{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T10:16:32Z","timestamp":1791281792184,"version":"4.1.0"},"reference-count":24,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2013,7,15]],"date-time":"2013-07-15T00:00:00Z","timestamp":1373846400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Vet Emergen Crit Care"],"published-print":{"date-parts":[[2013,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Objective<\/jats:title><jats:p>To determine the agreement between blood pressure obtained with a noninvasive technique and direct technique using the Surgivet V9203 at varying blood pressure levels created using a canine hemorrhage model.<\/jats:p><\/jats:sec><jats:sec><jats:title>Design<\/jats:title><jats:p>Experimental study.<\/jats:p><\/jats:sec><jats:sec><jats:title>Setting<\/jats:title><jats:p>University Teaching Hospital.<\/jats:p><\/jats:sec><jats:sec><jats:title>Animals<\/jats:title><jats:p>Twenty\u2010nine greyhounds with an average weight of 30 kg. Approval from the Murdoch University Animal Ethics Committee was obtained (R228609).<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Arterial blood pressure (BP) was measured noninvasively (NIBP) via a cuff placed over the dorsal metatarsal artery and via a catheter in the contralateral dorsal metatarsal artery (IBP). Retrospectively the blood pressure measurements recorded were divided into various BP categories. A total of 84 paired readings were obtained. The data were further analyzed with respect to heart rate [&lt;120\/min and &gt;120\/min]. Comparison of the measurements was performed using the Bland\u2013Altman method.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>For all categories, BP measurements were generally lower when recorded using the oscillometric technique [Systolic (Sys) bias 4.20 kPa (31.54 mm Hg), mean bias 0.52 kPa (3.93 mm Hg), and diastolic bias 1.04 kPa (7.83 mm Hg)]. Mean arterial BP had the least bias and greatest precision in the hypotensive group (bias 0.174 kPa (1.3063 mm Hg), precision 0.79 kPa (5.89 mm Hg)), low BP group (bias 0.62 kPa (4.67mm Hg) and precision 0.89 kPa (6.67mm Hg)) and normotensive group [bias 0.76 kPa (5.71 mm Hg) and precision 1.16 kPa (8.73 mmHg)].<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The results demonstrate that the agreement between NIBP measurements and IBP, are within the limits of agreement recommended by the American College of Veterinary Internal Medicine Hypertension Consensus Panel for all pressures except Sys BP. This suggests that mean and diastolic NIBP using the Surgivet V9203 are a clinically acceptable alternative of IBP in hypovolemic hypotensive dogs.<\/jats:p><\/jats:sec>","DOI":"10.1111\/vec.12075","type":"journal-article","created":{"date-parts":[[2013,7,15]],"date-time":"2013-07-15T15:28:56Z","timestamp":1373902136000},"page":"523-531","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Comparison of invasive versus noninvasive blood pressure measurements before and after hemorrhage in anesthetized greyhounds using the<scp>S<\/scp>urgivet<scp>V<\/scp>9203"],"prefix":"10.1111","volume":"23","author":[{"given":"Eleanor A.","family":"Drynan","sequence":"first","affiliation":[{"name":"Department of Anaesthesia, School of Veterinary and Biomedical Sciences Murdoch University Murdoch Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthea L.","family":"Raisis","sequence":"additional","affiliation":[{"name":"Department of Anaesthesia, School of Veterinary and Biomedical Sciences Murdoch University Murdoch Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2013,7,15]]},"reference":[{"issue":"4","key":"e_1_2_8_2_1","first-page":"122","article-title":"Blood pressure measurement","volume":"7","author":"Ward M","year":"2007","journal-title":"CEACCP"},{"key":"e_1_2_8_3_1","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1177\/0310057X9302100508","article-title":"The Australian incident monitoring study. Which monitor? An analysis of 2000 incident reports","volume":"21","author":"Webb R","year":"1993","journal-title":"Anaesth Intensive Care"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(98)00355-5"},{"key":"e_1_2_8_5_1","volume-title":"Pharmacology and Physiology in Anaesthetic Practice","author":"Stoelting R","year":"1987"},{"issue":"9","key":"e_1_2_8_6_1","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.2460\/javma.1997.210.09.1279","article-title":"Arterial blood pressure monitoring in anaesthetised animals","volume":"210","author":"Wagner A","year":"1997","journal-title":"JAm Vet Med Assoc"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/0034-5288(94)90116-3"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1467-2995.2007.00346.x"},{"key":"e_1_2_8_9_1","first-page":"238","article-title":"Comparison of direct and indirect pressure measurements in anesthetized dogs","volume":"59","author":"Gains M","year":"1995","journal-title":"Can J Vet Res"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11259-010-9346-9"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1467-2995.2004.00141.x"},{"issue":"4","key":"e_1_2_8_12_1","first-page":"464","article-title":"Comparison of telemetry and high\u2010definition oscillometry for blood pressure measurements in conscious dogs: effects of torcetrapib","volume":"49","author":"Meyer O","year":"2010","journal-title":"J Am Assoc Lab Anim Sci"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0684.2009.00344.x"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1476-4431.2010.00536.x"},{"key":"e_1_2_8_15_1","first-page":"2521","volume-title":"Textbook of Small Animal Surgery","author":"Haskins S","year":"2003"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.5326\/15473317-35-1-13"},{"key":"e_1_2_8_17_1","first-page":"93","volume-title":"Textbook of Veterinary Internal Medicine","author":"Littman M","year":"1995"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.2307\/2987937"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.2460\/ajvr.67.9.1541"},{"key":"e_1_2_8_20_1","volume-title":"Understanding Anaesthesia Equipment","author":"Dorsch J","year":"2007"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-1676.1995.tb03301.x"},{"issue":"1","key":"e_1_2_8_22_1","first-page":"48","article-title":"Blood pressure monitoring","volume":"93","author":"Grosenbaugh D","year":"1998","journal-title":"Vet Med"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.2.3.373"},{"key":"e_1_2_8_24_1","volume-title":"McDonald's Blood Flow in Arteries","author":"Nichols W","year":"1998"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-1676.2007.tb03005.x"}],"container-title":["Journal of Veterinary Emergency and Critical Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fvec.12075","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vec.12075","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,14]],"date-time":"2024-05-14T17:35:09Z","timestamp":1715708109000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/vec.12075"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,7,15]]},"references-count":24,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2013,9]]}},"alternative-id":["10.1111\/vec.12075"],"URL":"https:\/\/doi.org\/10.1111\/vec.12075","archive":["Portico"],"relation":{},"ISSN":["1479-3261","1476-4431"],"issn-type":[{"value":"1479-3261","type":"print"},{"value":"1476-4431","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,7,15]]},"assertion":[{"value":"2011-12-10","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2013-06-03","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2013-07-15","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}