{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T15:30:12Z","timestamp":1787239812083,"version":"build-2736575974"},"reference-count":22,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2021,8,4]],"date-time":"2021-08-04T00:00:00Z","timestamp":1628035200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/100007707","name":"University of California, Davis","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007707","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Veterinary Surgery"],"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To evaluate the accuracy of six depth gauges used in three tibial plateau leveling osteotomy (TPLO) plate holes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study design<\/jats:title>\n                    <jats:p>Ex vivo experimental study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Animals and sample population<\/jats:title>\n                    <jats:p>\n                      Cadaveric canine limbs (\n                      <jats:italic>n<\/jats:italic>\n                      \u00a0=\u00a010), one 25\u2010mm\u2010thick wood board, and one 33.8\u2010mm\u2010diameter polyvinyl chloride (PVC) pipe.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A TPLO was performed on 10 canine cadaveric pelvic limbs. Three 3.5\u2010mm plate holes were filled with screws. The remaining three plate holes: a compression hole, a combination compression\u2010locking hole, and a stacked combination compression\u2010locking hole were measured by three observers using six commercial depth gauges and using a micrometer as gold standard. The process was repeated on one wood board and one PVC pipe.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Bone measurements collected using two depth gauges with base diameter\u2009&lt;\u20095\u2009mm were smaller than measurements collected using the four depth gauges with base diameter\u2009&gt;\u20095.5\u2009mm (\n                      <jats:italic>p<\/jats:italic>\n                      ranging from &lt; .001 to .038). Mean depth gauge measurements were smaller than micrometer measurements by 2.20\u2009mm for the compression hole, 0.82\u2009mm for the combination hole, and 3.57\u2009mm for the stacked combination hole. Measurement differences among depth gauges were also present for wood board and PVC pipe measurements. Bone measurement variability between depth gauges was less for the combination and compression holes than for the stacked combination hole.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Depth gauges lacked accuracy. Measurements differed among gauges and measurement variability varied based on plate hole geometry.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical relevance<\/jats:title>\n                    <jats:p>Depth gauge measurement accuracy varies based on measuring devices and on 3.5\u2010mm plate hole geometry.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/vsu.13694","type":"journal-article","created":{"date-parts":[[2021,8,5]],"date-time":"2021-08-05T01:41:40Z","timestamp":1628127700000},"page":"1389-1397","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Evaluation of depth gauge accuracy in a canine tibial plateau leveling osteotomy model"],"prefix":"10.1111","volume":"50","author":[{"given":"David","family":"McChesney","sequence":"first","affiliation":[{"name":"Veterinary Surgical Center  Vienna Virginia USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anke","family":"Langenbach","sequence":"additional","affiliation":[{"name":"Veterinary Surgical Center  Vienna Virginia USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karalynn","family":"Kruger","sequence":"additional","affiliation":[{"name":"Veterinary Surgical Center  Vienna Virginia USA"},{"name":"Eastern Pennsylvania Veterinary Medical Center  Allentown Pennsylvania USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tanya","family":"C. Garcia","sequence":"additional","affiliation":[{"name":"Department of Surgical and Radiological Sciences and the Veterinary Orthopedic Research Laboratory, School of Veterinary Medicine University of California\u2010Davis  Davis California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6596-5928","authenticated-orcid":false,"given":"Denis J.","family":"Marcellin\u2010Little","sequence":"additional","affiliation":[{"name":"Department of Surgical and Radiological Sciences and the Veterinary Orthopedic Research Laboratory, School of Veterinary Medicine University of California\u2010Davis  Davis California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2021,8,4]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2005.00016.x"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.17236\/sat00113"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2013.12048.x"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2012.01053.x"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/vsu.12368"},{"key":"e_1_2_8_7_1","unstructured":"WatkinsJ&KowaleskiM.Veterinary. 4.5 mm LCP narrow and broad with stacked combination holes. AO Foundation TK System Innovations 1\/2010. 2010:52\u201054."},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.bot.0000161544.72757.95"},{"key":"e_1_2_8_9_1","first-page":"466","article-title":"Pullout strength variance among self\u2010tapping screws inserted to different depths","volume":"37","author":"Schoenfeld A","year":"2008","journal-title":"Am J Orthop (Belle Mead NJ)"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.88B12.17696"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/0363-5023(93)90310-Y"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1080\/10543400701329422"},{"key":"e_1_2_8_13_1","unstructured":"http:\/\/synthes.vo.llnwd.net\/o16\/LLNWMB8\/INT%20Mobile\/Synthes%20International\/Product%20Support%20Material\/legacy_Synthes_PDF\/102359-190131_LR.pdf Accessed February 19 2021."},{"key":"e_1_2_8_14_1","volume-title":"AO Surgery Reference","author":"Heim D","year":"2013"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1142\/S2424835518500030"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2018.04.011"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.3415\/VCOT-11-09-0122"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.forsciint.2015.12.022"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1999.00315.x"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11552-010-9316-2"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e318206eb65"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2009.00502.x"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1111\/vsu.13486"}],"container-title":["Veterinary Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vsu.13694","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/vsu.13694","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vsu.13694","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,29]],"date-time":"2023-08-29T17:15:27Z","timestamp":1693329327000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/vsu.13694"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,4]]},"references-count":22,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2021,10]]}},"alternative-id":["10.1111\/vsu.13694"],"URL":"https:\/\/doi.org\/10.1111\/vsu.13694","archive":["Portico"],"relation":{},"ISSN":["0161-3499","1532-950X"],"issn-type":[{"value":"0161-3499","type":"print"},{"value":"1532-950X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,8,4]]},"assertion":[{"value":"2021-03-18","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-07-20","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-08-04","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}