{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T01:49:39Z","timestamp":1747187379358,"version":"3.40.5"},"reference-count":9,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2021,2,25]],"date-time":"2021-02-25T00:00:00Z","timestamp":1614211200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2021,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Manufacturers of cardiac implantable electronic devices have incorporated automatic features to allow for remote monitoring, improve device longevity, and additional safety. Algorithms to automatically measure capture threshold and adjust output to preserve battery life are one such feature. Automatic features may occasionally result in unexpected or undesirable clinical outcomes. We report on a patient who developed ventricular tachycardia inadvertently induced by the AutoCapture. feature of an Abbott\/St. Jude Medical (SJM) pacemaker.<\/jats:p>","DOI":"10.1111\/pace.14199","type":"journal-article","created":{"date-parts":[[2021,2,16]],"date-time":"2021-02-16T09:24:58Z","timestamp":1613467498000},"page":"1130-1132","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Ventricular tachycardia induced by a backup pacing stimulus in a patient with a dual chamber pacemaker with AutoCapture"],"prefix":"10.1111","volume":"44","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6877-6118","authenticated-orcid":false,"given":"Arnold J.","family":"Greenspon","sequence":"first","affiliation":[{"name":"Division of Cardiology Thomas Jefferson University Hospital  Philadelphia Pennsylvania USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7645-6405","authenticated-orcid":false,"given":"Daniel R.","family":"Frisch","sequence":"additional","affiliation":[{"name":"Division of Cardiology Thomas Jefferson University Hospital  Philadelphia Pennsylvania USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9198-5025","authenticated-orcid":false,"given":"Reginald T.","family":"Ho","sequence":"additional","affiliation":[{"name":"Division of Cardiology Thomas Jefferson University Hospital  Philadelphia Pennsylvania USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1240-7812","authenticated-orcid":false,"given":"Behzad B.","family":"Pavri","sequence":"additional","affiliation":[{"name":"Division of Cardiology Thomas Jefferson University Hospital  Philadelphia Pennsylvania USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2021,2,25]]},"reference":[{"key":"e_1_2_4_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2011.04.033"},{"key":"e_1_2_4_3_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/sum058"},{"key":"e_1_2_4_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2000.tb00880.x"},{"key":"e_1_2_4_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(85)90569-7"},{"key":"e_1_2_4_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(73)80011-6"},{"key":"e_1_2_4_7_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.68.4.707"},{"key":"e_1_2_4_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2006.07.011"},{"key":"e_1_2_4_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2009.02342.x"},{"key":"e_1_2_4_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2008.10.022"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/pace.14199","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/pace.14199","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/pace.14199","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,24]],"date-time":"2023-08-24T12:30:49Z","timestamp":1692880249000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/pace.14199"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,25]]},"references-count":9,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2021,6]]}},"alternative-id":["10.1111\/pace.14199"],"URL":"https:\/\/doi.org\/10.1111\/pace.14199","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"type":"print","value":"0147-8389"},{"type":"electronic","value":"1540-8159"}],"subject":[],"published":{"date-parts":[[2021,2,25]]},"assertion":[{"value":"2021-01-18","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-02-14","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-02-25","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}