{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T19:02:11Z","timestamp":1770231731582,"version":"3.49.0"},"reference-count":26,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2017,5,19]],"date-time":"2017-05-19T00:00:00Z","timestamp":1495152000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"Fresenius (Bad Homburg, Germany)"},{"name":"Department of Anesthesiology, University Hospital of Regensburg"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Transfusion Medicine"],"published-print":{"date-parts":[[2017,8]]},"abstract":"<jats:title>SUMMARY<\/jats:title><jats:sec><jats:title>Background and objectives<\/jats:title><jats:p>Cell salvage plays a key role in blood conservation. To maintain high performance, quality management is recommended. Accordingly, a new\u2010generation autotransfusion device was tested for its performance and compared with its predecessor. Two different calculations of quality parameters were applied.<\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and methods<\/jats:title><jats:p>In an experimental study, the continuous autotransfusion devices <jats:styled-content style=\"fixed-case\">CATSmart<\/jats:styled-content> and Continuous Autotransfusion System (C.A.T.S) plus were tested using banked blood adjusted to a haematocrit of 20% and anticoagulated with heparin 5\u2009U\/L. Test blood was processed using an emergency programme, a high\u2010quality programme\/smart wash programme and a low\u2010volume wash programme. Samples were taken after the production of <jats:styled-content style=\"fixed-case\">200\u2009mL<\/jats:styled-content> of red blood cells (<jats:styled-content style=\"fixed-case\">RBC<\/jats:styled-content>) and after the final emptying of the separation chamber. In an additional set of tests, blood containing 1\u00b725% fat was processed with both devices to examine fat removal.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Both devices demonstrated an equally high performance with regards to product hematocrit (Hct); <jats:styled-content style=\"fixed-case\">RBC<\/jats:styled-content> recovery; and elimination rates of protein, heparin and fat. The high fat elimination rate (&gt;99\u00b78%) reported for C.A.T.S plus was confirmed for <jats:styled-content style=\"fixed-case\">CATSmart<\/jats:styled-content>, regardless of the used programme. Samples taken during the ongoing process show a higher haematocrit and <jats:styled-content style=\"fixed-case\">RBC<\/jats:styled-content> recovery rate than samples taken after the final emptying of the separation chamber. Interface sensors were not affected by fat in the blood.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The new\u2010generation autotransfusion device <jats:styled-content style=\"fixed-case\">CATSmart<\/jats:styled-content> is not inferior to its predecessor and shows high performance with regards to <jats:styled-content style=\"fixed-case\">RBC<\/jats:styled-content> recovery, plasma and fat  elimination in all programme modes. Samples for quality controls should be taken during blood processing.<\/jats:p><\/jats:sec>","DOI":"10.1111\/tme.12421","type":"journal-article","created":{"date-parts":[[2017,5,19]],"date-time":"2017-05-19T10:49:28Z","timestamp":1495190968000},"page":"292-299","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Performance of a new\u2010generation continuous autotransfusion device including fat removal and consequences for quality controls"],"prefix":"10.1111","volume":"27","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6380-8520","authenticated-orcid":false,"given":"T. F.","family":"Seyfried","sequence":"first","affiliation":[{"name":"Department of Anesthesiology University Hospital Regensburg  Regensburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Gruber","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology University Hospital Regensburg  Regensburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"Bitzinger","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology University Hospital Regensburg  Regensburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M. T.","family":"Pawlik","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology University Hospital Regensburg  Regensburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Breu","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology University Hospital Regensburg  Regensburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B. M.","family":"Graf","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology University Hospital Regensburg  Regensburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E.","family":"Hansen","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology University Hospital Regensburg  Regensburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2017,5,19]]},"reference":[{"key":"e_1_2_8_2_1","volume-title":"Standards for Perioperative Autologous Blood Collection and Administration","author":"AABB","year":"2015"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12871-016-0204-3"},{"key":"e_1_2_8_4_1","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1213\/00000539-199711000-00002","article-title":"Fat  elimination during intraoperative  autotransfusion: an in vitro investigation","volume":"85","author":"Booke M.","year":"1997","journal-title":"Anesthesia and Analgesia"},{"key":"e_1_2_8_5_1","first-page":"307","article-title":"Intraoperative autotransfusion\u2010influence of technique, speed, and  hematocrit on quality","volume":"27","author":"Booke M.","year":"2000","journal-title":"Infusion Therapy and Transfusion Medicine"},{"key":"e_1_2_8_6_1","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1213\/00000539-200102000-00011","article-title":"Fat  elimination from autologous blood","volume":"92","author":"Booke M.","year":"2001","journal-title":"Anesthesia and Analgesia"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-3148.2002.00369.x"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.jvca.2004.01.001"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1191\/0267659103pf630oa"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1191\/0267659104pf713oa"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1191\/0267659103pf644oa"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1177\/039139889601900709"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.2012.03853.x"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1159\/000064232"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1159\/000080405"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1010-7940(02)00834-5"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2011.06862.x"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(00)01588-5"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1177\/0267659107080826"},{"key":"e_1_2_8_20_1","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1051\/ject\/200335128","article-title":"Quality of red blood cells using autotransfusion devices: a comparative analysis","volume":"35","author":"Serrick C.J.","year":"2003","journal-title":"The Journal of Extra\u2010Corporeal Technology"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/trf.12765"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1111\/trf.13035"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1111\/trf.13286"},{"key":"e_1_2_8_24_1","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1051\/ject\/2000322011","article-title":"Quality of processed blood for autotransfusion","volume":"32","author":"Shulman G.","year":"2000","journal-title":"The Journal of Extra\u2010Corporeal Technology"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0116835"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAT.0b013e31827b5187"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10047-013-0745-x"}],"container-title":["Transfusion Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Ftme.12421","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/tme.12421","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T19:19:06Z","timestamp":1696187946000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/tme.12421"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,5,19]]},"references-count":26,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2017,8]]}},"alternative-id":["10.1111\/tme.12421"],"URL":"https:\/\/doi.org\/10.1111\/tme.12421","archive":["Portico"],"relation":{},"ISSN":["0958-7578","1365-3148"],"issn-type":[{"value":"0958-7578","type":"print"},{"value":"1365-3148","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,5,19]]},"assertion":[{"value":"2016-09-16","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2017-04-17","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2017-05-19","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}