{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T15:28:06Z","timestamp":1789658886033,"version":"4.0.1"},"reference-count":24,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2020,4,27]],"date-time":"2020-04-27T00:00:00Z","timestamp":1587945600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Vet Radiology Ultrasound"],"published-print":{"date-parts":[[2021,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>A Cocker Spaniel presented for recurrence of right forelimb lameness 33 months following transcondylar screw placement for a humeral intracondylar fissure. Elbow radiographs showed no evidence of implant\u2010related complications. Standard CT scale reconstruction images failed to demonstrate implant failure. Extended CT scale reconstruction images revealed a fracture through the mid\u2010portion of the screw. Revision surgery confirmed the implant failure; the screw was replaced and the lameness subsequently resolved. Extended CT scale reconstruction images allow detailed assessment of metal implants and should be considered when implant failure is suspected.<\/jats:p>","DOI":"10.1111\/vru.12864","type":"journal-article","created":{"date-parts":[[2020,4,28]],"date-time":"2020-04-28T05:31:17Z","timestamp":1588051877000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Use of an extended CT scale reconstruction to diagnose metal implant failure in a canine elbow"],"prefix":"10.1111","volume":"62","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2102-3722","authenticated-orcid":false,"given":"Jose","family":"Labrador","sequence":"first","affiliation":[{"name":"Southern Counties Veterinary Specialists Forest Corner Farm, Hangersley Ringwood Hampshire UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4803-0180","authenticated-orcid":false,"given":"Philip Georg","family":"Witte","sequence":"additional","affiliation":[{"name":"A30 Referrals, St Columb Major Cornwall UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6259-1035","authenticated-orcid":false,"given":"Andrew","family":"Holdsworth","sequence":"additional","affiliation":[{"name":"Southern Counties Veterinary Specialists Forest Corner Farm, Hangersley Ringwood Hampshire UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2020,4,27]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1748-5827.2001.tb02488.x"},{"key":"e_1_2_8_3_1","doi-asserted-by":"crossref","first-page":"966","DOI":"10.1111\/j.1532-950X.2011.00906.x","article-title":"Computed tomographic documentation of the natural progression of humeral intracondylar fissure in a cocker spaniel","volume":"40","author":"Farrell M","year":"2001","journal-title":"Vet Surg"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1748-5827.2010.00988.x"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1994.tb00509.x"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.3415\/VCOT-11-05-0066"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/jsap.12670"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.3415\/VCOT-09-08-0082"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2011.00847.x"},{"key":"e_1_2_8_10_1","first-page":"1","article-title":"Short\u2010 and long\u2010term outcome after transcondylar screw placement to treat humeral intracondylar fissure in dogs","author":"Chase D","year":"2019","journal-title":"Vet Surg"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2008.00370.x"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1148\/rg.2018170102"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1148\/rg.246045065"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2005.02.052"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20140473"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.13115"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.16.17684"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-011-2062-1"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2013.02.024"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-018-5414-2"},{"issue":"10","key":"e_1_2_8_21_1","first-page":"3892","article-title":"Effects of 16\u2010bit CT imaging scanning conditions for metal implants on radiotherapy dose distribution","volume":"15","author":"Liugang G","year":"2017","journal-title":"Oncol Lett"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4805102"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-200001000-00029"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v17i6.6153"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/vru.12146"}],"container-title":["Veterinary Radiology &amp; Ultrasound"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fvru.12864","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vru.12864","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/vru.12864","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vru.12864","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,4]],"date-time":"2024-08-04T20:21:50Z","timestamp":1722802910000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/vru.12864"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,27]]},"references-count":24,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2021,11]]}},"alternative-id":["10.1111\/vru.12864"],"URL":"https:\/\/doi.org\/10.1111\/vru.12864","archive":["Portico"],"relation":{},"ISSN":["1058-8183","1740-8261"],"issn-type":[{"value":"1058-8183","type":"print"},{"value":"1740-8261","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,27]]},"assertion":[{"value":"2019-11-20","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-02-13","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-04-27","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}