{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T20:45:15Z","timestamp":1792701915284,"version":"4.5.0"},"reference-count":41,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2025,12,26]],"date-time":"2025-12-26T00:00:00Z","timestamp":1766707200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,12,26]],"date-time":"2025-12-26T00:00:00Z","timestamp":1766707200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["physoc.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Experimental Physiology"],"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Popular wearable devices that record a variety of health metrics, such as real\u2010time blood pressure (BP), could play a role in detecting hypertension in the population. The objective of this study was to compare the validity of the Huawei D device with that of the Omron M3 Intellisense device used by health workers. Sampling was used to obtain patients with normal and abnormal BP. Measurements were taken on the wrist via the Huawei Watch D, while measurements were made using the Omron M3 Intellisense (prevalidated) device used by experienced healthcare personnel at the health centre. A total of 100 normotensive and 100 hypertensive patients were analysed. The concordance statistics were calculated, and linear regression analysis was performed. The intraclass correlation coefficient was calculated to assess the concordance between the instruments used in the measurement and among the observers who made the measurements under a two\u2010factor mixed\u2010effects model, with calculation of the degree of absolute concordance in mean measurements. We found moderate results (systolic blood pressure (SBP) at 30 and 60\u00a0min and heart rate at 30\u00a0min) and nil for the rest [0.63 (0.36\u20130.78)\u00a0&lt;\u00a00.001]; in addition, the comparison of the two groups was verified by a Bland\u2013Altamn graph, in which the disparity of the results was observed. The Huawei D BP measuring device was shown to be relatively effective for measuring BP in hypertensive patients. However, the specificity of BP measurement in normotensive patients was not as reliable as in hypertensive patients.<\/jats:p>","DOI":"10.1113\/ep093286","type":"journal-article","created":{"date-parts":[[2025,12,26]],"date-time":"2025-12-26T13:10:54Z","timestamp":1766754654000},"page":"1746-1755","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Comparison of blood pressure measurements between the Huawei Watch D smartwatch application and the validated Omron M3 Intellisense device: Observational study"],"prefix":"10.1113","volume":"111","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2608-2019","authenticated-orcid":false,"given":"Jorge","family":"Vel\u00e1zquez Saornil","sequence":"first","affiliation":[{"name":"Facultad de Ciencias de la Salud. Departamento de Fisioterapia. Universidad Pontificia de Salamanca Salamanca Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ra\u00fal","family":"Frutos Llanes","sequence":"additional","affiliation":[{"name":"NEUMUSK Group, Facultad de Ciencias de la Salud, Departamento de Fisioterapia Universidad Cat\u00f3lica de \u00c1vila  \u00c1vila Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sonia","family":"Jim\u00e9nez Blanco","sequence":"additional","affiliation":[{"name":"NEUMUSK Group, Facultad de Ciencias de la Salud, Departamento de Fisioterapia Universidad Cat\u00f3lica de \u00c1vila  \u00c1vila Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4129-2084","authenticated-orcid":false,"given":"Zacar\u00edas","family":"S\u00e1nchez Mil\u00e1","sequence":"additional","affiliation":[{"name":"NEUMUSK Group, Facultad de Ciencias de la Salud, Departamento de Fisioterapia Universidad Cat\u00f3lica de \u00c1vila  \u00c1vila Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2616-8306","authenticated-orcid":false,"given":"Jos\u00e9 Manuel","family":"Barrag\u00e1n Casas","sequence":"additional","affiliation":[{"name":"NEUMUSK Group, Facultad de Ciencias de la Salud, Departamento de Fisioterapia Universidad Cat\u00f3lica de \u00c1vila  \u00c1vila Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rosario","family":"Pastor Mart\u00edn","sequence":"additional","affiliation":[{"name":"Facultad de Ciencias de la Salud. Departamento de Fisioterapia. Universidad Pontificia de Salamanca Salamanca Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ang\u00e9lica","family":"Camp\u00f3n Chekroun","sequence":"additional","affiliation":[{"name":"Departamento de Fisioterapia. Aquacheck, Physiotherapy clinic GESMUTE member C\u00e1ceres Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Rodr\u00edguez Sanz","sequence":"additional","affiliation":[{"name":"Facultad de Enfermer\u00eda, Fisioterapia y Podolog\u00eda Universidad Complutense de Madrid  Madrid Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,12,26]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2021.650929"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1159\/000330719"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.recesp.2013.08.003"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0b013e3283354b11"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1177\/003591577707001112"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2022.958212"},{"key":"e_1_2_10_8_1","volume-title":"Design and analysis of clinical experiments","author":"Fleiss J. L.","year":"2011"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41440-023-01215-z"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjsm.2010.079582"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.2169\/naika.96.86"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1249\/MSS.0b013e3182399f5e"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/00004872-200204000-00019"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/jch.13864"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40885-020-00158-8"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.14740\/cr1569"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0289052"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.2196\/14702"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.2196\/14686"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1037\/1082-989X.1.1.30"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.3390\/ijerph17186469"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjsports-2015-095947"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40885-024-00268-7"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ccl.2010.07.006"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11906-023-01286-w"},{"key":"e_1_2_10_26_1","volume-title":"Screening for High Blood Pressure in Adults: A Systematic Evidence Review for the U.S. Preventive Services Task Force","author":"Piper M. A.","year":"2014"},{"key":"e_1_2_10_27_1","volume-title":"Smartphone ownership is growing rapidly around the world, but not always equally","author":"Rosenberg S.","year":"2019"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2020.11.010"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.2147\/VHRM.S188089"},{"key":"e_1_2_10_30_1","first-page":"1","volume-title":"Handbook of global health","author":"Silberschmidt G.","year":"2021"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02832685"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1123\/jpah.8.7.1014"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1097\/HJH.0000000000003224"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000520"},{"key":"e_1_2_10_35_1","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000520"},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.1249\/mss.0b013e31815a51b3"},{"key":"e_1_2_10_37_1","doi-asserted-by":"publisher","DOI":"10.3758\/BF03200519"},{"key":"e_1_2_10_38_1","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.107.094193"},{"key":"e_1_2_10_39_1","doi-asserted-by":"publisher","DOI":"10.1038\/jhh.2010.37"},{"key":"e_1_2_10_40_1","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2022.923655"},{"issue":"11","key":"e_1_2_10_41_1","first-page":"843","article-title":"Validating the accuracy of a multifunctional smartwatch sphygmomanometer to monitor blood pressure","volume":"19","author":"Yi L.","year":"2022","journal-title":"Journal of Geriatric Cardiology"},{"key":"e_1_2_10_42_1","doi-asserted-by":"publisher","DOI":"10.1097\/MBP.0000000000000608"}],"container-title":["Experimental Physiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/physoc.onlinelibrary.wiley.com\/doi\/pdf\/10.1113\/EP093286","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/physoc.onlinelibrary.wiley.com\/doi\/full-xml\/10.1113\/EP093286","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/physoc.onlinelibrary.wiley.com\/doi\/pdf\/10.1113\/EP093286","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T19:52:21Z","timestamp":1789847541000},"score":1,"resource":{"primary":{"URL":"https:\/\/physoc.onlinelibrary.wiley.com\/doi\/10.1113\/EP093286"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,26]]},"references-count":41,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,4]]}},"alternative-id":["10.1113\/EP093286"],"URL":"https:\/\/doi.org\/10.1113\/ep093286","archive":["Portico"],"relation":{},"ISSN":["0958-0670","1469-445X"],"issn-type":[{"value":"0958-0670","type":"print"},{"value":"1469-445X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,26]]},"assertion":[{"value":"2025-09-06","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-11-25","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-12-26","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}