{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T05:45:07Z","timestamp":1790660707447,"version":"4.1.0"},"reference-count":22,"publisher":"Wiley","issue":"12","license":[{"start":{"date-parts":[[2018,12,4]],"date-time":"2018-12-04T00:00:00Z","timestamp":1543881600000},"content-version":"vor","delay-in-days":3,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Pediatric Anesthesia"],"published-print":{"date-parts":[[2018,12]]},"abstract":"<jats:title>Summary<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>Videolaryngoscopy has an established role in difficult airway management in adults. However, there is limited literature to support their efficacy in children. The Truview Picture\u00a0Capture Device has shown promising results for endotracheal intubation in infants in the past. <jats:styled-content style=\"fixed-case\">The CMAC<\/jats:styled-content> videolaryngoscope has launched its novel infant Miller blade, but its performance has not been assessed clinically for routine intubation in infants and neonates. We hypothesized that the <jats:styled-content style=\"fixed-case\">CMAC<\/jats:styled-content> videolaryngoscope would reduce the total time to intubation as compared to the Truview Picture\u00a0Capture Device in neonates and infants.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>After parental informed consent, 80 prospective infants posted for surgical procedures under general anesthesia were randomized to undergo intubation with either of the two. The two videolaryngoscopes were also compared in terms of time required for glottis view and intubation (primary outcome), modified Cormack and Lehane grade, first attempt and overall success rate, ease of intubation, number of attempts, and any complications.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The <jats:styled-content style=\"fixed-case\">CMAC<\/jats:styled-content> significantly reduced the time required for glottic view [8\u00a0s (5.25\u20109) vs 9\u00a0s (6.5\u201012); <jats:italic>P<\/jats:italic>\u00a0=\u00a00.02] and intubation [22\u00a0s (18\u201026) vs 26\u00a0s (21.5\u201032); <jats:italic>P<\/jats:italic>\u00a0=\u00a00.003]. The median difference (95% <jats:styled-content style=\"fixed-case\">CI<\/jats:styled-content>) for time to tracheal intubation and time to glottic view was 4\u00a0s (1\u20107) and 1 (0\u20104). It also improved the ease of intubation, the Cormack\u2010Lehane grades, and first attempt success rate. Intubation with the <jats:styled-content style=\"fixed-case\">CMAC<\/jats:styled-content> was possible in 100% cases, whereas only 92.5% of patients could be intubated with the Truview. The failed intubations with the Truview could be successfully intubated with the <jats:styled-content style=\"fixed-case\">CMAC<\/jats:styled-content>.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The <jats:styled-content style=\"fixed-case\">CMAC<\/jats:styled-content> Miller blade reduced the total time taken for tracheal intubation and intubation difficulty as compared to the Truview Picture\u00a0Capture Device and may be a better tool for intubation in infants.<\/jats:p><\/jats:sec>","DOI":"10.1111\/pan.13524","type":"journal-article","created":{"date-parts":[[2018,12,4]],"date-time":"2018-12-04T11:09:52Z","timestamp":1543921792000},"page":"1148-1153","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Comparative evaluation of C<scp>MAC<\/scp> and Truview picture capture device for endotracheal intubation in neonates and infants undergoing elective surgeries: A prospective randomized control trial"],"prefix":"10.1111","volume":"28","author":[{"given":"Anju","family":"Gupta","sequence":"first","affiliation":[{"name":"VMMC and Safdarjung Hospital New Delhi India"},{"name":"Chacha Nehru Bal Chikitsalya New Delhi India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Geeta","family":"Kamal","sequence":"additional","affiliation":[{"name":"Chacha Nehru Bal Chikitsalya New Delhi India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aikta","family":"Gupta","sequence":"additional","affiliation":[{"name":"Chacha Nehru Bal Chikitsalya New Delhi India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nidhi","family":"Sehgal","sequence":"additional","affiliation":[{"name":"Chacha Nehru Bal Chikitsalya New Delhi India"},{"name":"Baba Saheb Ambedkar Hospital New Delhi India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sapna","family":"Bhatla","sequence":"additional","affiliation":[{"name":"VMMC and Safdarjung Hospital New Delhi India"},{"name":"Chacha Nehru Bal Chikitsalya New Delhi India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rajeev","family":"Kumar","sequence":"additional","affiliation":[{"name":"Scientist (Statistician) DRBRAIRCH AIIMS New Delhi India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2018,12,4]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0889-8537(05)70058-4"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.2008.01794.x"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S2213-2600(15)00508-1"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aer058"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aev371"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.2010.02285.x"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0b013e31827773b2"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2010.06294.x"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0b013e318246ea4d"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.6061\/clinics\/2014(01)04"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/pan.13316"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aex344"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2044.2000.01270.x"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003643-201306001-00839"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/ael178"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/B978-032302233-0.50041-X"},{"key":"e_1_2_9_18_1","first-page":"CD011413","article-title":"Videolaryngoscopy versus direct laryngoscopy for tracheal intubation in children (excluding neonates)","volume":"5","author":"Abdelgadir IS","year":"2017","journal-title":"Cochrane Database Syst Rev"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.aja.2017.06.001"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aex073"},{"key":"e_1_2_9_21_1","first-page":"4196813","article-title":"Comparison of the Success of two techniques for the endotracheal intubation with C\u2010MAC Video laryngoscope miller blade in children: a prospective randomized study","volume":"2016","author":"Sinha R","year":"2016","journal-title":"Anesthesiol Res Pract"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2010.06245.x"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajem.2012.08.026"}],"container-title":["Pediatric Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fpan.13524","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/pan.13524","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T16:30:42Z","timestamp":1694795442000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/pan.13524"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12]]},"references-count":22,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2018,12]]}},"alternative-id":["10.1111\/pan.13524"],"URL":"https:\/\/doi.org\/10.1111\/pan.13524","archive":["Portico"],"relation":{},"ISSN":["1155-5645","1460-9592"],"issn-type":[{"value":"1155-5645","type":"print"},{"value":"1460-9592","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,12]]},"assertion":[{"value":"2018-10-10","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-12-04","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}