{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,2]],"date-time":"2026-08-02T03:44:05Z","timestamp":1785642245756,"version":"3.56.0"},"reference-count":1,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2023,1,14]],"date-time":"2023-01-14T00:00:00Z","timestamp":1673654400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2023,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Newer devices incorporate advanced algorithms to have more accurate delivery of implantable cardioverter\u2010defibrillator (ICD) therapy. Newer models of Abbott Implantable cardioverter\u2010defibrillators like Gallant and Entrant have a new ventricular fibrillation (VF) therapy assurance algorithm. This algorithm has a proven role in avoiding under\u2010detection of VF where some of the smaller electrograms are under\u2010sensed. We report a case of ventricular fibrillation therapy assurance (VFTA) algorithm malfunction in a 48\u2010year\u2010old lady having single chamber Entrant Implantable cardioverter\u2010defibrillator, where the patient received inappropriate therapies. The VFTA algorithm eventually had to be turned off.<\/jats:p>","DOI":"10.1111\/pace.14654","type":"journal-article","created":{"date-parts":[[2022,12,31]],"date-time":"2022-12-31T07:24:51Z","timestamp":1672471491000},"page":"169-171","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Inappropriate ventricular fibrillation annotation and defibrillator discharge despite the same tachycardia cycle length in ventricular tachycardia\u20101 zone in an Abbott defibrillator \u2013 What is the mechanism?"],"prefix":"10.1111","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5911-4457","authenticated-orcid":false,"given":"Debabrata","family":"Bera","sequence":"first","affiliation":[{"name":"Department of Cardiology RTIICS  Kolkata India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Siddhartha","family":"Mani","sequence":"additional","affiliation":[{"name":"Department of Cardiology RTIICS  Kolkata India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ranabrata","family":"Sen","sequence":"additional","affiliation":[{"name":"Department of Cardiology RTIICS  Kolkata India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suchit","family":"Majumder","sequence":"additional","affiliation":[{"name":"Department of Cardiology Apollo Gleneagles Hospitals  Kolkata India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1274-8633","authenticated-orcid":false,"given":"Antareep","family":"Halder","sequence":"additional","affiliation":[{"name":"Department of Cardiology RTIICS  Kolkata India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adrita","family":"Ray","sequence":"additional","affiliation":[{"name":"Department of Cardiology RTIICS  Kolkata India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2023,1,14]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hroo.2021.11.009"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/pace.14654","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/pace.14654","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/pace.14654","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,18]],"date-time":"2023-08-18T22:55:29Z","timestamp":1692399329000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/pace.14654"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,14]]},"references-count":1,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023,2]]}},"alternative-id":["10.1111\/pace.14654"],"URL":"https:\/\/doi.org\/10.1111\/pace.14654","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,14]]},"assertion":[{"value":"2022-09-22","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-12-22","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-01-14","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}