{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T01:53:08Z","timestamp":1792029188280,"version":"4.4.0"},"reference-count":18,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2016,3,31]],"date-time":"2016-03-31T00:00:00Z","timestamp":1459382400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2016,5]]},"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Left atrial ablation can be accompanied by discomfort or pain. The purpose of this study was to systematically compare pain reactions during ablation of atrial fibrillation under deep sedation with cryothermal and radiofrequency energy.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods and Results<\/jats:title><jats:p>Circumferential ablation was performed in patients with atrial fibrillation using either radiofrequency (RF) or cryoenergy. Deep sedation was achieved with a combination of propofol and midazolam. Pain reactions were counted and painful ablation sites located. To determine the severity of the pain reactions a Face, Legs, Activity, Cry, Consolability (FLACC) Behavioral Pain Assessment Scale was used: 79 patients (53 RF\u2010 vs 26 Cryoablations) were included. A total of 92% of patients treated with RF energy showed \u22651 pain reaction during the procedure compared to only 13% in the cryoenergy group (&lt;0.001). The total number of pain reactions was significantly higher in the RF energy group (3.6 \u00b1 4.7 vs1.3 \u00b1 0.6, P = 0.005). Determination of painful sites was performed in the RF group only. Pain reactions were significantly more often observed during RF application left superior pulmonary vein (LSPV) ostium compared to other left atrial ablation sites (Total FLACC Score 2.8 \u00b1 0.6 LSPV, 1.4 \u00b1 0.4 left inferior pulmonary vein [P = 0.009], 1.4 \u00b1 0.3 right superior pulmonary vein [P = 0.044], 1.1 \u00b1 0.3 right inferior pulmonary vein [P = 0.032]).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Our results show that despite deep sedation pain reactions often occur during RF ablation. Knowledge of areas with more frequent pain reactions may help electrophysiologists to reduce pain reactions and related patient movements. Ablation with cryoenergy was significantly less painful compared to ablation with RF energy. Cryoablation therefore may be considered for patients at a higher risk for anesthesia\u2010related complications.<\/jats:p><\/jats:sec>","DOI":"10.1111\/pace.12840","type":"journal-article","created":{"date-parts":[[2016,3,1]],"date-time":"2016-03-01T11:28:06Z","timestamp":1456831686000},"page":"452-457","source":"Crossref","is-referenced-by-count":31,"title":["Pain Reactions during Pulmonary Vein Isolation under Deep Sedation: Cryothermal versus Radiofrequency Ablation"],"prefix":"10.1111","volume":"39","author":[{"given":"PHILIPP","family":"ATTANASIO","sequence":"first","affiliation":[{"name":"Department of Cardiology, Charit\u00e9 \u2010 Universitaetsmedizin Berlin Campus Virchow\u2010Klinikum  Berlin Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"MARTIN","family":"HUEMER","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Charit\u00e9 \u2010 Universitaetsmedizin Berlin Campus Virchow\u2010Klinikum  Berlin Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ABDUL","family":"SHOKOR PARWANI","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Charit\u00e9 \u2010 Universitaetsmedizin Berlin Campus Virchow\u2010Klinikum  Berlin Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"LEIF\u2010HENDRIK","family":"BOLDT","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Charit\u00e9 \u2010 Universitaetsmedizin Berlin Campus Virchow\u2010Klinikum  Berlin Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ANDREAS","family":"M\u00dcGGE","sequence":"additional","affiliation":[{"name":"Cardiovascular Center, St. Josef\u2010Hospital Ruhr\u2010University Bochum  Bochum Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"WILHELM","family":"HAVERKAMP","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Charit\u00e9 \u2010 Universitaetsmedizin Berlin Campus Virchow\u2010Klinikum  Berlin Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ALEXANDER","family":"WUTZLER","sequence":"additional","affiliation":[{"name":"Cardiovascular Center, St. Josef\u2010Hospital Ruhr\u2010University Bochum  Bochum Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2016,3,31]]},"reference":[{"key":"e_1_2_7_2_1","first-page":"32","article-title":"Update worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation","volume":"3","author":"Cappato R","year":"2010","journal-title":"Circulation"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2011.03260.x"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2009.02.022"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-5273(02)00376-5"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/jce.12001"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1408288"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eus261"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2010.02858.x"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.5603\/CJ.a2013.0153"},{"key":"e_1_2_7_11_1","unstructured":"American Society of Anesthesiologists (ASA): Standards for Basic Anesthetic Monitoring. Continuum of Depth of Sedation: Definition of General Anesthesia and Levels of Sedation\/Analgesia. Available at:http:\/\/www.asahq.org\/For\u2010Members\/Standards\u2010Guidelines\u2010and\u2010Statements.aspx(accessed November 12 2015)."},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-008-9209-2"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.acvd.2010.06.004"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eur036"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-009-9447-y"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2007.00975.x"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2007.00842.x"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1152\/ajpregu.00183.2004"},{"key":"e_1_2_7_19_1","first-page":"293","article-title":"The FLACC: A behavioral scale for scoring postoperative pain in young children","volume":"23","author":"Merkel SI","year":"1997","journal-title":"Pediatr Nurs"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fpace.12840","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/pace.12840","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,26]],"date-time":"2023-09-26T16:59:40Z","timestamp":1695747580000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/pace.12840"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,3,31]]},"references-count":18,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2016,5]]}},"alternative-id":["10.1111\/pace.12840"],"URL":"https:\/\/doi.org\/10.1111\/pace.12840","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,3,31]]}}}