{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T15:59:57Z","timestamp":1781107197219,"version":"3.54.1"},"reference-count":13,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2016,1,15]],"date-time":"2016-01-15T00:00:00Z","timestamp":1452816000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Vet Emergen Crit Care"],"published-print":{"date-parts":[[2016,3]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Objective<\/jats:title><jats:p>To evaluate the accuracy of a commercial blood transfusion cross\u2010match kit when compared to the standard laboratory method for establishing blood transfusion compatibility.<\/jats:p><\/jats:sec><jats:sec><jats:title>Design<\/jats:title><jats:p>A prospective observational in intro study performed from July 2009 to July 2013.<\/jats:p><\/jats:sec><jats:sec><jats:title>Setting<\/jats:title><jats:p>Private referral veterinary center.<\/jats:p><\/jats:sec><jats:sec><jats:title>Animals<\/jats:title><jats:p>Ten healthy dogs, 11 anemic dogs, and 24 previously transfused dogs.<\/jats:p><\/jats:sec><jats:sec><jats:title>Interventions<\/jats:title><jats:p>None.<\/jats:p><\/jats:sec><jats:sec><jats:title>Measurement and Main Results<\/jats:title><jats:p>Forty\u2010five dogs were enrolled in a prospective study in order to compare the standard blood transfusion cross\u2010match technique to a commercial blood transfusion cross\u2010matching kit. These dogs were divided into 3 different groups that included 10 healthy dogs (control group), 11 anemic dogs in need of a blood transfusion, and 24 sick dogs that were previously transfused. Thirty\u2010five dogs diagnosed with anemia secondary to multiple disease processes were cross\u2010matched using both techniques. All dogs cross\u2010matched via the kit had a compatible major and minor result, whereas 16 dogs out of 45 (35%) had an incompatible cross\u2010match result when the standard laboratory technique was performed. The average time to perform the commercial kit was 15 minutes and this was 3 times shorter than the manual cross\u2010match laboratory technique that averaged 45\u201350 minutes to complete.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>While the gel\u2010based cross\u2010match kit is quicker and less technically demanding than standard laboratory cross\u2010match procedures, microagglutination and low\u2010grade hemolysis are difficult to identify by using the gel\u2010based kits. This could result in transfusion reactions if the gel\u2010based kits are used as the sole determinant of blood compatibility prior to transfusion. Based on our results, the standard manual cross\u2010match technique remains the gold standard test to determine blood transfusion compatibility.<\/jats:p><\/jats:sec>","DOI":"10.1111\/vec.12433","type":"journal-article","created":{"date-parts":[[2016,1,16]],"date-time":"2016-01-16T18:12:44Z","timestamp":1452967964000},"page":"262-268","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["Comparison of a commercial blood cross\u2010matching kit to the standard laboratory method for establishing blood transfusion compatibility in dogs"],"prefix":"10.1111","volume":"26","author":[{"given":"Leo Roa","family":"Guzman","sequence":"first","affiliation":[{"name":"Department of Emergency and Critical Care Eastern Iowa Veterinary Specialty Center  744 Capital Dr, SW Cedar Rapids IA 52402"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth","family":"Streeter","sequence":"additional","affiliation":[{"name":"Department of Emergency and Critical Care Eastern Iowa Veterinary Specialty Center  744 Capital Dr, SW Cedar Rapids IA 52402"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Allison","family":"Malandra","sequence":"additional","affiliation":[{"name":"Department of Emergency and Critical Care Eastern Iowa Veterinary Specialty Center  744 Capital Dr, SW Cedar Rapids IA 52402"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2016,1,15]]},"reference":[{"key":"e_1_2_8_2_1","first-page":"281","volume-title":"Textbook of Small Animal Critical Care Medicine","author":"Silverstein DC","year":"2009"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cvsm.2010.02.005"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cvsm.2013.03.007"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1476-4431.2010.00521.x"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-1676.2007.tb02961.x"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-1676.2011.0737.x"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1939-1676.1995.tb01080.x"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0195-5616(03)00093-7"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1476-4431.2009.00387.x"},{"key":"e_1_2_8_11_1","first-page":"27","volume-title":"Kirk and Bistner's Handbook of Veterinary Procedures and Emergency Treatment","author":"Ford R","year":"2006"},{"key":"e_1_2_8_12_1","doi-asserted-by":"crossref","first-page":"1386","DOI":"10.2460\/ajvr.2005.66.1386","article-title":"Comparison of various canine blood typing methods","volume":"66","author":"Giger U","journal-title":"Am J Vet Res 2005;"},{"key":"e_1_2_8_13_1","doi-asserted-by":"crossref","first-page":"132","DOI":"10.21307\/immunohematology-2019-728","article-title":"The gel test: sensitivity and specificity for unexpected antibodies to blood group antigens","volume":"13","author":"Judd WJ","year":"1997","journal-title":"Immunohematology"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.2460\/ajvr.73.2.213"}],"container-title":["Journal of Veterinary Emergency and Critical Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fvec.12433","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vec.12433","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T13:21:05Z","timestamp":1696166465000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/vec.12433"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,1,15]]},"references-count":13,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2016,3]]}},"alternative-id":["10.1111\/vec.12433"],"URL":"https:\/\/doi.org\/10.1111\/vec.12433","archive":["Portico"],"relation":{},"ISSN":["1479-3261","1476-4431"],"issn-type":[{"value":"1479-3261","type":"print"},{"value":"1476-4431","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,1,15]]},"assertion":[{"value":"2013-11-18","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2014-06-24","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2016-01-15","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}