{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T14:29:05Z","timestamp":1768832945923,"version":"3.49.0"},"reference-count":25,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2019,3,5]],"date-time":"2019-03-05T00:00:00Z","timestamp":1551744000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2019,4]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Introduction<\/jats:title><jats:p>The longevity of a cardiac implantable electronic device (CIED) depends on how quickly the powers consumed by the device's functions exhaust its usable battery energy. A mathematical model for CIED power consumptions was developed and validated against longevity data from manufacturers.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The programmable parameters for the Resonate X4 cardiac resynchronization therapy defibrillators (CRT\u2010Ds) on the Boston Scientific (St. Paul, MN, USA) online longevity calculator were designated as independent terms in the sum for the total power consumption. The reciprocal of longevity was plotted against variations in these terms. Linear and nonlinear regression analyses were used to fit the plots. The power consumed by pacing was theoretically derived and used as the calibrating tool for estimating the powers consumed by other functions and the usable battery energy. The same methodology was applied to the longevity data of other manufacturers\u2019 CRT\u2010Ds.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Single chamber 100% pacing at 60\u00a0beats\/min, 2.5 V, 0.4\u00a0ms, 500 \u03a9 consumes\u00a0\u2248\u00a0144 J\/year. Shock therapy is 45\u201385% energy efficient. Multichamber pacing modes and maintaining readiness to pace a chamber consume power even if no pacing is delivered. Switching voltage regulation is theoretically more energy efficient than linear voltage regulation for powering pacing.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The powers consumed by therapy functions are dictated by the patient's clinical needs, but healthcare professionals can extend device longevity by switching off dormant functions and simplifying the pacing mode. Choosing a device model with large usable battery energy, low background power, and energy efficient pacing and shock therapy for implantation will increase the probability of a long service lifespan.<\/jats:p><\/jats:sec>","DOI":"10.1111\/pace.13642","type":"journal-article","created":{"date-parts":[[2019,2,26]],"date-time":"2019-02-26T06:12:42Z","timestamp":1551161562000},"page":"407-422","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Longevity decoded: Insights from power consumption analyses into device construction and their clinical implications"],"prefix":"10.1111","volume":"42","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0030-9326","authenticated-orcid":false,"given":"Ernest W.","family":"Lau","sequence":"first","affiliation":[{"name":"Department of Cardiology Royal Victoria Hospital  Belfast Northern Ireland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2019,3,5]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/jce.12990"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eut133"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.110.976076"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2011.03257.x"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.115.002813"},{"key":"e_1_2_8_7_1","first-page":"1013","article-title":"Recurrent implantable cardioverter\u2010defibrillator replacement is associated with an increasing risk of pocket\u2010related complications","volume":"33","author":"Borleffs CJ","year":"2010","journal-title":"Pacing Clin Electrophysiol"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euv436"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2018.07.029"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2009.09.013"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00392-012-0493-6"},{"key":"e_1_2_8_12_1","first-page":"421","article-title":"Battery longevity from cardiac resynchronization therapy defibrillators: Differences between manufacturers and discrepancies with published product performance reports","volume":"19","author":"Alam MB","year":"2017","journal-title":"Europace"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eut301"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euv109"},{"key":"e_1_2_8_15_1","first-page":"313","volume-title":"Clinical Cardiac Pacing, Defibrillation, and Resynchronization Therapy","author":"Lau EW","year":"2016"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/pace.12989"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1177\/002072099803500308"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1007\/s40258-017-0354-6"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/pace.12831"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euv296"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2014.07.038"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jccase.2017.02.007"},{"key":"e_1_2_8_23_1","first-page":"976","article-title":"Long\u2010term benefit of first\u2010line peri\u2010implantable cardioverter\u2010defibrillator implant ventricular tachycardia\u2010substrate ablation in secondary prevention patients","volume":"19","author":"Acosta J","year":"2017","journal-title":"Europace"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-018-0376-5"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2013.12.014"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1513614"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fpace.13642","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/pace.13642","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/pace.13642","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/pace.13642","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,10]],"date-time":"2023-09-10T18:46:57Z","timestamp":1694371617000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/pace.13642"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3,5]]},"references-count":25,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019,4]]}},"alternative-id":["10.1111\/pace.13642"],"URL":"https:\/\/doi.org\/10.1111\/pace.13642","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3,5]]},"assertion":[{"value":"2018-11-19","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-01-28","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-03-05","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}