{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,7,15]],"date-time":"2024-07-15T12:42:12Z","timestamp":1721047332787},"reference-count":11,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2019,3,5]],"date-time":"2019-03-05T00:00:00Z","timestamp":1551744000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Veterinary Ophthalmology"],"published-print":{"date-parts":[[2019,5]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Objective<\/jats:title><jats:p>The purpose of this study is to measure parameters of the anterior segment of normal feline eyes using a rotating Scheimpflug camera in young and adult cats.<\/jats:p><\/jats:sec><jats:sec><jats:title>Procedure<\/jats:title><jats:p>Sixteen domestic short\u2010haired (<jats:styled-content style=\"fixed-case\">DSH<\/jats:styled-content>) healthy cats (seven castrated males and nine spayed females) with a mean age of 17\u00a0months (<jats:styled-content style=\"fixed-case\">SD<\/jats:styled-content>\u00a0=\u00a03.5) were anesthetized. Cats were considered immature and adults if they were &lt; or \u226512\u00a0months of age, respectively. The keratometric values, the anterior chamber depth (<jats:styled-content style=\"fixed-case\">ACD<\/jats:styled-content>), and central corneal thickness (<jats:styled-content style=\"fixed-case\">CCT<\/jats:styled-content>) of the right eye of each animal were measured using a Pentacam Oculus topographer. The repeatability of the measures was assessed by calculating the coefficient of variation of the successive measures in cats (five repetitions per cat). We performed an<jats:styled-content style=\"fixed-case\">ANOVA<\/jats:styled-content>to test the effect of age on the parameters measures.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The mean<jats:styled-content style=\"fixed-case\">CCT<\/jats:styled-content>and<jats:styled-content style=\"fixed-case\">ACD<\/jats:styled-content>were 601.97\u00a0\u00b1\u00a038\u00a0\u03bcm and 5.27\u00a0\u00b1\u00a00.04\u00a0mm, respectively. No significant differences were observed between adult and young cat's measures. The average keratometric value was 39.6\u00a0\u00b1\u00a00.3\u00a0D. The mean average cylindrical error was 2.48\u00a0\u00b1\u00a00.35\u00a0D (43.75% \u201cagainst\u2010the\u2010rule\u201d astigmatism and 43.75% \u201coblique\u201d astigmatism).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The Oculus Pentacam under clinical conditions give<jats:styled-content style=\"fixed-case\">CCT<\/jats:styled-content>and<jats:styled-content style=\"fixed-case\">ACD<\/jats:styled-content>values very similar to those reported in previous studies. Corneal astigmatism measures were markedly elevated (&gt;2\u00a0D). Further studies with a larger population of cats of various breeds and ages are needed to confirm or refute these results, using a rotating Scheimpflug camera.<\/jats:p><\/jats:sec>","DOI":"10.1111\/vop.12650","type":"journal-article","created":{"date-parts":[[2019,3,6]],"date-time":"2019-03-06T06:10:12Z","timestamp":1551852612000},"page":"381-384","update-policy":"http:\/\/dx.doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Anterior segment parameters measured in young healthy cats using a rotating Scheimpflug camera"],"prefix":"10.1111","volume":"22","author":[{"given":"Marc","family":"Verneuil","sequence":"first","affiliation":[{"name":"Ophthalmology Clinique Veterinaire du Muy Le Muy France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maud","family":"Marsot","sequence":"additional","affiliation":[{"name":"Agence Nationale de S\u00e9curit\u00e9 Sanitaire University Paris Est Maisons Alfort France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charly","family":"Ruchon","sequence":"additional","affiliation":[{"name":"Orthoptist New Vision 14 Nice France"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2019,3,5]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.3109\/02713688409000794"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.02.021"},{"key":"e_1_2_9_4_1","unstructured":"Oculus PentacamR\/Pentacam HR\u2010User Guide: System for measuring and analyzing the front part of the eye.2015."},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/vop.12397"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1463-5216.2001.00198.x"},{"key":"e_1_2_9_7_1","doi-asserted-by":"crossref","first-page":"1339","DOI":"10.2460\/ajvr.1998.59.10.1339","article-title":"Experimental implantation of posterior chamber prototype intraocular lenses for the feline eye","volume":"59","author":"Gilger BC","year":"1998","journal-title":"Am J Vet Res"},{"key":"e_1_2_9_8_1","first-page":"306","article-title":"Corneal radius of curvature of the kitten and the cat","volume":"19","author":"Freeman RD","year":"1980","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"2","key":"e_1_2_9_9_1","doi-asserted-by":"crossref","first-page":"228","DOI":"10.2460\/ajvr.1993.54.02.228","article-title":"Corneal thickness measured by ultrasonic pachymetry in cats","volume":"54","author":"Gilger BC","year":"1993","journal-title":"Am J Vet Res"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/vop.12028"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.01.063"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00554-6"}],"container-title":["Veterinary Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fvop.12650","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vop.12650","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/vop.12650","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vop.12650","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,15]],"date-time":"2024-07-15T12:00:57Z","timestamp":1721044857000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/vop.12650"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3,5]]},"references-count":11,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2019,5]]}},"alternative-id":["10.1111\/vop.12650"],"URL":"https:\/\/doi.org\/10.1111\/vop.12650","archive":["Portico"],"relation":{},"ISSN":["1463-5216","1463-5224"],"issn-type":[{"value":"1463-5216","type":"print"},{"value":"1463-5224","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3,5]]},"assertion":[{"value":"2018-04-08","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-01-20","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-03-05","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}