{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T17:25:58Z","timestamp":1787505958678,"version":"build-2736575974"},"reference-count":37,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2018,8,9]],"date-time":"2018-08-09T00:00:00Z","timestamp":1533772800000},"content-version":"vor","delay-in-days":8,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"Arthrex Gmbh, Munich, Germany"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Veterinary Surgery"],"published-print":{"date-parts":[[2018,8]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To test the feasibility and safety of an arthroscopic imbrication of the medial glenohumeral ligament (MGHL) and the subscapularis tendon with knotless anchors in dogs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study design<\/jats:title>\n                    <jats:p>Cadaveric study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Sample population<\/jats:title>\n                    <jats:p>Ten limbs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Cranial and caudal arms of the MGHL were imbricated with a 2.9\u2010 or a 2.4\u2010mm knotless anchor. A horizontal mattress suture secured with a 3.5\u2010mm knotless anchor was used to imbricate the subscapularis tendon. Computed tomography measurements included (1) the bone stock around the anchors, (2) the angle between the anchor and the joint surface (insertion angle), and (3) the angle formed by lines tangent to the cortices of the bones (safety angle). Limbs were dissected to assess the position of anchors. Safety and insertion angles and bone stock were compared among anchors with a Kruskal\u2010Wallis test (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u2009.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Surgical repairs were achieved in all limbs, with only 2 of 30 anchors incorrectly placed, both in the glenoid. The safety angle of the humeral anchor (HA; median, 89\u00b0) was greater than that of the cranial glenoid anchor (CrGA;\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u2009.0017) and the caudal glenoid anchor (CdGA;\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u2009.001). The insertion angle of the HA (median, 68\u00b0) was also greater than that of the other anchors (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u2009.001 and\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u2009.001). The insertion angle of the CrGA (median, 26\u00b0) was greater (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u2009.0191) than that of the CdGA (median, 7\u00b0). All anchors were inserted at the MGHL and subscapularis footprint.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Arthroscopic imbrication of MGHL and subscapularis tendon was feasible. HA were safer to place than glenoid anchors.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical significance<\/jats:title>\n                    <jats:p>The results of this feasibility study justify further evaluation of the indications and outcomes of this technique in dogs with shoulder instability.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/vsu.12929","type":"journal-article","created":{"date-parts":[[2018,8,9]],"date-time":"2018-08-09T04:28:28Z","timestamp":1533788908000},"page":"817-826","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Feasibility and safety of arthroscopic medial glenohumeral ligament and subscapularis tendon repair with knotless anchors: A cadaveric study in dogs"],"prefix":"10.1111","volume":"47","author":[{"given":"Alexandra","family":"Penelas","sequence":"first","affiliation":[{"name":"Clinic for Small Animal Surgery, Small Animal Department, Vetsuisse Faculty University of Zurich Zurich Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas","family":"Gutbrod","sequence":"additional","affiliation":[{"name":"Clinic for Small Animal Surgery, Small Animal Department, Vetsuisse Faculty University of Zurich Zurich Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karolin","family":"K\u00fchn","sequence":"additional","affiliation":[{"name":"Clinic for Diagnostic Imaging, Small Animal Department, Vetsuisse Faculty University of Zurich Zurich Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Pozzi","sequence":"additional","affiliation":[{"name":"Clinic for Small Animal Surgery, Small Animal Department, Vetsuisse Faculty University of Zurich Zurich Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2018,8,9]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2007.00364.x"},{"key":"e_1_2_7_3_1","doi-asserted-by":"crossref","first-page":"503","DOI":"10.2460\/javma.1983.182.05.503","article-title":"Clinical results of surgical correction of shoulder luxation in dogs","volume":"182","author":"Vasseur PB","year":"1983","journal-title":"J Am Vet Med Assoc."},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2013.01110.x"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.5326\/15473317-34-1-42"},{"key":"e_1_2_7_6_1","first-page":"909","article-title":"Shoulder diseases in dogs","volume":"10","author":"Bardet JF","year":"2002","journal-title":"Vet Med."},{"key":"e_1_2_7_7_1","doi-asserted-by":"crossref","first-page":"352","DOI":"10.2460\/ajvr.1982.43.02.352","article-title":"Stability of the canine shoulder joint: an in vitro analysis","volume":"43","author":"Vasseur PB","year":"1982","journal-title":"Am J Vet Res."},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.2460\/ajvr.2004.65.1216"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1748-5827.2007.00340.x"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.3415\/VCOT-07-06-0058"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546503262188"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jht.2009.05.002"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2005.00070.x"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.ctsap.2007.09.006"},{"key":"e_1_2_7_15_1","unstructured":"DevittCM.Use of a lateral intra\u2010acromial portal and a craniomedial portal from \u201changing prep\u201d dorsally recumbent position for canine shoulder arthroscopy. Presented at: 31st Annual Veterinary Orthopedic Society Conference;2004; Big Sky MT."},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2005.00071.x"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200109000-00009"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0038-1632977"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11420-010-9187-7"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1177\/0095399703258735"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0038-1632698"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.2460\/javma.251.9.1042"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0037-1617376"},{"key":"e_1_2_7_24_1","unstructured":"DevittCM.Suture anchor techniques for medial shoulder imbrication. In: Proceedings of the Advanced Arthroscopy Arthrology Annual Meeting;2006; Naples FL."},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2003.11.029"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2009.05.006"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/0749-8063(95)90100-0"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2008.12.021"},{"key":"e_1_2_7_29_1","unstructured":"NagamotoHYN TakahashiH SanoH ItoiE.Is deadman's angle really advantageous in suture anchor insertion? A biomechanical study. Presented at: 60th Annual ORS meeting; March 15\u201018 2014; New Orleans LA."},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2014.07.010"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2007.00318.x"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2016.04.018"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.3944\/AOTT.2013.2935"},{"key":"e_1_2_7_34_1","unstructured":"Arthrex.SpeedFix\u2122 single row technique.https:\/\/www.arthrex.com\/shoulder\/speedfix-single-row-technique. Accessed June 8 2018."},{"key":"e_1_2_7_35_1","volume-title":"AO Principles of Fracture Management in the Dog and Cat","author":"Johnson AL","year":"2005"},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.3415\/VCOT-12-03-0034"},{"key":"e_1_2_7_37_1","first-page":"1058","article-title":"Arthroscopic subscapularis repair using single\u2010row mattress suture technique: clinical results and structural integrity","author":"Jeong JY","year":"2017","journal-title":"J Shoulder Elbow Surg."},{"key":"e_1_2_7_38_1","doi-asserted-by":"publisher","DOI":"10.1177\/2325967114556257"}],"updated-by":[{"DOI":"10.1111\/vsu.13146","type":"erratum","label":"Erratum","source":"publisher","updated":{"date-parts":[[2018,12,28]],"date-time":"2018-12-28T00:00:00Z","timestamp":1545955200000}}],"container-title":["Veterinary Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fvsu.12929","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vsu.12929","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,6]],"date-time":"2025-07-06T04:06:43Z","timestamp":1751774803000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/vsu.12929"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,8]]},"references-count":37,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2018,8]]}},"alternative-id":["10.1111\/vsu.12929"],"URL":"https:\/\/doi.org\/10.1111\/vsu.12929","archive":["Portico"],"relation":{},"ISSN":["0161-3499","1532-950X"],"issn-type":[{"value":"0161-3499","type":"print"},{"value":"1532-950X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,8]]},"assertion":[{"value":"2018-01-11","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-05-29","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-08-09","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}