{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T15:46:33Z","timestamp":1771515993635,"version":"3.50.1"},"reference-count":46,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2017,2,23]],"date-time":"2017-02-23T00:00:00Z","timestamp":1487808000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Seminars in Dialysis"],"published-print":{"date-parts":[[2017,5]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>End\u2010stage renal disease is frequently accompanied by cardiac comorbidity that warrants treatment with a cardiovascular implantable electronic device (permanent pacemaker or implantable cardioverter\u2010defibrillator). In the United States, chronic hemodialysis (HD) population, cardiac implantable devices are present in up to 10.5% of patients; a venous HD catheter is utilized for blood access in 18% of prevalent patients. The concomitant presence of a venous HD catheter and cardiovascular implantable device creates a high\u2010risk circumstance, with potential for causing symptomatic central venous stenosis, and for developing complicated endovascular infection. This dangerous combination may be avoided for many patients by utilizing nondialysis methods for management of advanced chronic kidney disease, initiating dialysis without venous catheter access, or managing cardiac rhythm disorders without use of transvenous cardiac implantable electronic devices. In those situations where the combination of a venous HD catheter and cardiac implantable device is unavoidable, there are strategies to minimize duration of venous catheter access, and to reduce risks for infectious complications. It is essential for nephrologists and cardiologists to understand the indications, alternatives, and risks involved with venous HD access and cardiac implantable devices. Coordinated management of renal disease and cardiac rhythm disorders has potential to minimize risks, improve outcomes, and substantially reduce the cost of care.<\/jats:p>","DOI":"10.1111\/sdi.12581","type":"journal-article","created":{"date-parts":[[2017,2,23]],"date-time":"2017-02-23T05:42:51Z","timestamp":1487828571000},"page":"187-192","source":"Crossref","is-referenced-by-count":11,"title":["Venous Hemodialysis Catheters and Cardiac Implantable Electronic Devices: Avoiding a High\u2010Risk Combination"],"prefix":"10.1111","volume":"30","author":[{"given":"Theodore F.","family":"Saad","sequence":"first","affiliation":[{"name":"Section of Renal and Hypertensive Diseases Christiana Care Health System Newark Delaware"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Henry L.","family":"Weiner","sequence":"additional","affiliation":[{"name":"Section of Cardiology Christiana Care Health System Newark Delaware"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2017,2,23]]},"reference":[{"key":"e_1_2_13_2_1","volume-title":"2016 USRDS Annual Data Report: Epidemiology of Kidney Disease in the United States","author":"United States Renal Data System","year":"2016"},{"key":"e_1_2_13_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-139X.2012.01053.x"},{"key":"e_1_2_13_4_1","doi-asserted-by":"publisher","DOI":"10.5301\/jva.5000622"},{"key":"e_1_2_13_5_1","doi-asserted-by":"publisher","DOI":"10.5527\/wjn.v5.i6.489"},{"key":"e_1_2_13_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajkd.2003.07.004"},{"key":"e_1_2_13_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2015.08.003"},{"key":"e_1_2_13_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/sdi.12249"},{"key":"e_1_2_13_9_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2011.05.005"},{"key":"e_1_2_13_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2008.02.033"},{"key":"e_1_2_13_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hfc.2016.07.010"},{"key":"e_1_2_13_12_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199711273372202"},{"key":"e_1_2_13_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0085-2538(15)50904-6"},{"key":"e_1_2_13_14_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.292.23.2874"},{"key":"e_1_2_13_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2006.00526.x"},{"key":"e_1_2_13_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2007.00651.x"},{"key":"e_1_2_13_17_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.114.001455"},{"key":"e_1_2_13_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2012.02.036"},{"key":"e_1_2_13_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2009.08.006"},{"key":"e_1_2_13_20_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2007.02.272"},{"key":"e_1_2_13_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-139X.2009.00636.x"},{"key":"e_1_2_13_22_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-139X.2012.01103.x"},{"key":"e_1_2_13_23_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1525-139x.2001.00110.x"},{"key":"e_1_2_13_24_1","doi-asserted-by":"publisher","DOI":"10.2215\/CJN.04700514"},{"key":"e_1_2_13_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2009.02569.x"},{"key":"e_1_2_13_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2009.05.020"},{"key":"e_1_2_13_27_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2002.t01-1-00804.x"},{"key":"e_1_2_13_28_1","doi-asserted-by":"publisher","DOI":"10.1001\/archinternmed.2011.441"},{"key":"e_1_2_13_29_1","unstructured":"FistulaFirst Catheter Last: Available at:http:\/\/www.fistulafirst.org\/ffcl accessed January 31 2017"},{"key":"e_1_2_13_30_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1000552"},{"key":"e_1_2_13_31_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2007.02.278"},{"key":"e_1_2_13_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2015.03.020"},{"key":"e_1_2_13_33_1","doi-asserted-by":"publisher","DOI":"10.1177\/112972980901000312"},{"key":"e_1_2_13_34_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2013.09.018"},{"key":"e_1_2_13_35_1","doi-asserted-by":"publisher","DOI":"10.2310\/6670.2010.00054"},{"key":"e_1_2_13_36_1","doi-asserted-by":"publisher","DOI":"10.5301\/jva.5000489"},{"key":"e_1_2_13_37_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-139X.2010.00757.x"},{"key":"e_1_2_13_38_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1507192"},{"key":"e_1_2_13_39_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1511643"},{"key":"e_1_2_13_40_1","first-page":"1825","article-title":"Advances in pacing therapy: examining the potential impact of leadless pacing therapy","volume":"5","author":"Higgins SL","year":"2014","journal-title":"J Innov Cardiac Rhythm Manage"},{"key":"e_1_2_13_41_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2010.04.016"},{"key":"e_1_2_13_42_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIR.0000000000000394"},{"key":"e_1_2_13_43_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa0909545"},{"key":"e_1_2_13_44_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-011-9570-4"},{"key":"e_1_2_13_45_1","doi-asserted-by":"publisher","DOI":"10.2147\/IJNRD.S76826"},{"key":"e_1_2_13_46_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2010.10.009"},{"key":"e_1_2_13_47_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-008-1204-7"}],"container-title":["Seminars in Dialysis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fsdi.12581","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/sdi.12581","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T21:04:08Z","timestamp":1696194248000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/sdi.12581"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,2,23]]},"references-count":46,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017,5]]}},"alternative-id":["10.1111\/sdi.12581"],"URL":"https:\/\/doi.org\/10.1111\/sdi.12581","archive":["Portico"],"relation":{},"ISSN":["0894-0959","1525-139X"],"issn-type":[{"value":"0894-0959","type":"print"},{"value":"1525-139X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,2,23]]}}}