{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,2]],"date-time":"2026-02-02T20:58:17Z","timestamp":1770065897950,"version":"3.49.0"},"reference-count":17,"publisher":"ASME International","issue":"1","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2003,2,1]]},"abstract":"<jats:p>Previous echocardiographic techniques for quantifying valvular regurgitation (PISA) are limited by factors including uncertainties in orifice location and hemispheric convergence assumption. Using computational fluid dynamics simulations, we developed a new model for the estimation of orifice diameter and regurgitant volume without the aforementioned assumptions of the PISA technique. Using experimental data obtained from the in vitro flow model we successfully validated our new model. The model output (y) and reference (x) values were in close agreement (y=0.95x+0.38,r=0.96,error=1.68\u00b17.54% for the orifice diameter and y=1.18x\u22124.72,r=0.93,error=6.48\u00b116.81% for the regurgitant volume).<\/jats:p>","DOI":"10.1115\/1.1531111","type":"journal-article","created":{"date-parts":[[2003,2,25]],"date-time":"2003-02-25T18:46:08Z","timestamp":1046198768000},"page":"62-69","update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":1,"title":["A New Automated Method for the Quantification of Mitral Regurgitant Volume and Dynamic Regurgitant Orifice Area based on a Normalized Centerline Velocity Distribution using Color M-mode and Continuous Wave Doppler Imaging"],"prefix":"10.1115","volume":"125","author":[{"given":"Dimitri","family":"Deserranno","sequence":"first","affiliation":[{"name":"Cleveland Clinic Foundation, Department of Cardiology, Cardiovascular Imaging, 9500 Euclid Ave, Desk F15, Cleveland, OH\u200944195"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Neil L.","family":"Greenberg","sequence":"additional","affiliation":[{"name":"Cleveland Clinic Foundation, Department of Cardiology, Cardiovascular Imaging, 9500 Euclid Ave, Desk F15, Cleveland, OH\u200944195"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James D.","family":"Thomas","sequence":"additional","affiliation":[{"name":"Cleveland Clinic Foundation, Department of Cardiology, Cardiovascular Imaging, 9500 Euclid Ave, Desk F15, Cleveland, OH\u200944195"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mario J.","family":"Garcia","sequence":"additional","affiliation":[{"name":"Cleveland Clinic Foundation, Department of Cardiology, Cardiovascular Imaging, 9500 Euclid Ave, Desk F15, Cleveland, OH\u200944195"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"33","published-online":{"date-parts":[[2003,2,14]]},"reference":[{"key":"2019100609414573600_r1","doi-asserted-by":"crossref","unstructured":"Enriquez-Sarano, M., Tajik, A. J., Schaff, H. V., Orszulak, T. A., Bailey, K. R., and Frye, R. L., 1994, \u201cEchocardiographic Prediction of Survival after Surgical Correction of Organic Mitral Regurgitation,\u201d Circulation, 90, pp. 830\u2013837.","DOI":"10.1161\/01.CIR.90.2.830"},{"key":"2019100609414573600_r2","doi-asserted-by":"crossref","unstructured":"Dujardin, K. S., Enriquez-Sarano, M., Bailey, K. R., Nishimura, R. A., Seward, J. B., and Tajik, A. J., 1997, \u201cGrading of Mitral Regurgitation by Quantitative Doppler Echocardiography. Calibration by left Ventricular Angiography in Routine Clinical Practice,\u201d Circulation, 96, pp. 3409\u20133415.","DOI":"10.1161\/01.CIR.96.10.3409"},{"key":"2019100609414573600_r3","doi-asserted-by":"crossref","unstructured":"Thomas, J. D., Liu, C. M., Flachskampf, F. A., O\u2019Shea, J. P., Davidoff, R., and Weyman, A. E., 1990, \u201cQuantification of Jet Flow by Momentum Analysis. An In Vitro Color Doppler Flow Study,\u201d Circulation, 81, pp. 247\u2013259.","DOI":"10.1161\/01.CIR.81.1.247"},{"key":"2019100609414573600_r4","doi-asserted-by":"crossref","unstructured":"Zhang, J., Shiota, T., Shandas, R., Deng, Y. B., Weintraub, R., Paik, J., Liepmann, D., and Sahn, D. J., 1993, \u201cEffects of Adjacent Surfaces on Different Shapes of Regurgitant Jet Sizes: An In Vitro Study Using Color Doppler Imaging and Laser-illuminated Dye Visualization,\u201d J. Am. Coll. Cardiol., 22, pp. 1522\u20131528.","DOI":"10.1016\/0735-1097(93)90566-J"},{"key":"2019100609414573600_r5","doi-asserted-by":"crossref","unstructured":"Maciel, B. C., Moises, V. A., Shandas, R., Simpson, I. A., Beltran, M., Valdes-Cruz, L., and Sahn, D. J., 1991, \u201cEffect of Pressure and Volume of the Receiving Chamber on the Spatial Distribution of Regurgitant Jets as Imaged by Color Doppler Flow Mapping. An In Vitro study,\u201d Circulation, 83, pp. 605\u2013613.","DOI":"10.1161\/01.CIR.83.2.605"},{"key":"2019100609414573600_r6","doi-asserted-by":"crossref","unstructured":"Zhou, X., Jones, M., Shiota, T., Yamada, I., Teien, D., and Sahn, D. J., 1997, \u201cVena Contracta Imaged by Doppler Color Flow Mapping Predicts the Severity of Eccentric Mitral Regurgitation Better Than Color Jet Area: A Chronic Animal Study,\u201d J. Am. Coll. Cardiol., 30, pp. 1393\u20131398.","DOI":"10.1016\/S0735-1097(97)00304-5"},{"key":"2019100609414573600_r7","doi-asserted-by":"crossref","unstructured":"Buck, T., Mucci, R. A., Guerrerro, J. L., Holmvang, G., Handschumacher, M. D., and Levine, R. A., 2000, \u201cThe Power-velocity Integral at the Vena Contracta. A New Method for Direct Quantification of Regurgitant Volume Flow,\u201d Circulation, 102, pp. 1053\u20131061.","DOI":"10.1161\/01.CIR.102.9.1053"},{"key":"2019100609414573600_r8","doi-asserted-by":"crossref","unstructured":"Recusani, F., Bargiggia, G. S., Yoganathan, A. P., Raisaro, A., Valdes-Cruz, L. M., Sung, H. W., Bertucci, C., Gallati, M., Moises, V. A., and Simpson, I. A., 1991, \u201cA New Method for Quantification of Regurgitant Flow Rate Using Color Doppler Flow Imaging of the Flow Convergence Region Proximal to a Discrete Orifice. An In Vitro study,\u201d Circulation, 83, pp. 594\u2013604.","DOI":"10.1161\/01.CIR.83.2.594"},{"key":"2019100609414573600_r9","doi-asserted-by":"crossref","unstructured":"Rodriguez, L., Thomas, J. D., Monterroso, V., Weyman, A. E., Harrigan, P., Mueller, L. N., and Levine, R. A., 1993, \u201cValidation of the Proximal Flow Convergence Method. Calculation of Orifice Area in Patients with Mitral Stenosis,\u201d Circulation, 88, pp. 1157\u20131165.","DOI":"10.1161\/01.CIR.88.3.1157"},{"key":"2019100609414573600_r10","doi-asserted-by":"crossref","unstructured":"Pu, M., Griffin, B. P., Vandervoort, P. M., Leung, D. Y., Cosgrove, D. M., and Thomas, J. D., 1995, \u201cIntraoperative Validation of Mitral Inflow Determination by Transesophageal Echocardiography: Comparison of Single-plane, Biplane and Thermodilution Techniques,\u201d J. Am. Coll. Cardiol., 26, pp. 1047\u20131053.","DOI":"10.1016\/0735-1097(95)00259-2"},{"key":"2019100609414573600_r11","doi-asserted-by":"crossref","unstructured":"Cape, E. G., Thomas, J. D., Weyman, A. E., Yoganathan, A. P., and Levine, R. A., 1995, \u201cThree-dimensional Surface Geometry Correction is Required for Calculating Flow by the Proximal Isovelocity Surface Technique,\u201d J. Am. Soc. Echocardiogr, 8, pp. 585\u2013594.","DOI":"10.1016\/S0894-7317(05)80371-2"},{"key":"2019100609414573600_r12","doi-asserted-by":"crossref","unstructured":"Nozaki, S., Shandas, R., and DeMaria, A. N., 1997, \u201cRequirement for Accurate Measurement of Regurgitant Stroke Volume by Combined Continuous-wave Doppler and Color Doppler Flow Convergence Method,\u201d Am. Heart J., 133, pp. 19\u201328.","DOI":"10.1016\/S0002-8703(97)70243-6"},{"key":"2019100609414573600_r13","doi-asserted-by":"crossref","unstructured":"Shandas, R., Gharib, M., and Shan, D. J., 1995, \u201cNature of Flow Acceleration into a Finite-sized Orifice: Steady and Pulsatile Flow Studies on the Flow Convergence Region Using Simultaneous Ultrasound Doppler Flow Imaging and Laser Doppler Velocimetry,\u201d J. Am. Coll. Cardiol., 25, pp. 1199\u20131212.","DOI":"10.1016\/0735-1097(94)00533-V"},{"key":"2019100609414573600_r14","doi-asserted-by":"crossref","unstructured":"Deng, Y., Shiota, T., Shandas, R., Zhang, J., and Sahn, D. J., 1993, \u201cDetermination of the Most Appropiate Velocity Threshold for Applying Hemispheric Flow Convergence Equations to Calculate Flow Rate: Selected According to the Transorifice Pressure Gradient. Digital Computer Analysis of Doppler Color Flow Convergence Region,\u201d Circulation, 88, pp. 1699\u20131708.","DOI":"10.1161\/01.CIR.88.4.1699"},{"key":"2019100609414573600_r15","doi-asserted-by":"crossref","unstructured":"Schwammenthal, E., Chen, C., Benning, F., Block, M., Breithardt, G., and Levine, R. A., 1994, \u201cDynamics of Mitral Regurgitant Flow and Orifice Area. Physiologic Application of the Proximal Flow Convergence Method: Clinical Data and Experimental Testing,\u201d Circulation, 90, pp. 307\u2013322.","DOI":"10.1161\/01.CIR.90.1.307"},{"key":"2019100609414573600_r16","doi-asserted-by":"crossref","unstructured":"Utsunomiya, T., Ogawa, T., Doshi, R., Patel, D., Quan, M., Henry, W. L., and Gardin, J. M., 1991, \u201cDoppler Color Flow \u201cProximal Isovelocity Surface Area\u201d Method for Estimating Volume Flow Rate: Effects of Orifice Shape and Machine Factors,\u201d J. Am. Coll. Cardiol., 17(5), pp. 1103\u201311.","DOI":"10.1016\/0735-1097(91)90839-2"},{"key":"2019100609414573600_r17","doi-asserted-by":"crossref","unstructured":"Anayiotos, A. S., Perry, G. J., Myers, J. G., Green, D. W., Fan, P. H., and Nanda, N. C., 1995, \u201cA Numerical and Experimental Investigation of the Flow Acceleration Region Proximal to an Orifice,\u201d Ultrasound Med. Biol., 21(4), pp. 501\u2013516.","DOI":"10.1016\/0301-5629(94)00141-Y"}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/125\/1\/62\/5481740\/62_1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/125\/1\/62\/5481740\/62_1.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,6]],"date-time":"2019-10-06T13:42:10Z","timestamp":1570369330000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/125\/1\/62\/463792\/A-New-Automated-Method-for-the-Quantification-of"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,2,1]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2003,2,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.1531111","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2003,2,1]]}}}