{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T03:05:43Z","timestamp":1784084743613,"version":"3.55.0"},"reference-count":8,"publisher":"Wiley","license":[{"start":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T00:00:00Z","timestamp":1783987200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T00:00:00Z","timestamp":1783987200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Vox Sanguinis"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background and Objectives<\/jats:title>\n                    <jats:p>Although blood component transfusion is a safe procedure, it remains vulnerable to preventable errors related to patient and product identification, protocol adherence and staff training. In Catalonia, significant heterogeneity persists in transfusion safety systems (TSS), spanning from basic procedures to advanced technologies, resulting in process variability and potential risks to patient safety. In response, the Banc de Sang i Teixits (BST) prioritized the development of a unified, proprietary TSS. This study aimed to design, evaluate and implement a robust, reliable system to promote a safer, homogeneous and sustainable transfusion environment across Catalonia.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>A longitudinal implementation study was conducted over 3\u2009years to oversee the development, user training, deployment, adaptation and maintenance of the new TSS. The project was structured into sequential phases, each involving specific tasks carried out by a multidisciplinary team of functional and technical professionals. Regular in\u2010person and virtual meetings were held throughout all phases to monitor progress and ensure alignment with project objectives.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The main outcome was the successful development and implementation of a proprietary\n                      <jats:styled-content style=\"fixed-case\">BST<\/jats:styled-content>\n                      TSS tailored to the needs of healthcare professionals. Key milestones included needs assessment, system specification, software development, comprehensive testing, structured staff training, hospital deployment and continuous monitoring to ensure proper adoption.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The newly developed system provides a robust, adaptable and clinically aligned solution designed \u2018by healthcare professionals for healthcare professionals\u2019. Despite organizational and technical challenges, a structured methodology, collaborative work and continuous validation ensured achievement of project objectives.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/vox.70325","type":"journal-article","created":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T02:45:06Z","timestamp":1784083506000},"source":"Crossref","is-referenced-by-count":0,"title":["Design, development and implementation of a new transfusion safety system at the\n                    <scp>Banc de Sang i Teixits<\/scp>\n                    in Catalonia (Spain)"],"prefix":"10.1111","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-5548-7977","authenticated-orcid":false,"given":"C.","family":"Ot\u00edn\u2010Aparicio","sequence":"first","affiliation":[{"name":"Banc de Sang i Teixits  Catalonia Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Aguilar\u2010Garc\u00eda","sequence":"additional","affiliation":[{"name":"Banc de Sang i Teixits  Catalonia Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Carbonell\u2010Cabeza","sequence":"additional","affiliation":[{"name":"Banc de Sang i Teixits  Catalonia Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. J.","family":"Prieto\u2010Larred","sequence":"additional","affiliation":[{"name":"Banc de Sang i Teixits  Catalonia Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Rodrigues\u2010Mendes","sequence":"additional","affiliation":[{"name":"Banc de Sang i Teixits  Catalonia Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,7,14]]},"reference":[{"key":"e_1_2_9_2_1","unstructured":"Oca\u00f1a P\u00e9rez\u2010Cerd\u00e1CM Barbero Hern\u00e1ndezI.Seguridad en el proceso transfusional en el paciente pedi\u00e1trico. El papel clave de la enfermer\u00eda. In: 33 Congreso Nacional de la Sociedad Espa\u00f1ola de Cuidados Intensivos Pedi\u00e1trico; 2018. Available from:https:\/\/secip.com\/images\/uploads\/2018\/06\/9.\u2010Seguridad\u2010del\u2010paciente.pdf. Last accessed 10 Jan 2026."},{"key":"e_1_2_9_3_1","volume-title":"Gu\u00eda sobre la transfusi\u00f3n de componentes sangu\u00edneos y derivados plasm\u00e1ticos","author":"Sociedad Espa\u00f1ola de Transfusi\u00f3n Sangu\u00ednea y Terapia Celular (SETS)","year":"2015"},{"key":"e_1_2_9_4_1","article-title":"Revisi\u00f3n de las medidas de seguridad durante el proceso transfusional","volume":"2","author":"Egea RC","year":"2021","journal-title":"Rev Sanit Invest"},{"key":"e_1_2_9_5_1","first-page":"172","volume-title":"XI Informe SEIS: Las TIC y la seguridad de los pacientes. Cap\u00edtulo VII: La seguridad transfusional y las tecnolog\u00edas de la informaci\u00f3n y la comunicaci\u00f3n","author":"Pereira A","year":"2016"},{"key":"e_1_2_9_6_1","volume-title":"Hemovigil\u00e0ncia: detecci\u00f3, an\u00e0lisi i registre de les reaccions adverses i incidents relacionats amb la transfusi\u00f3","author":"Ramiro L","year":"2022"},{"key":"e_1_2_9_7_1","volume-title":"Manual del sistema de seguretat transfusional Rhesus","author":"Mingo A","year":"2024"},{"key":"e_1_2_9_8_1","doi-asserted-by":"crossref","DOI":"10.1001\/jamanetworkopen.2024.43059","article-title":"Nurse burnout and patient safety, satisfaction, and quality of care: a systematic review and meta\u2010analysis","volume":"7","author":"Li LZ","year":"2024","journal-title":"JAMA Netw Open"},{"key":"e_1_2_9_9_1","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1177\/10775587241282403","article-title":"Changes in patient care experiences and the nurse work environment: a longitudinal study of U.S. hospitals","volume":"81","author":"Rosenbaum KEF","year":"2024","journal-title":"Med Care Res Rev"}],"container-title":["Vox Sanguinis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vox.70325","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/vox.70325","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vox.70325","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T02:45:08Z","timestamp":1784083508000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/vox.70325"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,14]]},"references-count":8,"alternative-id":["10.1111\/vox.70325"],"URL":"https:\/\/doi.org\/10.1111\/vox.70325","archive":["Portico"],"relation":{},"ISSN":["0042-9007","1423-0410"],"issn-type":[{"value":"0042-9007","type":"print"},{"value":"1423-0410","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,14]]},"article-number":"vox.70325"}}