{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T13:09:37Z","timestamp":1790082577755,"version":"4.0.1"},"reference-count":29,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2026,1,2]],"date-time":"2026-01-02T00:00:00Z","timestamp":1767312000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2026,1,2]],"date-time":"2026-01-02T00:00:00Z","timestamp":1767312000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Veterinary Surgery"],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To compare the biomechanical performance of adjunctive locking plating and double\u2010loop cerclage wiring in feline femora implanted with Zurich cementless total hip replacement (THR) stems.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study design<\/jats:title>\n                    <jats:p>Cadaveric biomechanical study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Animals<\/jats:title>\n                    <jats:p>\n                      Paired femora (\n                      <jats:italic>n<\/jats:italic>\n                      =\u200932) from 16 feline cadavers.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Two sequential studies were performed. First, femora implanted with Zurich cementless stems alone were compared with those stabilized by an adjunctive locking plate. Second, femora with locking plates were compared with those with cerclage wires. Constructs underwent cyclic axial and torsional loading followed by load\u2010to\u2010failure testing. Outcome measures included residual axial and torsional displacement, yield and ultimate forces and torques, energy absorption, and brittle failure frequency. Parameters were normalized to bone volume.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The locking plate group demonstrated substantially reduced residual torsional displacement and a trend toward lower axial displacement compared with the stem\u2010only group. Yield and ultimate failure strength did not differ. The cerclage group exhibited 36% greater ultimate axial displacement, 76% greater energy absorption, and 32% greater torsional displacement than the locking plate group. Normalization accentuated these differences. Cerclage wire fixation was associated with a lower frequency of brittle failure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Locking plates improved cyclic stability by reducing micromotion, while cerclage wires enhanced compliance and energy absorption under destructive loading. Neither method increased load to failure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical significance<\/jats:title>\n                    <jats:p>Adjunctive plate or cerclage wire provided biomechanical advantages in femora implanted with Zurich cementless THR stems. Locking plates may support implant stability, whereas cerclage wiring improves energy dissipation under supraphysiologic loading. Adjunctive fixation strategies should be tailored to patient\u2010specific femoral morphology and fracture risk in feline THR.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/vsu.70074","type":"journal-article","created":{"date-parts":[[2026,1,2]],"date-time":"2026-01-02T11:39:16Z","timestamp":1767353956000},"page":"781-790","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Plating and double\u2010loop cerclage wiring improve the mechanical performance of the femoral stem after\n                    <scp>Zurich<\/scp>\n                    cementless total hip replacement in cats"],"prefix":"10.1111","volume":"55","author":[{"given":"Clair","family":"Park","sequence":"first","affiliation":[{"name":"Virginia\u2013Maryland College of Veterinary Medicine  Blacksburg Virginia USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6596-5928","authenticated-orcid":false,"given":"Denis J.","family":"Marcellin\u2010Little","sequence":"additional","affiliation":[{"name":"JD Wheat Veterinary Orthopedic Research Laboratory, School of Veterinary Medicine, University of California\u2010Davis  Davis California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tanya","family":"Garcia\u2010Nolen","sequence":"additional","affiliation":[{"name":"JD Wheat Veterinary Orthopedic Research Laboratory, School of Veterinary Medicine, University of California\u2010Davis  Davis California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen J.","family":"Bresina","sequence":"additional","affiliation":[{"name":"KYON  Zurich Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Otto I.","family":"Lanz","sequence":"additional","affiliation":[{"name":"Virginia\u2013Maryland College of Veterinary Medicine  Blacksburg Virginia USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,1,2]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.3415\/VCOT-08-09-0087"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2011.00933.x"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1748-5827.2010.00953.x"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/vsu.13822"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0043-1761600"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2011.00919.x"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2010.00725.x"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2011.00940.x"},{"issue":"2","key":"e_1_2_7_10_1","first-page":"187","article-title":"Measurement of ground reaction forces in cats after total hip replacement","volume":"26","author":"Schweng G","year":"2024","journal-title":"J Feline Med Surg"},{"key":"e_1_2_7_11_1","first-page":"E1","volume-title":"Proceedings of the 18th Annual Scientific Meeting of the European College of Veterinary Surgeons","author":"Vezzoni A","year":"2009"},{"key":"e_1_2_7_12_1","first-page":"464","volume-title":"Proceedings of the 3rd World Veterinary Orthopedic Congress","author":"Vezzoni A","year":"2010"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2013.12018.x"},{"key":"e_1_2_7_14_1","volume-title":"Zurich Cementless Total Hip Replacement: Surgical Technique Guide","author":"Kyon AG","year":"2023"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(93)90018-A"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/vsu.13136"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.3415\/VCOT-07-08-0077"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1992.tb01705.x"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2010.00694.x"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.1996.tb01432.x"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199705000-00010"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.3109\/17453679209154809"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(98)90011-0"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2011.00858.x"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tvjl.2016.04.014"},{"issue":"7","key":"e_1_2_7_26_1","first-page":"1272","article-title":"The effect of prophylactic cerclage wires in primary total hip arthroplasty: a biomechanical and clinical analysis","volume":"27","author":"Waligora AC","year":"2012","journal-title":"J Arthroplasty"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000002864"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1111\/vsu.13756"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(99)90209-7"},{"key":"e_1_2_7_30_1","volume-title":"AO Principles of Fracture Management","author":"R\u00fcedi TP","year":"2005"}],"container-title":["Veterinary Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vsu.70074","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/vsu.70074","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/vsu.70074","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T04:48:35Z","timestamp":1778129315000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/vsu.70074"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,2]]},"references-count":29,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["10.1111\/vsu.70074"],"URL":"https:\/\/doi.org\/10.1111\/vsu.70074","archive":["Portico"],"relation":{},"ISSN":["0161-3499","1532-950X"],"issn-type":[{"value":"0161-3499","type":"print"},{"value":"1532-950X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,2]]},"assertion":[{"value":"2025-09-24","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-12-09","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-01-02","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}