{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T11:32:30Z","timestamp":1740137550688,"version":"3.37.3"},"reference-count":12,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2018,4,15]],"date-time":"2018-04-15T00:00:00Z","timestamp":1523750400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2018,5]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>The management of patients explanted for implantable converter defibrillator (ICD) infections may be complex when anti\u2010bradycardia pacing and tachyarrhythmia protection are needed. We aimed to test the efficacy and safety of a conventional ICD externally connected to a transvenous dual\u2010coil lead as bridging therapy before the reimplantation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods and results<\/jats:title><jats:p>We enrolled seven patients explanted for ICD infections and needed prolonged antibiotic therapy in two high\u2010volume hospitals in Italy and treated them with a passive\u2010can external ICD for a mean of 13 (4\u201330) days before reimplant. One patient experienced an electrical storm, efficaciously recognized by the external ICD and treated with antitachycardia pacing and shocks. On\u2010demand pacing was granted for all the patients. No device\u2010related complications were reported.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>An external ICD seems safe and efficacious as a bridge to reimplant in patients explanted for ICD infections.<\/jats:p><\/jats:sec>","DOI":"10.1111\/pace.13320","type":"journal-article","created":{"date-parts":[[2018,3,8]],"date-time":"2018-03-08T18:22:38Z","timestamp":1520533358000},"page":"532-535","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["External implantable defibrillator as a bridge to reimplant after explant for infection: Experience from two centers"],"prefix":"10.1111","volume":"41","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7517-0771","authenticated-orcid":false,"given":"Gabriele","family":"Dell'Era","sequence":"first","affiliation":[{"name":"Division of Cardiology, University of Eastern Piedmont Maggiore della Carit\u00e0 Hospital  Novara Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3617-2739","authenticated-orcid":false,"given":"Matteo","family":"Ziacchi","sequence":"additional","affiliation":[{"name":"Institute of Cardiology, University of Bologna S. Orsola\u2010Malpighi University Hospital  Bologna Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eleonora","family":"Prenna","sequence":"additional","affiliation":[{"name":"Division of Cardiology, University of Eastern Piedmont Maggiore della Carit\u00e0 Hospital  Novara Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Igor","family":"Diemberger","sequence":"additional","affiliation":[{"name":"Institute of Cardiology, University of Bologna S. Orsola\u2010Malpighi University Hospital  Bologna Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marco","family":"Varalda","sequence":"additional","affiliation":[{"name":"Division of Cardiology, University of Eastern Piedmont Maggiore della Carit\u00e0 Hospital  Novara Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cristian","family":"Martignani","sequence":"additional","affiliation":[{"name":"Institute of Cardiology, University of Bologna S. Orsola\u2010Malpighi University Hospital  Bologna Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Federico","family":"Guerra","sequence":"additional","affiliation":[{"name":"Cardiology and Arrhythmology Clinic, Department of Biomedical Sciences and Public Health Marche Polytechnic University  Ancona Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mauro","family":"Biffi","sequence":"additional","affiliation":[{"name":"Institute of Cardiology, University of Bologna S. Orsola\u2010Malpighi University Hospital  Bologna Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eraldo","family":"Occhetta","sequence":"additional","affiliation":[{"name":"Division of Cardiology, University of Eastern Piedmont Maggiore della Carit\u00e0 Hospital  Novara Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2018,4,15]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.110.976076"},{"key":"e_1_2_7_3_1","first-page":"1726","article-title":"External implantable defibrillator as a bridge to reimplant after implantable cardioverter\u2010defibrillator explant","volume":"17","author":"Dell'Era G","year":"2015","journal-title":"Europace"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2017.09.001"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.95.8.2098"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/pace.12175"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2006.00454.x"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eut045"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.113.003042"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehu112"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2009.02590.x"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2003.00311.x"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2010.04.016"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fpace.13320","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/pace.13320","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T23:47:49Z","timestamp":1695512869000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/pace.13320"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,4,15]]},"references-count":12,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018,5]]}},"alternative-id":["10.1111\/pace.13320"],"URL":"https:\/\/doi.org\/10.1111\/pace.13320","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"type":"print","value":"0147-8389"},{"type":"electronic","value":"1540-8159"}],"subject":[],"published":{"date-parts":[[2018,4,15]]},"assertion":[{"value":"2018-01-16","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-02-25","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-04-15","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}