{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T12:08:47Z","timestamp":1784981327791,"version":"3.55.0"},"reference-count":16,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2019,11,11]],"date-time":"2019-11-11T00:00:00Z","timestamp":1573430400000},"content-version":"vor","delay-in-days":10,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Seminars in Dialysis"],"published-print":{"date-parts":[[2019,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Tunneled dialysis catheters (TDCs) remain the predominant vascular access for initiation of hemodialysis (HD) worldwide. TDCs are also utilized in a significant number of prevalent patients for continuation of dialysis and during the periods of complications related to arteriovenous (AV) accesses. TDC placement is a routine procedure, but can be associated with mechanical and infectious complications related to placement. Imaging guidance with ultrasound and fluoroscopy has made the placement of TDC safer and more successful. Adequate operator training, careful technique, utilization of a checklist, and barrier precautions are essential to avoid problems related to TDC placement.<\/jats:p>","DOI":"10.1111\/sdi.12845","type":"journal-article","created":{"date-parts":[[2019,11,11]],"date-time":"2019-11-11T10:27:00Z","timestamp":1573468020000},"page":"535-540","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Avoiding problems in tunneled dialysis catheter placement"],"prefix":"10.1111","volume":"32","author":[{"given":"Anil K.","family":"Agarwal","sequence":"first","affiliation":[{"name":"Division of Nephrology Department of Medicine The Ohio State University Wexner Medical Center Columbus OH USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nabil","family":"Haddad","sequence":"additional","affiliation":[{"name":"Division of Nephrology Department of Medicine The Ohio State University Wexner Medical Center Columbus OH USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Khaled","family":"Boubes","sequence":"additional","affiliation":[{"name":"Division of Nephrology Department of Medicine The Ohio State University Wexner Medical Center Columbus OH USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2019,11,11]]},"reference":[{"key":"e_1_2_4_2_1","first-page":"369","article-title":"ESRD in the United States","volume":"2","year":"2018","journal-title":"United States Renal Data System"},{"key":"e_1_2_4_3_1","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0b013e3181a57bc1"},{"key":"e_1_2_4_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2012.02.012"},{"key":"e_1_2_4_5_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.11.8151"},{"key":"e_1_2_4_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/trf.13996"},{"key":"e_1_2_4_7_1","doi-asserted-by":"publisher","DOI":"10.5301\/jva.5000586"},{"key":"e_1_2_4_8_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ajkd.2012.10.024"},{"key":"e_1_2_4_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2006.12.721"},{"key":"e_1_2_4_10_1","first-page":"CD006962","article-title":"Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization","volume":"1","author":"Brass P","year":"2015","journal-title":"Cochrane Database Syst Rev"},{"key":"e_1_2_4_11_1","doi-asserted-by":"publisher","DOI":"10.1093\/ndt\/13.1.134"},{"key":"e_1_2_4_12_1","doi-asserted-by":"publisher","DOI":"10.1038\/ki.2011.52"},{"issue":"2","key":"e_1_2_4_13_1","first-page":"15","article-title":"Precautions necessary with central venous catheters","volume":"19","author":"Food and Drug Administration Task Force","year":"1989","journal-title":"FDA Drug Bulletin"},{"issue":"1","key":"e_1_2_4_14_1","first-page":"S137","article-title":"K\/ DOQI clinical practice guidelines for vascular access","volume":"37","author":"National Kidney Foundation","year":"2001","journal-title":"Am J Kidney Dis"},{"key":"e_1_2_4_15_1","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X9402200303"},{"key":"e_1_2_4_16_1","first-page":"40","volume-title":"Handbook of Dialysis Therapy","author":"Moist L","year":"2016"},{"key":"e_1_2_4_17_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1500964"}],"container-title":["Seminars in Dialysis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fsdi.12845","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/sdi.12845","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/sdi.12845","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/sdi.12845","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,8]],"date-time":"2023-09-08T20:34:19Z","timestamp":1694205259000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/sdi.12845"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11]]},"references-count":16,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2019,11]]}},"alternative-id":["10.1111\/sdi.12845"],"URL":"https:\/\/doi.org\/10.1111\/sdi.12845","archive":["Portico"],"relation":{},"ISSN":["0894-0959","1525-139X"],"issn-type":[{"value":"0894-0959","type":"print"},{"value":"1525-139X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11]]},"assertion":[{"value":"2019-11-11","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}