{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,6]],"date-time":"2023-10-06T08:19:46Z","timestamp":1696580386578},"reference-count":11,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2017,3,23]],"date-time":"2017-03-23T00:00:00Z","timestamp":1490227200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2017,5]]},"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Treatment of left ventricular electrode dislocation and phrenic nerve stimulation remains an issue in the era of new electrode designs.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Safety and efficacy of minimal invasive lead repositioning and pocket opening reposition procedures were evaluated between December 2005 and December 2012 at our center.<\/jats:p><jats:p>Minimal invasive method was developed and widely utilized at our center to treat phrenic nerve stimulation. The distally positioned left ventricular lead is looped around by a deflectable catheter in the right atrium introduced from the femoral vein access and then pulled back. Coronary stent implantation was used afterwards for lead stabilization in some patients.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>42 minimal invasive and 48 electrode repositions with pacemaker pocket opening were performed at 77 patients for left ventricular lead problems. Minimal invasive reposition could be carried out successfully in 69% of (29 patients) cases. Note that in 14.3% of the cases (six patients) minimal invasive procedures were acutely unsuccessful and crossover was necessary. In 16.6% of the cases (seven patients) lead issues were noted later during follow\u2010up. Opening of the pocket could be carried out successfully in 81.2% (39 patients) and was unsuccessful acutely in 6.25% (three patients). Repeated dislocation was noticed, 12.5%, in this group (six patients). Complication during minimal invasive procedures was electrode injury in one case. Pocket openings were associated with several complications: atrial fibrillation, pericardial effusion, fever, hematoma, and right ventricular electrode dislodgement.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Minimal invasive procedure\u2014as the first line approach\u2014is safe and feasible for left ventricular electrode repositioning in selected cases.<\/jats:p><\/jats:sec>","DOI":"10.1111\/pace.13068","type":"journal-article","created":{"date-parts":[[2017,2,27]],"date-time":"2017-02-27T11:27:18Z","timestamp":1488194838000},"page":"488-493","source":"Crossref","is-referenced-by-count":1,"title":["Minimal Invasive Left Ventricular Lead Repositioning is Safe and Effective in Distal Left Ventricular Lead Positions"],"prefix":"10.1111","volume":"40","author":[{"given":"ISTV\u00c1N","family":"OSZTHEIMER","sequence":"first","affiliation":[{"name":"Semmelweis University Heart and Vascular Center  Budapest Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"SZABOLCS","family":"SZIL\u00c1GYI","sequence":"additional","affiliation":[{"name":"Semmelweis University Heart and Vascular Center  Budapest Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ZSUZSANNA","family":"PONGOR","sequence":"additional","affiliation":[{"name":"Semmelweis University Heart and Vascular Center  Budapest Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ENDRE","family":"ZIMA","sequence":"additional","affiliation":[{"name":"Semmelweis University Heart and Vascular Center  Budapest Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"LEVENTE","family":"MOLN\u00c1R","sequence":"additional","affiliation":[{"name":"Semmelweis University Heart and Vascular Center  Budapest Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"TAM\u00c1S","family":"TAHIN","sequence":"additional","affiliation":[{"name":"Semmelweis University Heart and Vascular Center  Budapest Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B\u00c9LA","family":"MERKELY","sequence":"additional","affiliation":[{"name":"Semmelweis University Heart and Vascular Center  Budapest Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L\u00c1SZL\u00d3","family":"GELL\u00c9R","sequence":"additional","affiliation":[{"name":"Semmelweis University Heart and Vascular Center  Budapest Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2017,3,23]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/pace.12664"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehq497"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eun207"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2007.00722.x"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eut300"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2011.01.016"},{"key":"e_1_2_6_8_1","first-page":"533","article-title":"Additional electrodes on the Quartet\u2122 LV lead provide more programmable pacing options than bipolar and tripolar equivalents","volume":"16","author":"O'Donnell D","year":"2016","journal-title":"Europace"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eus237"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2014.12.019"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2014.04.020"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euv272"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fpace.13068","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/pace.13068","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,5]],"date-time":"2023-10-05T13:18:17Z","timestamp":1696511897000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/pace.13068"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3,23]]},"references-count":11,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2017,5]]}},"alternative-id":["10.1111\/pace.13068"],"URL":"https:\/\/doi.org\/10.1111\/pace.13068","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,3,23]]}}}