prompted referrals for pacemaker placement or changes in medications. As a result of the findings from the Zio<\/jats:italic>\n                      <jats:sup>\u00ae<\/jats:sup>\n                      <jats:italic>Patch, 28.4% of patients had a change in their clinical management<\/jats:italic>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>\n                      <jats:italic>The Zio<\/jats:italic>\n                      <jats:sup>\u00ae<\/jats:sup>\n                      <jats:italic>Patch was well tolerated, and allowed significantly longer continuous monitoring than a Holter, resulting in an improvement in clinical accuracy, the detection of potentially malignant arrhythmias, and a meaningful change in clinical management. Further studies are necessary to examine the long\u2010term impact of the use of the Zio<\/jats:italic>\n                      <jats:sup>\u00ae<\/jats:sup>\n                      <jats:italic>Patch in AF management<\/jats:italic>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/pace.12053","type":"journal-article","created":{"date-parts":[[2012,12,13]],"date-time":"2012-12-13T15:55:22Z","timestamp":1355414122000},"page":"328-333","source":"Crossref","is-referenced-by-count":163,"title":["Use of a Noninvasive Continuous Monitoring Device in the Management of Atrial Fibrillation: A Pilot Study"],"prefix":"10.1111","volume":"36","author":[{"given":"MICHAEL A.","family":"ROSENBERG","sequence":"first","affiliation":[{"name":"Division of Electrophysiology, Beth Israel Deaconess Medical Center Harvard Medical School  Boston Massachusetts"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MICHELLE","family":"SAMUEL","sequence":"additional","affiliation":[{"name":"Division of Electrophysiology, Beth Israel Deaconess Medical Center Harvard Medical School  Boston Massachusetts"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"AMIT","family":"THOSANI","sequence":"additional","affiliation":[{"name":"Division of Electrophysiology, West Penn Allegheny Health System Temple University  Pittsburgh Pennsylvania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"PETER J.","family":"ZIMETBAUM","sequence":"additional","affiliation":[{"name":"Division of Electrophysiology, Beth Israel Deaconess Medical Center Harvard Medical School  Boston Massachusetts"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2012,12,13]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1136\/heart.86.3.284"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1524-4733.2006.00124.x"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2003.08.027"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1105575"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-128-11-199806010-00002"},{"key":"e_1_2_5_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2011.05.008"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2009.02357.x"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2011.11.058"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcnurse.2009.09.002"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(92)90530-Z"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(94)00560-D"},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.106.478685"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.109.849638"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fpace.12053","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/pace.12053","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,30]],"date-time":"2023-10-30T11:52:28Z","timestamp":1698666748000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/pace.12053"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,12,13]]},"references-count":13,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2013,3]]}},"alternative-id":["10.1111\/pace.12053"],"URL":"https:\/\/doi.org\/10.1111\/pace.12053","archive":["Portico"],"relation":{"has-review":[{"id-type":"doi","id":"10.3410\/f.717987423.793474360","asserted-by":"object"}]},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,12,13]]}}}