{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T08:26:41Z","timestamp":1740126401409,"version":"3.37.3"},"reference-count":34,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2014,6,11]],"date-time":"2014-06-11T00:00:00Z","timestamp":1402444800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100004587","name":"Instituto de Salud Carlos III","doi-asserted-by":"crossref","award":["PI10\/02594)"],"award-info":[{"award-number":["PI10\/02594)"]}],"id":[{"id":"10.13039\/501100004587","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Vox Sanguinis"],"published-print":{"date-parts":[[2014,11]]},"abstract":"<jats:sec><jats:title>Background and Objectives<\/jats:title><jats:p>Inaccuracy of fingerstick haemoglobin compromises donor's health and losses blood donations. We evaluated the benefit of double haemoglobin screening with HemoCue.<\/jats:p><\/jats:sec><jats:sec><jats:title>Study Design and Methods<\/jats:title><jats:p>Blood donors underwent fingerstick screening by HemoCue and were driven for donation if capillary haemoglobin was within the regulatory range. Those failing were drawn venous blood and donated if their venous haemoglobin determined with HemoCue was acceptable.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Of 276\u00a0605 donor clinic visits, 10\u00a0011 (3\u00b76%) were assessed by two\u2010step haemoglobin screening using HemoCue, because of low (<jats:italic>n<\/jats:italic>\u00a0=\u00a09444) or high (<jats:italic>n<\/jats:italic>\u00a0=\u00a0567) capillary haemoglobin. Among these, 2561 (25\u00b76%) were deemed eligible [recovered donations]. The recovery rate was 23\u00b78% and 55\u00b70% among donors presenting with low and high capillary haemoglobin, respectively. In both categories of attempted donations, capillary and venous haemoglobin with HemoCue correlated significantly in recovered donors (<jats:italic>R<\/jats:italic><jats:sup>2<\/jats:sup>\u00a0\u2248\u00a00\u00b75\u20130\u00b77) but not in deferred visits (<jats:italic>R<\/jats:italic><jats:sup>2<\/jats:sup>\u00a0&lt;\u00a00\u00b715). Venous haemoglobin with HemoCue and by haematological analyzer significantly correlated in all donations attempts (<jats:italic>R<\/jats:italic><jats:sup>2<\/jats:sup>\u00a0\u2248\u00a00\u00b77). Donors presenting with low capillary haemoglobin showed small bias between capillary and venous haemoglobin by HemoCue (\u22122\u00b74\u00a0\u00b1\u00a06\u00b72\u00a0g\/l), fingerstick haemoglobin and venous haemoglobin with counter (1\u00b73\u00a0\u00b1\u00a07\u00b73\u00a0g\/l), and venous haemoglobin with HemoCue and counter (3\u00b77\u00a0\u00b1\u00a03\u00b79\u00a0g\/l). This bias was slightly greater in donors with high capillary haemoglobin (\u22127\u00b75\u00a0\u00b1\u00a07\u00b78, 13\u00b77\u00a0\u00b1\u00a07\u00b75, and 6\u00b72\u00a0\u00b1\u00a07\u00b75, respectively). Double haemoglobin screening by HemoCue reached an accuracy of 87\u00b73% for qualifying donors presenting with low fingerstick haemoglobin.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Double haemoglobin measurement with HemoCue [fingerstick and venous blood if required] is feasible and allows a significant recovery of blood donations.<\/jats:p><\/jats:sec>","DOI":"10.1111\/vox.12165","type":"journal-article","created":{"date-parts":[[2014,6,11]],"date-time":"2014-06-11T06:38:47Z","timestamp":1402468727000},"page":"343-350","source":"Crossref","is-referenced-by-count":2,"title":["Evaluation of two\u2010step haemoglobin screening with HemoCue for blood donor qualification in mobile collection sites"],"prefix":"10.1111","volume":"107","author":[{"given":"A.","family":"G\u00f3mez\u2010Sim\u00f3n","sequence":"first","affiliation":[{"name":"Centro Regional de Hemodonaci\u00f3n Servicio de Hematolog\u00eda y Oncolog\u00eda M\u00e9dica IMIB Universidad de Murcia Murcia Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E. M.","family":"Plaza","sequence":"additional","affiliation":[{"name":"Centro Regional de Hemodonaci\u00f3n Servicio de Hematolog\u00eda y Oncolog\u00eda M\u00e9dica IMIB Universidad de Murcia Murcia Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. M.","family":"Torregrosa","sequence":"additional","affiliation":[{"name":"Centro Regional de Hemodonaci\u00f3n Servicio de Hematolog\u00eda y Oncolog\u00eda M\u00e9dica IMIB Universidad de Murcia Murcia Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F.","family":"Ferrer\u2010Mar\u00edn","sequence":"additional","affiliation":[{"name":"Centro Regional de Hemodonaci\u00f3n Servicio de Hematolog\u00eda y Oncolog\u00eda M\u00e9dica IMIB Universidad de Murcia Murcia Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"I.","family":"S\u00e1nchez\u2010Guiu","sequence":"additional","affiliation":[{"name":"Centro Regional de Hemodonaci\u00f3n Servicio de Hematolog\u00eda y Oncolog\u00eda M\u00e9dica IMIB Universidad de Murcia Murcia Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"V.","family":"Vicente","sequence":"additional","affiliation":[{"name":"Centro Regional de Hemodonaci\u00f3n Servicio de Hematolog\u00eda y Oncolog\u00eda M\u00e9dica IMIB Universidad de Murcia Murcia Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M. L.","family":"Lozano","sequence":"additional","affiliation":[{"name":"Centro Regional de Hemodonaci\u00f3n Servicio de Hematolog\u00eda y Oncolog\u00eda M\u00e9dica IMIB Universidad de Murcia Murcia Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Rivera","sequence":"additional","affiliation":[{"name":"Centro Regional de Hemodonaci\u00f3n Servicio de Hematolog\u00eda y Oncolog\u00eda M\u00e9dica IMIB Universidad de Murcia Murcia Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2014,6,11]]},"reference":[{"volume-title":"Guide to the Preparation, Use and Quality Assurance of Blood Components","year":"2013","author":"Council of Europe Publishing","key":"e_1_2_7_2_1"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.2012.03820.x"},{"issue":"1","key":"e_1_2_7_4_1","first-page":"s11","article-title":"Women as whole blood donors: offers, donations and deferrals in the province of Huelva, south\u2010western Spain","volume":"12","author":"Madrona DP","year":"2014","journal-title":"Blood Transfus"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.transci.2013.06.020"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.2012.03562.x"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/tme.12046"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.2007.01292.x"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.2010.02881.x"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2458-12-1063"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.2008.01903.x"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.transci.2010.07.010"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.2012.03757.x"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.2003.00316.x"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.2008.02023.x"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.transci.2004.11.004"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.transci.2007.01.010"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/vox.12006"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.2011.03389.x"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.2307\/2529310"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1080\/08880010500456907"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-3148.2007.00738.x"},{"key":"e_1_2_7_24_1","first-page":"278","article-title":"Gender differences in giving blood: a review of the literature","volume":"8","author":"Bani M","year":"2010","journal-title":"Blood Transfus"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.4103\/0973-6247.98939"},{"key":"e_1_2_7_26_1","first-page":"385","article-title":"Evaluation of the validity of a rapid method for measuring high and low haemoglobin levels in whole blood donors","volume":"11","author":"Shahshahani HJ","year":"2013","journal-title":"Blood Transfus"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1423-0410.2009.01285.x"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.3343\/alm.2013.33.4.261"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.2011.03401.x"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.2012.03956.x"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1111\/vox.12033"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.2005.00574.x"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.2012.03784.x"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2288-13-62"},{"key":"e_1_2_7_35_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.2012.03655.x"}],"container-title":["Vox Sanguinis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fvox.12165","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vox.12165","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,29]],"date-time":"2023-09-29T14:27:09Z","timestamp":1695997629000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/vox.12165"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,6,11]]},"references-count":34,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2014,11]]}},"alternative-id":["10.1111\/vox.12165"],"URL":"https:\/\/doi.org\/10.1111\/vox.12165","archive":["Portico"],"relation":{},"ISSN":["0042-9007","1423-0410"],"issn-type":[{"type":"print","value":"0042-9007"},{"type":"electronic","value":"1423-0410"}],"subject":[],"published":{"date-parts":[[2014,6,11]]}}}