{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T05:54:48Z","timestamp":1768283688161,"version":"3.49.0"},"reference-count":25,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2016,2,7]],"date-time":"2016-02-07T00:00:00Z","timestamp":1454803200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100003503","name":"Nederlandse Brandwonden Stichting","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100003503","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005039","name":"Leids Universitair Medisch Centrum","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100005039","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Skin Research and Technology"],"published-print":{"date-parts":[[2016,11]]},"abstract":"<jats:sec><jats:title>Purpose<\/jats:title><jats:p>The aim of this study was to investigate the validity and reliability of a novel three\u2010dimensional imaging technique using Artec <jats:styled-content style=\"fixed-case\">MHT<\/jats:styled-content><jats:sup>\u2122<\/jats:sup> 3D Scanner for measuring the wound surface area.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The validity was tested by measuring the surface area of 60 stickers (gold standard) on 20 volunteers. Stickers with standardized areas of 2590, 7875, and 15,540 mm<jats:sup>2<\/jats:sup> were applied on the thorax, forearm, and thigh, respectively. For the reliability test, 58 burn wounds on 48 patients were assessed twice by two different observers with the Artec <jats:styled-content style=\"fixed-case\">MHT<\/jats:styled-content><jats:sup>\u2122<\/jats:sup> 3D Scanner. Scanning, post\u2010processing, and surface area measurements were performed by two clinicians.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The results for the validity analysis showed an intraclass correlation coefficient of 0.99 and coefficient of variation of the thorax, forearm, and thigh were 1.1%, 0.9%, and 0.6%, respectively. The reliability analysis showed an intraclass correlation coefficient of 0.99, a coefficient of variation of 6.3%, and limits of agreement between measurements of two observers were calculated at 0 \u00b1 0.17 \u00d7 <jats:italic>mean surface area<\/jats:italic>.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Three\u2010dimensional imaging using the Artec <jats:styled-content style=\"fixed-case\">MHT<\/jats:styled-content><jats:sup>\u2122<\/jats:sup> 3D Scanner is a valid and reliable method for measuring the wound surface area.<\/jats:p><\/jats:sec>","DOI":"10.1111\/srt.12285","type":"journal-article","created":{"date-parts":[[2016,2,8]],"date-time":"2016-02-08T06:17:24Z","timestamp":1454912244000},"page":"443-450","source":"Crossref","is-referenced-by-count":12,"title":["Three\u2010dimensional imaging: a novel, valid, and reliable technique for measuring wound surface area"],"prefix":"10.1111","volume":"22","author":[{"given":"Z. M.","family":"Rashaan","sequence":"first","affiliation":[{"name":"Department of Surgery Leiden University Medical Center Leiden the Netherlands"},{"name":"Burn Center Beverwijk Red Cross Hospital Beverwijk the Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C. M.","family":"Stekelenburg","sequence":"additional","affiliation":[{"name":"Department of Plastic and Reconstructive Surgery VU University of Amsterdam Amsterdam the Netherlands"},{"name":"The MOVE Research Institute VU University of Amsterdam Amsterdam the Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M. B. A.","family":"van der Wal","sequence":"additional","affiliation":[{"name":"The MOVE Research Institute VU University of Amsterdam Amsterdam the Netherlands"},{"name":"Associations of Dutch Burn Centers Beverwijk the Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A. M.","family":"Euser","sequence":"additional","affiliation":[{"name":"Department of Clinical Epidemiology Leiden University Medical Center Leiden the Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B. J. M.","family":"Hagendoorn","sequence":"additional","affiliation":[{"name":"Burn Center Beverwijk Red Cross Hospital Beverwijk the Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P. P. M.","family":"van Zuijlen","sequence":"additional","affiliation":[{"name":"Burn Center Beverwijk Red Cross Hospital Beverwijk the Netherlands"},{"name":"Department of Plastic and Reconstructive Surgery VU University of Amsterdam Amsterdam the Netherlands"},{"name":"The MOVE Research Institute VU University of Amsterdam Amsterdam the Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R. S.","family":"Breederveld","sequence":"additional","affiliation":[{"name":"Department of Surgery Leiden University Medical Center Leiden the Netherlands"},{"name":"Burn Center Beverwijk Red Cross Hospital Beverwijk the Netherlands"},{"name":"Associations of Dutch Burn Centers Beverwijk the Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2016,2,7]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.12968\/jowc.2003.12.5.26493"},{"key":"e_1_2_9_3_1","first-page":"e18","article-title":"A comparison of wound area measurement techniques: visitrak versus photography","volume":"11","author":"Chang AC","year":"2011","journal-title":"Eplasty"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1017\/CBO9780511996214"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.2337\/dc07-0122"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/00129334-200209000-00011"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/00129334-200405000-00018"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1177\/1534734604263200"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2702.2007.01790.x"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.12968\/jowc.2005.14.5.26771"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.12968\/bjon.1998.7.13.5646"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.ASW.0000305411.58350.7d"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1093\/ptj\/72.2.138"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.ASW.0000284967.69863.2f"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/WON.0b013e318215fc60"},{"issue":"42","key":"e_1_2_9_16_1","first-page":"37","article-title":"Methods for assessing change in ulcer status","volume":"8","author":"Harding KG","year":"1995","journal-title":"Adv Wound Care"},{"key":"e_1_2_9_17_1","first-page":"337","article-title":"Two\u2010dimensional wound measurement: comparison of 4 techniques","volume":"11","author":"Langemo DK","year":"1998","journal-title":"Adv Wound Care"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/PRS.0b013e318290f675"},{"key":"e_1_2_9_19_1","unstructured":"Artec Group.How Artec MHT\u21223D works 2013. Available at:http:\/\/www.artec3d.com\/hardware\/artec-s\/how_it_works\/(accessed 2 November 2013)."},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinepi.2005.10.015"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinepi.2007.11.003"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1350-4533(98)00034-4"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.4103\/0970-0358.101333"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1097\/00129334-200107000-00011"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1097\/00004630-199111000-00010"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1524-475X.2007.00300.x"}],"container-title":["Skin Research and Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fsrt.12285","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/srt.12285","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,24]],"date-time":"2023-09-24T11:27:58Z","timestamp":1695554878000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/srt.12285"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,2,7]]},"references-count":25,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2016,11]]}},"alternative-id":["10.1111\/srt.12285"],"URL":"https:\/\/doi.org\/10.1111\/srt.12285","archive":["Portico"],"relation":{},"ISSN":["0909-752X","1600-0846"],"issn-type":[{"value":"0909-752X","type":"print"},{"value":"1600-0846","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,2,7]]}}}