{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T11:56:59Z","timestamp":1788782219288,"version":"build-2803163510"},"reference-count":42,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2016,1,12]],"date-time":"2016-01-12T00:00:00Z","timestamp":1452556800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"TOSOH Bioscience Ltd"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Veterinary Clinical Pathol"],"published-print":{"date-parts":[[2016,3]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>\n                      Equine pituitary pars intermedia dysfunction (\n                      <jats:styled-content style=\"fixed-case\">PPID<\/jats:styled-content>\n                      ) may be diagnosed by measuring baseline plasma adrenocorticotrophic hormone (\n                      <jats:styled-content style=\"fixed-case\">ACTH<\/jats:styled-content>\n                      ). The Immulite 1000 analyzer uses an automated chemiluminescence enzyme assay, previously validated for measuring equine\n                      <jats:styled-content style=\"fixed-case\">ACTH<\/jats:styled-content>\n                      . Recently, an automated bench\u2010top immunoassay analyzer (\n                      <jats:styled-content style=\"fixed-case\">AIA<\/jats:styled-content>\n                      \u2010360), designed for analytes in people, became available for veterinary use.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>\n                      Objectives were to evaluate analytic performance of the\n                      <jats:styled-content style=\"fixed-case\">AIA<\/jats:styled-content>\n                      immunoassay for measuring equine\n                      <jats:styled-content style=\"fixed-case\">ACTH<\/jats:styled-content>\n                      , and compare the results with those obtained by the Immulite.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Adrenocorticotrophic hormone was measured in plasma samples from 52 clinical cases. For the\n                      <jats:styled-content style=\"fixed-case\">AIA<\/jats:styled-content>\n                      , within\u2010 and between\u2010run coefficients of variation (\n                      <jats:styled-content style=\"fixed-case\">CV<\/jats:styled-content>\n                      ) were assessed, linearity and recovery studies performed, and observed total error (\n                      <jats:styled-content style=\"fixed-case\">TE<\/jats:styled-content>\n                      <jats:sub>obs<\/jats:sub>\n                      ) calculated. Correlation and agreement between the 2 analyzers were also evaluated.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Within\u2010run and between\u2010run\n                      <jats:styled-content style=\"fixed-case\">CV<\/jats:styled-content>\n                      of the\n                      <jats:styled-content style=\"fixed-case\">AIA<\/jats:styled-content>\n                      ranged from 2.3% to 4% and 3.5% to 8%, respectively.\n                      <jats:styled-content style=\"fixed-case\">ACTH<\/jats:styled-content>\n                      recoveries ranged from 89.5% to 115.9%.\n                      <jats:styled-content style=\"fixed-case\">TE<\/jats:styled-content>\n                      <jats:sub>obs<\/jats:sub>\n                      at 26.5 pg\/mL\n                      <jats:styled-content style=\"fixed-case\">ACTH<\/jats:styled-content>\n                      was 4.1 pg\/mL. The\n                      <jats:styled-content style=\"fixed-case\">ACTH<\/jats:styled-content>\n                      results (median: 25.9 pg\/mL; range: 4.3\u2013276.7 pg\/mL) with\n                      <jats:styled-content style=\"fixed-case\">AIA<\/jats:styled-content>\n                      were significantly lower (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .0001) than with the Immulite (median: 29.9 pg\/mL; range: 10.3\u2013639.0 pg\/mL). Correlation between the 2 analyzers was\n                      <jats:italic>r<\/jats:italic>\n                      = 0.882 (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; .0001), with a significant bias for the\n                      <jats:styled-content style=\"fixed-case\">AIA<\/jats:styled-content>\n                      of \u221216 pg\/mL. The 2 methods were not identical within inherent imprecision.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>\n                      The\n                      <jats:styled-content style=\"fixed-case\">AIA<\/jats:styled-content>\n                      is precise for measuring\n                      <jats:styled-content style=\"fixed-case\">ACTH<\/jats:styled-content>\n                      in horses. Although correlation between the instruments is good, the values obtained by the immunoassays cannot be used interchangeably and should be interpreted using reference intervals established for each analyzer to avoid false negatives. Diagnostic sensitivity and specificity of the\n                      <jats:styled-content style=\"fixed-case\">AIA<\/jats:styled-content>\n                      \u2010360 should be evaluated before clinical use.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/vcp.12326","type":"journal-article","created":{"date-parts":[[2016,1,12]],"date-time":"2016-01-12T10:22:27Z","timestamp":1452594147000},"page":"154-163","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":27,"title":["Initial analytic quality assessment and method comparison of an immunoassay for adrenocorticotropic hormone measurement in equine samples"],"prefix":"10.1111","volume":"45","author":[{"given":"Katherine L.","family":"Irvine","sequence":"first","affiliation":[{"name":"School of Veterinary Sciences University of Bristol Langford Bristol UK"},{"name":"Diagnostic Laboratories Langford Veterinary Services University of Bristol Bristol UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kay","family":"Burt","sequence":"additional","affiliation":[{"name":"School of Veterinary Sciences University of Bristol Langford Bristol UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew J.","family":"Hill","sequence":"additional","affiliation":[{"name":"Equine Centre Langford Veterinary Services University of Bristol Bristol UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephanie","family":"Shaw","sequence":"additional","affiliation":[{"name":"TOSOH Bioscience Ltd The Business Centre Redditch UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kostas","family":"Papasouliotis","sequence":"additional","affiliation":[{"name":"School of Veterinary Sciences University of Bristol Langford Bristol UK"},{"name":"Diagnostic Laboratories Langford Veterinary Services University of Bristol Bristol UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2016,1,12]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.2460\/javma.2000.217.1195"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-165X.2007.tb00202.x"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1439-0442.1994.tb00061.x"},{"key":"e_1_2_6_5_1","first-page":"381","article-title":"Evaluation of the dry chemical analysis system VetTest 8008","volume":"137","author":"Tschudi PR","year":"1995","journal-title":"Schweiz Arch Tierheilkd"},{"key":"e_1_2_6_6_1","first-page":"231","article-title":"Use of the dry chemistry \u201cReflotron\u201d blood analyzer under outdoor\u2010field conditions in veterinary medicine","volume":"34","author":"Lopes\u2010Pereira CM","year":"1996","journal-title":"Eur J Clin Chem Clin Biochem"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.5402\/2012\/475419"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.2460\/javma.2003.223.93"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-0739(02)00018-4"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2826.2005.01277.x"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1210\/endo-123-3-1598"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1354\/vp.45-1-26"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-1676.2012.00932.x"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/0739-7240(94)00006-M"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-1676.1996.tb02016.x"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.2746\/042516402776250333"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tvjl.2010.04.014"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.2042-3306.2011.00444.x"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jevs.2008.04.007"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/evj.12114"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/jsap.12181"},{"key":"e_1_2_6_22_1","unstructured":"LabCorp: Adrenocorticotropic Hormone (ACTH) Plasma. LabCorp ed. 2014. Available at:https:\/\/www.labcorp.com\/wps\/portal\/!ut\/p\/c1\/04_SB8K8xLLM9MSSzPy8xBz9CP0os_hACzO_QCM_IwMLXyM3AyNjMycDU2dXQwN3M6B8JG55AwMCuv088nNT9QtyI8oBPK_DWA!!\/dl2\/d1\/L0lDU0NTQ1FvS1VRIS9JSFJBQUlnb0FNeUtibTZtL1lCSkp3NDU0a3N1eWx3ISEvN19VRTRTMUk5MzBPR1MyMElTM080TjJONjY4MC9zZWFyY2hCeUtleXdvcmQ!\/?criterion=004440. Accessed September 13 2014."},{"key":"e_1_2_6_23_1","volume-title":"IMMULITE\u00ae\/IMMULITE\u00ae 1000 ACTH","author":"Siemens","year":"2006"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1210\/endo-110-4-1430"},{"key":"e_1_2_6_25_1","volume-title":"Immulite\u20101000 Immunoassay System, Operator's Manual, Document Number 600884\u20100002, Revision A, version 5.XX","author":"Siemens","year":"2009"},{"key":"e_1_2_6_26_1","volume-title":"ST AIA\u2010PACK ACTH","author":"TOSOH","year":"2010"},{"key":"e_1_2_6_27_1","volume-title":"Automated Enzyme Immunoassay Analyser, Operator's Manual, Rev: 2013\u201006\u2010030","author":"TOSOH","year":"2013"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-165X.2003.tb00333.x"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-165X.2009.00135.x"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-165X.2010.00251.x"},{"key":"e_1_2_6_31_1","volume-title":"Basic Method Validation","author":"Westgard JO","year":"2008"},{"key":"e_1_2_6_32_1","doi-asserted-by":"publisher","DOI":"10.1111\/vcp.12101"},{"key":"e_1_2_6_33_1","doi-asserted-by":"publisher","DOI":"10.1111\/vcp.12122"},{"key":"e_1_2_6_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"e_1_2_6_35_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-165X.2006.tb00131.x"},{"key":"e_1_2_6_36_1","doi-asserted-by":"publisher","DOI":"10.1177\/104063870501700207"},{"key":"e_1_2_6_37_1","doi-asserted-by":"publisher","DOI":"10.1177\/1040638712455171"},{"key":"e_1_2_6_38_1","volume-title":"The Immunoassay Handbook","author":"Wild D","year":"2013"},{"key":"e_1_2_6_39_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-1676.2002.tb02418.x"},{"key":"e_1_2_6_40_1","unstructured":"RCPA: Quality Assurance Program \u2010 Allowable Limits of Performance. RCPA ed. 2014. Available at:http:\/\/www.rcpaqap.com.au\/wp-content\/uploads\/2014\/11\/chempath\/docs\/Allowable_Limits_of_Performance.pdf. Accessed June 30 2014."},{"key":"e_1_2_6_41_1","doi-asserted-by":"publisher","DOI":"10.1210\/endo-110-3-941"},{"issue":"1","key":"e_1_2_6_42_1","first-page":"S11","article-title":"Pre\u2010analytical requirements","volume":"29","author":"Livesey JH","year":"2008","journal-title":"Clin Biochem Rev"},{"key":"e_1_2_6_43_1","doi-asserted-by":"publisher","DOI":"10.1373\/clinchem.2006.080622"}],"container-title":["Veterinary Clinical Pathology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fvcp.12326","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vcp.12326","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,17]],"date-time":"2023-09-17T04:05:34Z","timestamp":1694923534000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/vcp.12326"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,1,12]]},"references-count":42,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2016,3]]}},"alternative-id":["10.1111\/vcp.12326"],"URL":"https:\/\/doi.org\/10.1111\/vcp.12326","archive":["Portico"],"relation":{},"ISSN":["0275-6382","1939-165X"],"issn-type":[{"value":"0275-6382","type":"print"},{"value":"1939-165X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,1,12]]},"assertion":[{"value":"2016-01-12","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}