{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,11]],"date-time":"2026-04-11T06:45:39Z","timestamp":1775889939726,"version":"3.50.1"},"reference-count":17,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2025,6,2]],"date-time":"2025-06-02T00:00:00Z","timestamp":1748822400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2025,6,2]],"date-time":"2025-06-02T00:00:00Z","timestamp":1748822400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Veterinary Surgery"],"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>The aim of the study was to determine if a novel arthrodesis technique for the equine metacarpophalangeal (MCP) joint using a human non\u2010contact bridging (NCB), polyaxial locking compression plate system has biomechanical and potential clinical advantages versus a traditional 5.5\u2009mm stainless steel locking compression plate (LCP) under biomechanical testing.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study design<\/jats:title>\n                    <jats:p>An ex vivo biomechanical equine cadaver study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Sample population<\/jats:title>\n                    <jats:p>A total of 11 MCP joints collected from adult Thoroughbred horses euthanized unrelated to musculoskeletal disease.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Each pair of MCP joints were randomly implanted with either an A LCP or NCB plate. Each construct was tested in cyclic loading followed by single cycle to failure in axial compression. Displacement at a target load of 1\u2009kN over 3600\u2009cycles at 1\u2009Hz was recorded prior to single cycle to failure testing.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      In cyclic testing, overall displacement recorded in constructs with the NCB plates was less than that of the LCP constructs with a mean (least square mean \u2013 LSM) difference of 0.33\u2009mm (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u2009.03). There was no difference between groups in single cycle testing for yield point (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u2009.55) and maximum load at failure (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u2009.95).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>While a significant difference was found between constructs during cyclic testing, LCP versus NCB constructs conferred no difference in stability in single cycle to failure testing.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical significance<\/jats:title>\n                    <jats:p>The increased stability of the NCB plate in cyclic loading, comparable failure strength to the LCP and versatility of polyaxial screws support further investigation for possible clinical use of the NCB plate for equine fetlock arthrodesis.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/vsu.14287","type":"journal-article","created":{"date-parts":[[2025,6,3]],"date-time":"2025-06-03T01:14:19Z","timestamp":1748913259000},"page":"605-612","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["An ex vivo comparison of mono\u2010versus polyaxial locking compression plates for metacarpophalangeal joint arthrodesis in the horse"],"prefix":"10.1111","volume":"55","author":[{"given":"Lawrence I. M.","family":"Kadic","sequence":"first","affiliation":[{"name":"Large Animal Clinical Sciences, College of Veterinary Medicine University of Florida  Gainesville Florida USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0723-8313","authenticated-orcid":false,"given":"Chin\u2010Chi","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Veterinary Clinical Sciences, School of Veterinary Medicine Louisiana State University  Baton Rouge Louisiana USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Britta S.","family":"Leise","sequence":"additional","affiliation":[{"name":"Department of Veterinary Clinical Sciences, School of Veterinary Medicine Louisiana State University  Baton Rouge Louisiana USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charles T.","family":"McCauley","sequence":"additional","affiliation":[{"name":"Department of Veterinary Clinical Sciences, School of Veterinary Medicine Louisiana State University  Baton Rouge Louisiana USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laura M.","family":"Riggs","sequence":"additional","affiliation":[{"name":"Department of Veterinary Clinical Sciences, School of Veterinary Medicine Louisiana State University  Baton Rouge Louisiana USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,6,2]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/B1-41-600123-9\/50087-5"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/vsu.13236"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2008.00375.x"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e31818896b3"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1002\/9781119380139"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0039-1698415"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/vsu.14036"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.3758\/BRM.41.4.1149"},{"key":"e_1_2_10_10_1","volume-title":"Fatigue and Durability of Structural Materials","author":"Halford GR","year":"2006"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.2460\/ajvr.1981.42.05.716"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.2460\/ajvr.2000.61.234"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.2042-3306.2011.00458.x"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.2460\/ajvr.2002.63.520"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.2042-3306.2010.00190.x"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.2746\/042516407X196555"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.14444\/2030"},{"key":"e_1_2_10_18_1","first-page":"256","article-title":"Comparative study of stainless steel and titanium limited contact\u2010dynamic compression plate application in the fractures of radius and ulna","volume":"12","author":"Joshi G","year":"2019","journal-title":"Med J Dr DY Patil Univ"}],"container-title":["Veterinary Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vsu.14287","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/vsu.14287","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vsu.14287","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,11]],"date-time":"2026-04-11T05:48:59Z","timestamp":1775886539000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/vsu.14287"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,2]]},"references-count":17,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,4]]}},"alternative-id":["10.1111\/vsu.14287"],"URL":"https:\/\/doi.org\/10.1111\/vsu.14287","archive":["Portico"],"relation":{},"ISSN":["0161-3499","1532-950X"],"issn-type":[{"value":"0161-3499","type":"print"},{"value":"1532-950X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,2]]},"assertion":[{"value":"2024-07-01","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-15","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-06-02","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}