{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T20:46:39Z","timestamp":1788900399526,"version":"build-2803163510"},"reference-count":26,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2020,6,10]],"date-time":"2020-06-10T00:00:00Z","timestamp":1591747200000},"content-version":"vor","delay-in-days":9,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100004508","name":"Prince of Songkla University","doi-asserted-by":"publisher","award":["MET610569S"],"award-info":[{"award-number":["MET610569S"]}],"id":[{"id":"10.13039\/501100004508","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Veterinary Clinical Pathol"],"published-print":{"date-parts":[[2020,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>The Mindray BC\u20105000Vet hematology analyzer is a flow cytometry\u2010based automated hematology analyzer that generates a complete blood count with a five\u2010part white blood cell (WBC) differential count.<\/jats:p><\/jats:sec><jats:sec><jats:title>Objectives<\/jats:title><jats:p>We aimed to validate reliability results of the Mindray BC\u20105000Vet for use in dog and cat blood.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Imprecision was performed using the manufacturer\u2019s quality control material at low, normal, and high levels. Blood sample results of healthy and ill dogs and cats were studied for comparability between manual methods and the Mindray BC\u20105000Vet analyzer. Forty dogs and 40 cats were included in the study.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Precision for red blood cell (RBC) parameters was excellent, with a coefficient of variation within\u2010run (%CV<jats:sub>w<\/jats:sub>) and between\u2010run (%CV<jats:sub>b<\/jats:sub>) of &lt;2%. WBC count and differential count showed %CV<jats:sub>w<\/jats:sub> and %CV<jats:sub>b<\/jats:sub> &lt;8%; however, %CV<jats:sub>w<\/jats:sub> and %CV<jats:sub>b<\/jats:sub> of low\u2010level control material gave &gt;9% eosinophils. The correlation between the BC\u20105000 Vet and manual methods in normal and abnormal canine and feline blood samples showed excellent correlations for the RBC counts, hemoglobin concentrations, hematocrits, and WBC counts (<jats:italic>r<\/jats:italic>\u00a0&gt;\u00a0.93). The differential WBC analysis of canine blood showed good correlation (<jats:italic>r<\/jats:italic>\u00a0=\u00a0.80\u2010.92). Feline blood samples showed excellent correlations for neutrophils and lymphocytes, with a good correlation for\u00a0monocytes and eosinophils.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The Mindray BC\u20105000Vet hematology analyzer proved a suitable instrument for routine analysis in dogs and cats with various hematologic abnormalities.<\/jats:p><\/jats:sec>","DOI":"10.1111\/vcp.12861","type":"journal-article","created":{"date-parts":[[2020,6,11]],"date-time":"2020-06-11T05:24:39Z","timestamp":1591853079000},"page":"207-216","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Precision and accuracy of the Mindray BC\u20105000Vet hematology analyzer for canine and feline blood"],"prefix":"10.1111","volume":"49","author":[{"given":"Sorawat","family":"Thongsahuan","sequence":"first","affiliation":[{"name":"Faculty of Veterinary Science Prince of Songkla University Hat Yai Songkhla Thailand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lalita","family":"Fonghoi","sequence":"additional","affiliation":[{"name":"Faculty of Medical Technology Prince of Songkla University Hat Yai Songkhla Thailand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sunita","family":"Kaewfai","sequence":"additional","affiliation":[{"name":"Faculty of Medical Technology Prince of Songkla University Hat Yai Songkhla Thailand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1806-2544","authenticated-orcid":false,"given":"Kanitta","family":"Srinoun","sequence":"additional","affiliation":[{"name":"Faculty of Medical Technology Prince of Songkla University Hat Yai Songkhla Thailand"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2020,6,10]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1177\/1040638711425572"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1177\/1040638711436243"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-165X.2009.00125.x"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-165X.2009.00126.x"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-165X.2004.tb00347.x"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1186\/1746-6148-10-125"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-165X.1997.tb00726.x"},{"key":"e_1_2_8_9_1","volume-title":"Procedures and Devices for the Collection of Diagnostic Capillary Blood Specimens","author":"Clinical and Laboratory Standards Institute (CLSI).","year":"2008"},{"key":"e_1_2_8_10_1","unstructured":"Mindray Bio\u2010Medical Electronics Co. Ltd.Operator\u2019s Manual: BC\u20105000 Vet Auto Hematology Analyzer.Shenzhen China:Mindray Bio\u2010Medical Electronics Co Ltd;2013."},{"key":"e_1_2_8_11_1","volume-title":"Evaluation of Precision Performance of Clinical Chemistry Devices","author":"Clinical and Laboratory Standards Institute (CLSI)","year":"2004"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/ijlh.12201"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/vcp.12583"},{"key":"e_1_2_8_14_1","volume-title":"Hematology Clinical Principle & Application","author":"Hippel TG","year":"2007"},{"key":"e_1_2_8_15_1","first-page":"17","volume-title":"Veterinary Technician's Handbook of Laboratory Procedures","author":"Bellwood B","year":"2013"},{"key":"e_1_2_8_16_1","first-page":"3","volume-title":"Veterinary hematology and clinical chemistry","author":"Thrall MA","year":"2012"},{"key":"e_1_2_8_17_1","first-page":"17","volume-title":"Veterinary Technician\u2019s Handbook of Laboratory Procedures","author":"Bellwood B","year":"2014"},{"key":"e_1_2_8_18_1","volume-title":"Reference Leukocyte (WBC) Differential Count (Proportional) and Evaluation of Instrumental Methods","author":"Clinical and Laboratory Standards Institute (CLSI)","year":"2007"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-165X.2006.tb00131.x"},{"key":"e_1_2_8_20_1","first-page":"7002","article-title":"Proficiency testing criteria for acceptable analytical performance","volume":"57","author":"Clinical Laboratory Improvement Amendments (CLIA)","year":"1992","journal-title":"Fed Reg"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-165X.2006.tb00134.x"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-165X.2012.00405.x"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02752849"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-165X.1999.tb01055.x"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-165X.1995.tb00938.x"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-165X.1996.tb00960.x"},{"issue":"4","key":"e_1_2_8_27_1","first-page":"324","article-title":"Calibration of hematology analyzers. Role of the microhematocrit","volume":"111","author":"Crawford JM","year":"1987","journal-title":"Arch Pathol Lab Med"}],"container-title":["Veterinary Clinical Pathology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vcp.12861","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/vcp.12861","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vcp.12861","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,3]],"date-time":"2023-09-03T08:05:48Z","timestamp":1693728348000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/vcp.12861"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6]]},"references-count":26,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,6]]}},"alternative-id":["10.1111\/vcp.12861"],"URL":"https:\/\/doi.org\/10.1111\/vcp.12861","archive":["Portico"],"relation":{},"ISSN":["0275-6382","1939-165X"],"issn-type":[{"value":"0275-6382","type":"print"},{"value":"1939-165X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6]]},"assertion":[{"value":"2019-03-30","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-10-31","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-06-10","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}