{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T10:17:07Z","timestamp":1783592227484,"version":"3.55.0"},"reference-count":25,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2017,11,29]],"date-time":"2017-11-29T00:00:00Z","timestamp":1511913600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Veterinary Surgery"],"published-print":{"date-parts":[[2018,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Objective<\/jats:title><jats:p>To describe a novel Sacroiliac Luxation Instrument System (SILIS\u2122) and its application in minimally invasive osteosynthesis (MIO) of sacroiliac luxations\/fractures (SIL\/F). The SILIS was designed to provide stable SIL\/F reduction and accurate sacral screw placement while reducing personnel exposure to ionizing radiation during intraoperative fluoroscopy.<\/jats:p><\/jats:sec><jats:sec><jats:title>Study design<\/jats:title><jats:p>Descriptive, proof of concept cadaveric study.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>A right SIL and a left SIL\/F were created on a Labrador Retriever that had died of natural causes. Bilateral sacroiliac lag screw fixation was performed under fluoroscopic guidance with the SILIS, which consists of dedicated reduction and fixation instruments rigidly linked to table\u2010bound 6\u2010axis arms.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Throughout surgery, the SILIS facilitated and maintained stable reduction and allowed accurate placement of a custom designed drill guide over the sacral body without the surgeon's manual holding of any reduction or fixation instruments. The surgical team was therefore able to step away from the C\u2010arm when acquiring fluoroscopic images, thus reducing exposure to radiation. Dorsoventral and craniocaudal screw deviation from an ideal trajectory ranged from 0.9\u00b0 to 3.8\u00b0. Both screws were fully located within the sacral body.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The SILIS addresses limitations associated with MIO of SIL\/F, including maintenance of reduction throughout surgery along with reliable and accurate sacral screw placement. Distance from the X\u2010ray source is the most effective protection against radiation. Use of the SILIS allows the surgical team to move away from the C\u2010arm during fluoroscopy, thereby reducing personnel exposure to dangerous direct and back\u2010scattered ionizing radiation.<\/jats:p><\/jats:sec>","DOI":"10.1111\/vsu.12746","type":"journal-article","created":{"date-parts":[[2017,11,29]],"date-time":"2017-11-29T17:38:58Z","timestamp":1511977138000},"page":"93-103","source":"Crossref","is-referenced-by-count":14,"title":["Minimally invasive lag screw fixation of sacroiliac luxation\/fracture using a dedicated novel instrument system: Apparatus and technique description"],"prefix":"10.1111","volume":"47","author":[{"given":"Lo\u00efc M.","family":"D\u00e9jardin","sequence":"first","affiliation":[{"name":"College of Veterinary Medicine Michigan State University East Lansing Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Albane H.","family":"Fauron","sequence":"additional","affiliation":[{"name":"College of Veterinary Medicine Michigan State University East Lansing Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laurent P.","family":"Guiot","sequence":"additional","affiliation":[{"name":"Bone &amp; Joint Center, ACCESS Specialty Animal Hospitals Los Angeles California"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reunan P.","family":"Guillou","sequence":"additional","affiliation":[{"name":"Bone &amp; Joint Center, ACCESS Specialty Animal Hospitals Los Angeles California"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2017,11,29]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1985.tb00841.x"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/B978-1-4377-2364-9.00024-0"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1053\/jvet.1999.0188"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.05.0479"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1186\/1750-1164-7-14"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-014-3499-8"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00247-004-1291-8"},{"key":"e_1_2_8_9_1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.14444\/2040","article-title":"A systematic review of minimally invasive sacroiliac joint fusion utilizing a lateral transarticular technique","volume":"9","author":"Heiney J","year":"2015","journal-title":"Int J Spine Surg."},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2008.00414.x"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.3415\/VCOT-11-05-0074"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.3415\/VCOT-16-02-0030"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-199708000-00002"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1093\/occmed\/kqi048"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-010-1393-6"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1985.tb00842.x"},{"key":"e_1_2_8_17_1","first-page":"46","article-title":"Surgical anatomy of the feline sacroiliac joint for lag screw fixation of sacroiliac fracture\u2010luxation","volume":"17","author":"Burger M","year":"2004","journal-title":"Vet Comp Orthop Traumatol."},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2009.00509.x"},{"key":"e_1_2_8_19_1","first-page":"447","article-title":"Radiation safety for radiologic technologists","volume":"83","author":"Bradley LA.","year":"2012","journal-title":"Radiol Technol."},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiographics.21.4.g01jl271033"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1136\/vr.102977"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1017\/S0263574797000672"},{"key":"e_1_2_8_23_1","doi-asserted-by":"crossref","first-page":"1240","DOI":"10.1097\/BRS.0b013e31824589d5","article-title":"Measurements of surgeons' exposure to ionizing radiation dose during intraoperative use of C\u2010arm fluoroscopy","volume":"37","author":"Lee K","year":"2012","journal-title":"Spine."},{"key":"e_1_2_8_24_1","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1302\/0301-620X.62B2.7364839","article-title":"Irradiation of the surgeon during pinning of femoral fractures","volume":"62","author":"Giachino AA","year":"1980","journal-title":"J Bone Joint Surg Br."},{"key":"e_1_2_8_25_1","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1007\/s002640050230","article-title":"Exposure of the surgeon to radiation during surgery","volume":"22","author":"Fuchs M","year":"1998","journal-title":"Int Orthop."},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-015-1207-z"}],"container-title":["Veterinary Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fvsu.12746","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vsu.12746","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,29]],"date-time":"2023-09-29T11:00:48Z","timestamp":1695985248000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/vsu.12746"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11,29]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,1]]}},"alternative-id":["10.1111\/vsu.12746"],"URL":"https:\/\/doi.org\/10.1111\/vsu.12746","archive":["Portico"],"relation":{},"ISSN":["0161-3499","1532-950X"],"issn-type":[{"value":"0161-3499","type":"print"},{"value":"1532-950X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,11,29]]}}}