{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T07:14:16Z","timestamp":1780470856311,"version":"3.54.1"},"reference-count":22,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2015,2,11]],"date-time":"2015-02-11T00:00:00Z","timestamp":1423612800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pediatrics International"],"published-print":{"date-parts":[[2015,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>Many neonatal intensive care and maternal units still use self\u2010monitoring of blood glucose (<jats:styled-content style=\"fixed-case\">SMBG<\/jats:styled-content>) devices as a tool to aid diagnosis despite the introduction of point\u2010of\u2010care testing (<jats:styled-content style=\"fixed-case\">POCT<\/jats:styled-content>) devices, which are known to have higher accuracy. We evaluated the performance of two glucose meters, the StatStrip (<jats:styled-content style=\"fixed-case\">N<\/jats:styled-content>ova <jats:styled-content style=\"fixed-case\">B<\/jats:styled-content>iomedical), a <jats:styled-content style=\"fixed-case\">POCT<\/jats:styled-content> device, and the Medisafe Mini (<jats:styled-content style=\"fixed-case\">T<\/jats:styled-content>erumo), an <jats:styled-content style=\"fixed-case\">SMBG<\/jats:styled-content> device, to detect hypoglycemia in neonates. In addition, we evaluated the interference of hematocrit, acetaminophen and ascorbic acid.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Whole blood samples were drawn from neonates who were at risk of hypoglycemia and analyzed with the StatStrip and Medisafe Mini. The results were further confirmed with blood gas analyzers <jats:styled-content style=\"fixed-case\">ABL825<\/jats:styled-content> and <jats:styled-content style=\"fixed-case\">BM6050<\/jats:styled-content>. To evaluate the interference of hematocrit, acetaminophen and ascorbic acid, concentrated solutions of glucose and interfering substances were gravimetrically prepared and analyzed.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Among the 222 blood samples analyzed, results from the StatStrip were more closely aligned to those of the <jats:styled-content style=\"fixed-case\">ABL825<\/jats:styled-content> at all levels of glucose than the Medisafe Mini.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>StatStrip appears to be unaffected by hematocrit, ascorbic acid or acetaminophen. We recommend its use in neonates in hospital. Further studies are required to identify other interference effects.<\/jats:p><\/jats:sec>","DOI":"10.1111\/ped.12543","type":"journal-article","created":{"date-parts":[[2014,12,1]],"date-time":"2014-12-01T09:36:14Z","timestamp":1417426574000},"page":"603-607","source":"Crossref","is-referenced-by-count":12,"title":["Evaluation of two glucose meters and interference corrections for screening neonatal hypoglycemia"],"prefix":"10.1111","volume":"57","author":[{"given":"Yuka","family":"Wada","sequence":"first","affiliation":[{"name":"Division of Neonatology National Center for Child Health and Development  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomoo","family":"Nakamura","sequence":"additional","affiliation":[{"name":"Division of Neonatology National Center for Child Health and Development  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masao","family":"Kaneshige","sequence":"additional","affiliation":[{"name":"Division of Neonatology National Center for Child Health and Development  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigehiro","family":"Takahashi","sequence":"additional","affiliation":[{"name":"Division of Neonatology National Center for Child Health and Development  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideshi","family":"Fujinaga","sequence":"additional","affiliation":[{"name":"Division of Neonatology National Center for Child Health and Development  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keiko","family":"Tsukamoto","sequence":"additional","affiliation":[{"name":"Division of Neonatology National Center for Child Health and Development  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yushi","family":"Ito","sequence":"additional","affiliation":[{"name":"Division of Neonatology National Center for Child Health and Development  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haruhiko","family":"Sago","sequence":"additional","affiliation":[{"name":"Center for Maternal\u2013Fetal and Neonatal Medicine National Center for Child Health and Development  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2015,2,11]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1159\/000091948"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2007-2822"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2010-3851"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.1309\/QAW1-X5XW-BVRQ-5LKQ"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-200504000-00036"},{"key":"e_1_2_5_7_1","doi-asserted-by":"publisher","DOI":"10.1185\/030079906X148274"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1177\/193229680900300438"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.POC.0000335830.31380.3d"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.POC.0000335872.51572.bb"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.5858\/2000-124-1135-EODHLO"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2431-6-28"},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.earlhumdev.2010.05.005"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiochem.2014.01.004"},{"key":"e_1_2_5_15_1","doi-asserted-by":"publisher","DOI":"10.1515\/cclm-2012-0864"},{"key":"e_1_2_5_16_1","unstructured":"DavidB DavidE JudyHet\u2009al.POCT12\u2010A3: Point\u2010of\u2010Care Blood Glucose Testing in Acute and Chronic Care Facilities; Approved Guideline 3rd edn.Clinical and Laboratory Standards Institute Colorado 2013."},{"key":"e_1_2_5_17_1","unstructured":"International Organization for Standardization.ISO15197. In Vitro Diagnostic Test Systems: Requirements for Blood\u2010Glucose Monitoring Systems for Self\u2010testing in Managing Diabetes Mellitus.ISO Geneva 2013."},{"key":"e_1_2_5_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiochem.2004.06.003"},{"key":"e_1_2_5_19_1","doi-asserted-by":"publisher","DOI":"10.3109\/10715769509147528"},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-140-7-200404060-00010"},{"key":"e_1_2_5_21_1","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.135.3.326"},{"key":"e_1_2_5_22_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-200X.2010.03214.x"},{"key":"e_1_2_5_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiochem.2014.01.004"}],"container-title":["Pediatrics International"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fped.12543","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ped.12543","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,29]],"date-time":"2023-09-29T10:48:56Z","timestamp":1695984536000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/ped.12543"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,2,11]]},"references-count":22,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2015,8]]}},"alternative-id":["10.1111\/ped.12543"],"URL":"https:\/\/doi.org\/10.1111\/ped.12543","archive":["Portico"],"relation":{},"ISSN":["1328-8067","1442-200X"],"issn-type":[{"value":"1328-8067","type":"print"},{"value":"1442-200X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,2,11]]}}}