{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,14]],"date-time":"2026-04-14T03:56:33Z","timestamp":1776138993602,"version":"3.50.1"},"reference-count":33,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2025,4,28]],"date-time":"2025-04-28T00:00:00Z","timestamp":1745798400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2025,4,28]],"date-time":"2025-04-28T00:00:00Z","timestamp":1745798400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Veterinary Surgery"],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To evaluate the feasibility of achieving bronchial blockade using a vascular balloon catheter under low\u2010cost semi\u2010flexible borescope guidance in dogs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study design<\/jats:title>\n                    <jats:p>Cadaveric pilot study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Sample population<\/jats:title>\n                    <jats:p>Canine cadavers (n\u2009=\u20097) weighing between 12.2 and 63\u2009kg.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Two participants attempted four different techniques to achieve bronchus blockade using a 10 Fr Coda catheter or an EZ\u2010blocker (EZ) under borescopic (B) or endoscopic (E) guidance. Placement success was confirmed via thoracoscopy. Success rate, procedure duration, and reasons of failure were recorded.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>B\u2010Coda catheter placement was possible on dogs intubated with a minimum 8.5\u2009mm size endotracheal tube (ETT). E\u2010EZ was unsuccessful with an 8.5 ETT and below and on some dogs bigger than 30\u2009kg.<\/jats:p>\n                    <jats:p>Excluding the failures due to size limitations of the devices, success rate during first attempt for the left side was 50% for B\u2010EZ and 75% for all other techniques. Right\u2010sided success was 50% for B\u2010EZ, 33% for B\u2010Coda, 66% for E\u2010EZ and 62% for E\u2010Coda. Malpositioning of the devices occurred twice as commonly under borescopic guidance.<\/jats:p>\n                    <jats:p>The techniques were all successful after up to two additional attempts. Time to achieve blockade was faster using endoscopic guidance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The catheter allowed bronchial occlusion in larger canine cadavers. The borescope allowed guidance without the size limitation of the endoscope.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical relevance<\/jats:title>\n                    <jats:p>The Coda catheter had no size limitation in comparison to the EZ blocker and could be analternative to it. A sterilized borescope may be an option when bronchoscope size is inappropriate for a patient.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/vsu.14223","type":"journal-article","created":{"date-parts":[[2025,4,29]],"date-time":"2025-04-29T01:04:20Z","timestamp":1745888660000},"page":"1387-1396","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Cadaveric evaluation of bronchial blockade using the Coda vascular catheter placed under Borescope guidance"],"prefix":"10.1111","volume":"54","author":[{"given":"Adrien","family":"Aertsens","sequence":"first","affiliation":[{"name":"College of Veterinary Medicine, Department of Veterinary Clinical Sciences Iowa State University  Ames Iowa"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Megan","family":"Macrae","sequence":"additional","affiliation":[{"name":"College of Veterinary Medicine, Department of Veterinary Clinical Sciences Iowa State University  Ames Iowa"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean\u2010Sebastien","family":"Palerme","sequence":"additional","affiliation":[{"name":"College of Veterinary Medicine, Department of Veterinary Clinical Sciences Iowa State University  Ames Iowa"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,4,28]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.2460\/ajvr.1991.52.10.1597"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13054-016-1220-x"},{"issue":"1","key":"e_1_2_7_4_1","first-page":"93","article-title":"Cadaveric evaluation of fluoroscopy\u2010assisted placement of one\u2010lung ventilation devices for video\u2010assisted thoracoscopic surgery in dogs","volume":"49","author":"Mayhew PD","year":"2020","journal-title":"Vet Surg."},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.2460\/ajvr.22.01.0009"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2014.12272.x"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2011.00979.x"},{"key":"e_1_2_7_8_1","first-page":"103","article-title":"Modern Bronchial Blockers in Thoracic Surgery","volume":"6","author":"Kreft T","year":"2016","journal-title":"Thoracic Anesthesia."},{"key":"e_1_2_7_9_1","first-page":"57","article-title":"Paediatric lung isolation. BJA","volume":"17","author":"Lethal M","year":"2017","journal-title":"Education."},{"key":"e_1_2_7_10_1","first-page":"311","volume-title":"Small animal laparoscopy and thoracoscopy","author":"Pascoe PJ","year":"2021"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.jvca.2013.05.029"},{"key":"e_1_2_7_12_1","unstructured":"Product Guide Vascular Therapies Fogarty\u00ae.Vol Edwards Lifescience. Irvine CA."},{"key":"e_1_2_7_13_1","unstructured":"Instructions for Use.Coda\u00ae and Coda\u00ae LP Balloon Catheters. Cook\u00ae Medical. Bloomington IN. in Vol."},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.3168\/jds.2019-17129"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tvjl.2012.06.053"},{"key":"e_1_2_7_16_1","first-page":"461","article-title":"Diagnosis of upper respiratory tract disorders in horses using a cheap, smartphone\u2010connected, flexible and steerable borescope","volume":"34","author":"Neuckermans Z","year":"2021","journal-title":"Equine Veterinary Education."},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13019-018-0767-9"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0123177"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.21037\/acs.2018.03.01"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1439-0264.2001.00301.x"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12070-016-1026-9"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X0203000512"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.4103\/0019-5049.118539"},{"key":"e_1_2_7_24_1","first-page":"1","article-title":"Can An Embolectomy Catheter Become a One Stop Solution for Lung Isolation in One Lung Ventilation?","volume":"8","author":"Jain A","year":"2020","journal-title":"Austin Journal of Anesthesia and Analgesia."},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X0002800510"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tacc.2014.04.003"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.3389\/fvets.2020.00039"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/0034-5687(78)90070-1"},{"key":"e_1_2_7_29_1","first-page":"23","volume-title":"Veterinary Anesthesia and Analgesia, The 5th of Lumb and Jones","author":"Craig M","year":"2015"},{"key":"e_1_2_7_30_1","volume-title":"Single\u2010Lung Ventilation, in StatPearls","author":"Mehrotra M","year":"2024"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bjps.2019.05.019"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.4097\/kja.22222"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1080\/17453054.2021.2008231"},{"key":"e_1_2_7_34_1","first-page":"42","article-title":"Biostable polyurethane elastomers","volume":"3","author":"Szycher M","year":"1992","journal-title":"Med Device Technol."}],"container-title":["Veterinary Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vsu.14223","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/vsu.14223","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vsu.14223","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,14]],"date-time":"2026-04-14T03:15:06Z","timestamp":1776136506000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/vsu.14223"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,28]]},"references-count":33,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2025,10]]}},"alternative-id":["10.1111\/vsu.14223"],"URL":"https:\/\/doi.org\/10.1111\/vsu.14223","archive":["Portico"],"relation":{},"ISSN":["0161-3499","1532-950X"],"issn-type":[{"value":"0161-3499","type":"print"},{"value":"1532-950X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,28]]},"assertion":[{"value":"2024-07-22","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-20","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-04-28","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}