{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T17:04:02Z","timestamp":1789405442641,"version":"build-2803163510"},"reference-count":18,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2014,3,25]],"date-time":"2014-03-25T00:00:00Z","timestamp":1395705600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Respirology"],"published-print":{"date-parts":[[2014,5]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background and objective<\/jats:title><jats:p>Dyspnoea and exercise intolerance are common in sarcoidosis and are often poorly correlated with resting lung function. Measurement of peak exercise capacity is likely to be helpful in assessing and monitoring disease. The aim of this study was to compare the modified shuttle walk test (<jats:styled-content style=\"fixed-case\">MSWT<\/jats:styled-content>) to cardiopulmonary exercise test (<jats:styled-content style=\"fixed-case\">CPET<\/jats:styled-content>) as a measure of peak exercise capacity in sarcoidosis.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Thirty\u2010three (17 male, mean age 48 years) patients with sarcoidosis completed a standardized exponential exercise protocol cycle ergometer <jats:styled-content style=\"fixed-case\">CPET<\/jats:styled-content> and a single corridor <jats:styled-content style=\"fixed-case\">MSWT<\/jats:styled-content> in random order.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Subjects has a mean forced expiratory volume in 1 s (<jats:styled-content style=\"fixed-case\">FEV<jats:sub>1<\/jats:sub><\/jats:styled-content>) 2.4\u2009L (75.7%predicted), forced vital capacity (<jats:styled-content style=\"fixed-case\">FVC<\/jats:styled-content>) 3.43\u2009L (88.7%predicted) and diffusing capacity for carbon monoxide (DLCO) 20.3\u2009mL\/min\/mm\u2009Hg (71.4%predicted). There was a strong correlation between <jats:styled-content style=\"fixed-case\">MSWT<\/jats:styled-content> distance and peak oxygen uptake (<jats:styled-content style=\"fixed-case\"><jats:roman>VO<jats:sub>2<\/jats:sub><\/jats:roman><\/jats:styled-content>) during <jats:styled-content style=\"fixed-case\">CPET<\/jats:styled-content> (r\u2009=\u20090.87; <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.0001), and between maximum heart rate during <jats:styled-content style=\"fixed-case\">MSWT<\/jats:styled-content> and <jats:styled-content style=\"fixed-case\">CPET<\/jats:styled-content> (r\u2009=\u20090.82; <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.0001). There was a moderate correlation between <jats:styled-content style=\"fixed-case\">FEV<jats:sub>1<\/jats:sub><\/jats:styled-content>, <jats:styled-content style=\"fixed-case\">FVC<\/jats:styled-content> and <jats:styled-content style=\"fixed-case\">DLCO<\/jats:styled-content> with <jats:styled-content style=\"fixed-case\">MSWT<\/jats:styled-content> distance (r\u2009=\u20090.55, r\u2009=\u20090.61, r\u2009=\u20090.61, respectively; all <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.001) and with peak <jats:styled-content style=\"fixed-case\">VO<jats:sub>2<\/jats:sub><\/jats:styled-content> (r\u2009=\u20090.62, r\u2009=\u20090.63, r\u2009=\u20090.62, respectively; all <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.0001).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Peak <jats:styled-content style=\"fixed-case\"><jats:roman>VO<jats:sub>2<\/jats:sub><\/jats:roman><\/jats:styled-content> achieved during <jats:styled-content style=\"fixed-case\">CPET<\/jats:styled-content> strongly correlated with <jats:styled-content style=\"fixed-case\">MSWT<\/jats:styled-content> distance. <jats:styled-content style=\"fixed-case\">MSWT<\/jats:styled-content> is a measure of peak exercise capacity in sarcoidosis that does not require equipment and can be readily available in the clinic.<\/jats:p><\/jats:sec>","DOI":"10.1111\/resp.12276","type":"journal-article","created":{"date-parts":[[2014,3,26]],"date-time":"2014-03-26T02:22:34Z","timestamp":1395800554000},"page":"604-607","source":"Crossref","is-referenced-by-count":10,"title":["Comparison of the modified shuttle walk test and cardiopulmonary exercise test in sarcoidosis"],"prefix":"10.1111","volume":"19","author":[{"given":"Sally","family":"de Boer","sequence":"first","affiliation":[{"name":"Green Lane Respiratory Services Auckland City Hospital  Auckland New Zealand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Kolbe","sequence":"additional","affiliation":[{"name":"Green Lane Respiratory Services Auckland City Hospital  Auckland New Zealand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Margaret L.","family":"Wilsher","sequence":"additional","affiliation":[{"name":"Green Lane Respiratory Services Auckland City Hospital  Auckland New Zealand"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2014,3,25]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1136\/thx.2008.101691"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.200308-1073WS"},{"key":"e_1_2_7_4_1","doi-asserted-by":"crossref","first-page":"2016","DOI":"10.1183\/09031936.94.07112016","article-title":"Comparison of oxygen uptake during a conventional treadmill test and the shuttle walking test in chronic airflow limitation","volume":"7","author":"Singh SJ","year":"1994","journal-title":"Eur. Respir. J."},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1136\/thx.2005.043547"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1053\/rmed.2003.1501"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.06-2822"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.200405-578OC"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2466-10-42"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1183\/09031936.00117710"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1136\/thx.54.5.437"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.117.6.1666"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1183\/09031936.98.11061354"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1136\/thx.47.12.1019"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1249\/00005768-198205000-00012"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.64.5.313"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1152\/japplphysiol.00024.2003"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.107.2.323"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.102.3.838"}],"container-title":["Respirology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fresp.12276","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/resp.12276","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,29]],"date-time":"2023-09-29T20:44:23Z","timestamp":1696020263000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/resp.12276"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,3,25]]},"references-count":18,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2014,5]]}},"alternative-id":["10.1111\/resp.12276"],"URL":"https:\/\/doi.org\/10.1111\/resp.12276","archive":["Portico"],"relation":{},"ISSN":["1323-7799","1440-1843"],"issn-type":[{"value":"1323-7799","type":"print"},{"value":"1440-1843","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,3,25]]}}}