{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T01:23:37Z","timestamp":1790299417475,"version":"4.1.0"},"reference-count":29,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2023,7,18]],"date-time":"2023-07-18T00:00:00Z","timestamp":1689638400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Veterinary Surgery"],"published-print":{"date-parts":[[2024,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Objective<\/jats:title><jats:p>To report the use and feasibility of a self\u2010locking resorbable loop device for cryptorchidectomy.<\/jats:p><\/jats:sec><jats:sec><jats:title>Study design<\/jats:title><jats:p>Clinical prospective study.<\/jats:p><\/jats:sec><jats:sec><jats:title>Population<\/jats:title><jats:p>Twenty horses.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Horses suspected to have an abdominal testicle\/s after admission work\u2010up were enrolled. Horses were anesthetized in dorsal recumbency and a standard laparoscopic technique was performed. The looped device was inserted into the abdomen, glided around the testis\/cord and tightened. Then, the spermatic cord was transected prior testis removal. Surgical procedure details and remarks, perioperative complications and total surgical time were recorded. Short\u2010 (&gt;3\u2009weeks) and long\u2010term (&gt;6\u2009months) follow\u2010ups were obtained by telephone questionnaire.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Median total surgical time was 67\u2009min (range: 43\u2013189\u2009min) and significantly shortened after the first four horses. The loop device was easily glided around 13\/20 abdominal testes and required more time and technical skills around larger testes (\u22653\u2009years). Excellent intraoperative hemostasis was achieved in 17 horses. Three horses demonstrated mild intraoperative bleeding that required retightening, device replacement or adding a second device, respectively. Three horses developed mild postoperative hemoabdomen identified ultrasonographically and were successfully managed medically. Follow\u2010up revealed no significant complications related to the procedure. One horse was euthanized for colic 4\u2009months after surgery and one died of hemolytic shock 17\u2009months postoperatively.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>This device represents another method to perform equine cryptorchidectomy that requires minimal training and laparoscopic expertise but demands knowledge of the device and application to prevent complications.<\/jats:p><\/jats:sec><jats:sec><jats:title>Clinical significance<\/jats:title><jats:p>Laparoscopic cryptorchidectomy using this device is an alternative technique for horses &lt;3\u2009years.<\/jats:p><\/jats:sec>","DOI":"10.1111\/vsu.14001","type":"journal-article","created":{"date-parts":[[2023,7,19]],"date-time":"2023-07-19T03:08:53Z","timestamp":1689736133000},"page":"357-366","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Laparoscopic cryptorchidectomy using a resorbable self\u2010locking loop device in dorsally recumbent horses"],"prefix":"10.1111","volume":"53","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0476-6057","authenticated-orcid":false,"given":"Natacha","family":"Bonomelli","sequence":"first","affiliation":[{"name":"Department of Clinical Sciences College of Veterinary Medicine, University of Montreal  Saint Hyacinthe Quebec Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0978-836X","authenticated-orcid":false,"given":"Odd Viking","family":"H\u00f6glund","sequence":"additional","affiliation":[{"name":"Department of Clinical Sciences Swedish University of Agricultural Sciences  Uppsala Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0277-4977","authenticated-orcid":false,"given":"Alvaro G.","family":"Bonilla","sequence":"additional","affiliation":[{"name":"Tennessee Equine Hospital  Thompson's Station Tennessee USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2023,7,18]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.2042-3306.1986.tb03692.x"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cveq.2006.08.006"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/evj.13920"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/vsu.12624"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1998.tb00110.x"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1997.tb01507.x"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.2042-3306.1998.tb04468.x"},{"key":"e_1_2_8_9_1","volume-title":"A Resorbable Device for Ligation of Blood Vessels. Development, Assessment of Surgical Procedures and Clinical Evaluation, PhD Thesis","author":"H\u00f6glund O","year":"2012"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1177\/0885328211431018"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1186\/1756-0500-7-825"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13104-016-2042-2"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1136\/vr.104732"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1186\/1751-0147-53-47"},{"issue":"3","key":"e_1_2_8_15_1","first-page":"223","article-title":"Cystic duct pressures after ligation with a novel absorbable device in an ex vivo caprine cholecystectomy model","volume":"81","author":"Sundholm Tepper AJ","year":"2017","journal-title":"Can J Vet Res"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/vsu.13109"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/vsu.13623"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1177\/1553350617751293"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.2746\/042516406776866354"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.2460\/javma.246.7.777"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/evj.13483"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.2460\/javma.1992.201.11.1705"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1136\/vr.100601"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/vsu.13644"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2005.00101.x"},{"key":"e_1_2_8_26_1","first-page":"13","article-title":"Laparoscopic cryptorchidectomy in standing horse using the LigaSure technology (in Italian)","volume":"2","author":"Varasano V","year":"2008","journal-title":"Ippologia"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1556\/avet.2012.004"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.2460\/javma.246.8.885"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.3390\/ani10122446"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cveq.2008.09.003"}],"container-title":["Veterinary Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vsu.14001","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,16]],"date-time":"2024-04-16T12:24:08Z","timestamp":1713270248000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/vsu.14001"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,18]]},"references-count":29,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,2]]}},"alternative-id":["10.1111\/vsu.14001"],"URL":"https:\/\/doi.org\/10.1111\/vsu.14001","archive":["Portico"],"relation":{},"ISSN":["0161-3499","1532-950X"],"issn-type":[{"value":"0161-3499","type":"print"},{"value":"1532-950X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7,18]]},"assertion":[{"value":"2022-12-27","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-07-05","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-07-18","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}