{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T12:47:34Z","timestamp":1787230054901,"version":"build-2736575974"},"reference-count":17,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2013,11,11]],"date-time":"2013-11-11T00:00:00Z","timestamp":1384128000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"Frederik Meijer Heart & Vascular Institute","award":["Internal Grant"],"award-info":[{"award-number":["Internal Grant"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2014,1]]},"abstract":"<jats:sec><jats:title>Objective<\/jats:title><jats:p>The purpose of our study was to determine if the rate of lead\u2010related complications was increased with the Medtronic CapSureFix MRI\u2122 SureScan\u2122 5086 MRI pacing lead (5086; Medtronic Inc., Minneapolis, MN, USA) compared to the previous generation of Medtronic CapSureFix Novus\u2122 5076 pacing lead (5076).<\/jats:p><\/jats:sec><jats:sec><jats:title>Background<\/jats:title><jats:p>The 5086 lead is a newly introduced active\u2010fixation pacemaker lead designed to be used conditionally in a magnetic resonance (MR) scanner. This lead has specific design changes compared to the previous generation of 5076 pacing leads.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This study was a retrospective case control study of 65 consecutive patients implanted with two 5086 leads compared to 92 consecutive control patients implanted with two 5076 leads over a 14\u2010month period at a high\u2010volume tertiary care hospital.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Pericarditis, pericardial effusion, cardiac tamponade, or death within 30 days of implant were seen in eight patients from the 5086 cohort and two from the 5076 cohort (odds ratio 6.3, 95% confidence interval 1.3\u201330.8, P = 0.02). Lead dislodgement occurred in four of the 5086 patients and in none of the 5076 patients (P &lt; 0.03).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>In a high\u2010volume center, the incidence of pericarditis, cardiac perforation, tamponade, death, and lead dislodgement was significantly higher with the MR\u2010conditional Medtronic 5086 lead when compared to the previous generation Medtronic 5076 lead.<\/jats:p><\/jats:sec>","DOI":"10.1111\/pace.12293","type":"journal-article","created":{"date-parts":[[2013,11,11]],"date-time":"2013-11-11T21:12:48Z","timestamp":1384204368000},"page":"4-10","source":"Crossref","is-referenced-by-count":25,"title":["Cardiac Perforation and Lead Dislodgement after Implantation of a MR\u2010Conditional Pacing Lead: A Single\u2010Center Experience"],"prefix":"10.1111","volume":"37","author":[{"given":"DARRYL A.","family":"ELMOUCHI","sequence":"first","affiliation":[{"name":"Frederik Meijer Heart and Vascular Institute Spectrum Health  Grand Rapids Michigan"},{"name":"Department of Internal Medicine, Michigan State University College of Human Medicine  Grand Rapids Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"SHELLY","family":"ROSEMA","sequence":"additional","affiliation":[{"name":"Frederik Meijer Heart and Vascular Institute Spectrum Health  Grand Rapids Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"STACIE M.","family":"VANOOSTERHOUT","sequence":"additional","affiliation":[{"name":"Frederik Meijer Heart and Vascular Institute Spectrum Health  Grand Rapids Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"MOHSIN","family":"KHAN","sequence":"additional","affiliation":[{"name":"Grand Rapids Medical Education Partners  Grand Rapids Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ALAN T.","family":"DAVIS","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Michigan State University College of Human Medicine  Grand Rapids Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ANDRE J.","family":"GAURI","sequence":"additional","affiliation":[{"name":"Frederik Meijer Heart and Vascular Institute Spectrum Health  Grand Rapids Michigan"},{"name":"Department of Internal Medicine, Michigan State University College of Human Medicine  Grand Rapids Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"BOHUSLAV","family":"FINTA","sequence":"additional","affiliation":[{"name":"Frederik Meijer Heart and Vascular Institute Spectrum Health  Grand Rapids Michigan"},{"name":"Department of Internal Medicine, Michigan State University College of Human Medicine  Grand Rapids Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ALAN K.","family":"WOELFEL","sequence":"additional","affiliation":[{"name":"Frederik Meijer Heart and Vascular Institute Spectrum Health  Grand Rapids Michigan"},{"name":"Department of Internal Medicine, Michigan State University College of Human Medicine  Grand Rapids Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"NAGIB T.","family":"CHALFOUN","sequence":"additional","affiliation":[{"name":"Frederik Meijer Heart and Vascular Institute Spectrum Health  Grand Rapids Michigan"},{"name":"Department of Internal Medicine, Michigan State University College of Human Medicine  Grand Rapids Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2013,11,11]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2010.04.043"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2008.10.021"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2010.02.020"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2011.273"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1186\/1745-6215-9-68"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2013.01.022"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00399-011-0161-y"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2005.40003.x"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2011.12.014"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1540-8167.2003.02305.x"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.73.6.571"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1253\/circj.CJ-12-0707"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1186\/1532-429X-13-63"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2010.10.002"},{"key":"e_1_2_7_16_1","first-page":"2340","article-title":"Clinical and electrical performance of currently available MRI\u2010safe pacing systems. Do all devices perform in the same way?","volume":"67","author":"Forleo GB","year":"2012","journal-title":"Int J Cardiol"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2012.07.064"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2002.01153.x"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fpace.12293","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/pace.12293","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,28]],"date-time":"2023-10-28T09:10:53Z","timestamp":1698484253000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/pace.12293"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,11,11]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2014,1]]}},"alternative-id":["10.1111\/pace.12293"],"URL":"https:\/\/doi.org\/10.1111\/pace.12293","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,11,11]]}}}