{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T12:00:09Z","timestamp":1791028809317,"version":"4.1.0"},"reference-count":67,"publisher":"ASME International","issue":"2","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2004,4,1]]},"abstract":"<jats:p>Axisymmetric nonlinear finite-element analysis was used to simulate force-relaxation and creep data obtained during in vivo indentation of the residual limb soft tissues of six individuals with trans-tibial amputation [1]. The finite-element models facilitated estimation of an appropriate set of nonlinear viscoelastic material coefficients of extended James-Green-Simpson material formulation for bulk soft tissue at discrete, clinically relevant test locations. The results indicate that over 90% of the experimental data can be simulated using the two-term viscoelastic Prony series extension of James-Green-Simpson material formulation. This phenomenological material formulation could not, however, predict the creep response from relaxation experiments, nor the relaxation response from creep experiments [2\u20135]. The estimated material coefficients varied with test location and subject indicating that these coefficients cannot be readily extrapolated to other sites or individuals.<\/jats:p>","DOI":"10.1115\/1.1695575","type":"journal-article","created":{"date-parts":[[2004,5,4]],"date-time":"2004-05-04T22:02:54Z","timestamp":1083708174000},"page":"289-300","update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":25,"title":["Nonlinear Viscoelastic Material Property Estimation of Lower Extremity Residual Limb Tissues"],"prefix":"10.1115","volume":"126","author":[{"given":"Ergin","family":"To\u00a8nu\u00a8k","sequence":"first","affiliation":[{"name":"Middle East Technical University, Department of Mechanical Engineering, TR-06531\u2009Ankara-Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. Barbara","family":"Silver-Thorn","sequence":"additional","affiliation":[{"name":"Marquette University, Department of Biomedical Engineering, 1515 West Wisconsin Avenue, Milwaukee, Wisconsin\u200953233"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"33","published-online":{"date-parts":[[2004,5,4]]},"reference":[{"key":"2019100603505861800_r1","doi-asserted-by":"crossref","unstructured":"Silver-Thorn, M. B., Tonuk, E., and Kemp, J., 1999, \u201cIn Vivo Indentation of Lower Extremity Limb Soft Tissues,\u201d Proc. 1st BMES EMBS Conference., Atlanta GA, 1, p. 637.","DOI":"10.1109\/IEMBS.1999.802715"},{"key":"2019100603505861800_r2","doi-asserted-by":"crossref","unstructured":"Graf, B. K., Vanderby, R., Ulm, J. M., Rogalski, R. P., and Thielke, R. J., 1994, \u201cEffect of Preconditioning on the Viscoelastic Response of Primate Patellar Tendon,\u201d Arthroscopy, 10, pp. 90\u201396.","DOI":"10.1016\/S0749-8063(05)80298-1"},{"key":"2019100603505861800_r3","doi-asserted-by":"crossref","unstructured":"Thornton, G. M., Oliynyk, M. A., Frank, C. B., and Shrive, N. G., 1997, \u201cLigament Creep cannot be Predicted from Stress Relaxation at Low Stress: A Biomechanical Study of the Rabbit Medial Collateral Ligament,\u201d JBJS, 15, pp. 652\u2013656.","DOI":"10.1002\/jor.1100150504"},{"key":"2019100603505861800_r4","doi-asserted-by":"crossref","unstructured":"Lakes, R. S., and Vanderby, R., 1999, \u201cInterrelation of Creep and Relaxation: A Modeling Approach for Ligaments,\u201d J. Biomech. Eng., 121, pp. 612\u2013615.","DOI":"10.1115\/1.2800861"},{"key":"2019100603505861800_r5","doi-asserted-by":"crossref","unstructured":"Provenzo, P., Lakes, R., Keenan, T., and Vanderby, R., 2001, \u201cNonlinear Ligament Viscoelasticity,\u201d Ann. Biomed. Eng., 29, pp. 908\u2013914.","DOI":"10.1114\/1.1408926"},{"key":"2019100603505861800_r6","unstructured":"Hoaglund, F. T., Jergesen, H. E., Wilson, L., Lamoreux, L. W., and Roberts, R., 1983, \u201cEvaluation of the Problems and Needs of Veteran Lower-Limb Amputees in the San Francisco Bay Area during the Period 1977\u20131980,\u201d J. Rehabil. Res. Dev., 20, pp. 57\u201371."},{"key":"2019100603505861800_r7","doi-asserted-by":"crossref","unstructured":"Sanders, J. E. , 1995, \u201cInterface Mechanics in External Prosthetics: Review of Interface Stress Measurement Techniques,\u201d Med. Biol. Eng. Comput., 33, pp. 509\u2013516.","DOI":"10.1007\/BF02522507"},{"key":"2019100603505861800_r8","unstructured":"Silver-Thorn, M. B., Steege, J. W., and Childress, D. S., 1996, \u201cA Review of Prosthetic Interface Stress Investigations,\u201d J. Rehabil. Res. Dev., 33, pp. 253\u2013266."},{"key":"2019100603505861800_r9","doi-asserted-by":"crossref","unstructured":"Zachariah, S. G., and Sanders, J. E., 1996, \u201cInterface Mechanics in Lower-Limb External Prosthetics: a Review of Finite Element Methods,\u201d IEEE Trans. Rehabil. Eng., 4, pp. 288\u2013302.","DOI":"10.1109\/86.547930"},{"key":"2019100603505861800_r10","doi-asserted-by":"crossref","unstructured":"Zhang, M., Mak, A. F. T., and Roberts, V. C., 1998, \u201cFinite Element Modelling of a Residual Lower-Limb in a Prosthetic Socket: A Survey on the Development in the First Decade,\u201d Med. Eng. Phys., 20, pp. 360\u2013373.","DOI":"10.1016\/S1350-4533(98)00027-7"},{"key":"2019100603505861800_r11","unstructured":"Steege, J. W., Schnur, D. S., and Childress, D. S., 1987, \u201cEstimation of Pressure at the Below-Knee Socket by Finite Element Analysis,\u201d ASME-BED, 4, pp. 39\u201343."},{"key":"2019100603505861800_r12","unstructured":"Steege, J. W., Schnur, D. S., Van Vorhis, L. R., and Rovick, J. S., 1987, \u201cFinite Element Analysis as a Method of Pressure Estimation at the Below-Knee Socket Interface\u201d Proc. 10th Ann. RESNA Conf., San Jose, CA, pp. 814\u2013816."},{"key":"2019100603505861800_r13","unstructured":"Steege, J. W., and Childress, D. S., 1988, \u201cFinite Element Estimation of Pressure at the Below-Knee Socket Interface,\u201d Report of ISPO Workshop on CAD\/CAM in Prosthetics and Orthotics, Seattle, WA, pp. 71\u201382."},{"key":"2019100603505861800_r14","doi-asserted-by":"crossref","unstructured":"Zhang, M., Lord, M., Turner-Smith, A. R., and Robert, V. C., 1995, \u201cDevelopment of a Non-Linear Finite Element Modeling of the Below-Knee Prosthetic Socket Interface,\u201d Methods Exp. Phys., 17, pp. 559\u2013566.","DOI":"10.1016\/1350-4533(95)00002-5"},{"key":"2019100603505861800_r15","unstructured":"Silver-Thorn, M. B., and Childress, D. S., 1996, \u201cParametric Analysis Using Finite Element Method to Investigate Prosthetic Interface Stresses for Persons with Trans-Tibial Amputation,\u201d J. Rehabil. Res. Dev., 33, pp. 227\u2013238."},{"key":"2019100603505861800_r16","unstructured":"Vetrano, S. L., and Silver-Thorn, M. B., 1997, \u201cAnalysis of Residual Limb Bulk Soft Tissue Behavior Using Nonlinear Finite Element Methods,\u201d ASME-BED, 35, pp. 201\u2013202."},{"key":"2019100603505861800_r17","doi-asserted-by":"crossref","unstructured":"Commean, P. K., Smith, K. E., Vannier, M. W., Szabo, B. A., and Actis, L. R., 1997, \u201cFinite Element Modeling and Experimental Verification of Lower Extremity Shape Change under Load,\u201d J. Biomech., 30, pp. 531\u2013536.","DOI":"10.1016\/S0021-9290(96)00179-0"},{"key":"2019100603505861800_r18","unstructured":"Houston, V. L., Luo, G., Mason, C. P., Beattie, A. C., LaBlanc, K. P., and Garbarini, M., 1997, \u201cTissue Biomechanical Studies for Prosthetic Socket Design,\u201d ASME-BED, 35, pp. 245\u2013246."},{"key":"2019100603505861800_r19","unstructured":"Fisher, C., Simpson, G., and Reynolds, D., 1999, \u201cDevelopment of a Finite Element Model of a Transtibial Socket Liner \u2013 An Initial Study,\u201d Biomed. Sci. Instrum., 35, pp. 39\u201344."},{"key":"2019100603505861800_r20","doi-asserted-by":"crossref","unstructured":"Zachariah, S. G., and Sanders, J. E., 1999, \u201cPre-Stresses due to Trans-Tibial Socket Donning: A Nonlinear Finite Element Analysis with Contact,\u201d Proc. 1st BMES EMBS Conference., Atlanta GA, 1, p. 648.","DOI":"10.1109\/IEMBS.1999.802726"},{"key":"2019100603505861800_r21","unstructured":"Seguchi, Y., Tanaka, M., Akazawa, Y., Nakagawa, A., and Kitayama, A., 1989, \u201cFinite Element Analysis and Load Identification of Above-Knee Prosthesis Socket,\u201d 4th Int. ANSYS Conference, Pt. 2, pp. 12.31\u201312.44."},{"key":"2019100603505861800_r22","unstructured":"Brennan, J. M., and Childress, D. S., 1991, \u201cFinite Element and Experimental Investigation of Above-Knee Amputee Limb\/Prosthesis Systems: A Comparative Study,\u201d ASME-BED, 20, pp. 547\u2013550."},{"key":"2019100603505861800_r23","unstructured":"Mak, A. F. T., Yu, Y. M., Hong, M. L., and Chan, C., 1992, \u201cFinite Element Models for Analyses of Stresses within Above-Knee Stumps,\u201d Proc. 7th World Congress of ISPO, pp. 147\u2013148."},{"key":"2019100603505861800_r24","doi-asserted-by":"crossref","unstructured":"Zhang, M., and Mak, A. F. T., 1996, \u201cFinite Element Analysis of the Load Transfer between an Above-Knee Residual Limb and Its Prosthetic Socket\u2014Roles of Interface Friction and Distal-End Boundary Conditions,\u201d IEEE Trans. Rehabil. Eng., 4, pp. 337\u2013346.","DOI":"10.1109\/86.547935"},{"key":"2019100603505861800_r25","doi-asserted-by":"crossref","unstructured":"Douglas, T. S., Solomonidis, S. E., Lee, V. S. P., and Spence, W. D., 1997, \u201cAutomatic Boundary Extraction from Magnetic Resonance Images of the Residual Limb of a Trans-Femoral Amputee,\u201d Proc. 19th Ann. Conf. EMBS, 2, pp. 577\u2013579.","DOI":"10.1109\/IEMBS.1997.757675"},{"key":"2019100603505861800_r26","doi-asserted-by":"crossref","unstructured":"Tanaka, M., Akazawa, Y., Nakagawa, A., and Kitayama, I., 1997, \u201cIdentification of Pressure Distribution at the Socket Interface of an Above-Knee Prosthesis,\u201d Adv. Eng. Software, 28, pp. 379\u2013384.","DOI":"10.1016\/S0965-9978(96)00048-8"},{"key":"2019100603505861800_r27","doi-asserted-by":"crossref","unstructured":"Zhang, M., Mak, A. F. T., and Mak, J., 1998, \u201cAir Cushion Action at the Distal End of Above-Knee Stump with a Prosthetic Socket,\u201d Proc. 20th Ann. Conf. EMBS, 5, pp. 2754\u20132756.","DOI":"10.1109\/IEMBS.1998.745248"},{"key":"2019100603505861800_r28","unstructured":"Vannah, W. M., and Childress, D. S., 1996, \u201cIndentor Tests and Finite Element Modeling of Bulk Muscular Tissue In Vivo,\u201d J. Rehabil. Res. Dev., 33, pp. 239\u2013252."},{"key":"2019100603505861800_r29","doi-asserted-by":"crossref","unstructured":"Silver-Thorn, M. B. , 1999, \u201cIn Vivo Indentation of Lower Extremity Soft Tissues,\u201d IEEE Trans. Rehabil. Eng., 7, pp. 268\u2013277.","DOI":"10.1109\/86.788464"},{"key":"2019100603505861800_r30","doi-asserted-by":"crossref","unstructured":"Zheng, Y. P., and Mak, A. F. T., 1999, \u201cExtraction of Quasi-Linear Viscoelastic Coefficients for Lower Limb Soft Tissues from Manual Indentation Experiment,\u201d J. Biomech. Eng., 121, pp. 330\u2013339.","DOI":"10.1115\/1.2798329"},{"key":"2019100603505861800_r31","unstructured":"Fung, Y. C. B., 1972, \u201cStress-Strain History Relations of Soft Tissues in Simple Elongation,\u201d Biomechanics: Its Foundations and Objectives, Fung, Perrone and Anliker eds., Prentice Hall Inc. Inglewood, NJ, pp. 181\u2013208."},{"key":"2019100603505861800_r32","doi-asserted-by":"crossref","unstructured":"Sauren, A. A. H. J., and Rousseau, E. P. M., 1983, \u201cA Concise Sensitivity Analysis of the Quasi-Linear Viscoelastic Model Proposed by Fung,\u201d J. Biomech. Eng., 105, pp. 92\u201395.","DOI":"10.1115\/1.3138391"},{"key":"2019100603505861800_r33","doi-asserted-by":"crossref","unstructured":"Dortmans, L. J. M. G., Sauren, A. A. H. J., and Rousseau, E. P. M., 1984, \u201cCoefficient Estimation Using Quasi-Linear Viscoelastic Model Proposed by Fung,\u201d J. Biomech. Eng., 106, pp. 198\u2013203.","DOI":"10.1115\/1.3138483"},{"key":"2019100603505861800_r34","doi-asserted-by":"crossref","unstructured":"Nigul, I, and Nigul, U., 1987, \u201cOn Algorithms of Evaluation of Fung\u2019s Relaxation Function Coefficients,\u201d J. Biomech. Eng., 20, pp. 343\u2013352.","DOI":"10.1016\/0021-9290(87)90042-X"},{"key":"2019100603505861800_r35","doi-asserted-by":"crossref","unstructured":"Johnnson, G. A., Livesay, G. A., Woo, S. L. Y., and Rajagopal, K. R., 1996, \u201cA Single Integral Finite Strain Viscoelastic Model of Ligaments and Tendons,\u201d J. Biomech. Eng., 118, pp. 221\u2013226.","DOI":"10.1115\/1.2795963"},{"key":"2019100603505861800_r36","doi-asserted-by":"crossref","unstructured":"Miller, K., and Chinzei, K., 1997, \u201cConstitutive Modelling of Brain Tissue: Experiment and Theory,\u201d J. Biomech. Eng., 30, pp. 1115\u20131121.","DOI":"10.1016\/S0021-9290(97)00092-4"},{"key":"2019100603505861800_r37","doi-asserted-by":"crossref","unstructured":"Bowen, R. M. , 1980, \u201cIncompressible Porous Media Models by the Use of the Theory of Mixtures,\u201d Int. J. Eng. Sci., 18, pp. 1129\u20131148.","DOI":"10.1016\/0020-7225(80)90114-7"},{"key":"2019100603505861800_r38","doi-asserted-by":"crossref","unstructured":"Spilker, R. L., and Suh, J. K., 1990, \u201cFormulation and Evaluation of a Finite Element Model for the Biphasic Model of Soft Tissues,\u201d Comput. Struct., 35, pp. 425\u2013439.","DOI":"10.1016\/0045-7949(90)90067-C"},{"key":"2019100603505861800_r39","doi-asserted-by":"crossref","unstructured":"Simon, B. R. , 1992, \u201cMultiphase Poroelastic Finite Element Models of Soft Tissue Structures,\u201d Appl. Mech. Rev., 45, pp. 191\u2013218.","DOI":"10.1115\/1.3121397"},{"key":"2019100603505861800_r40","doi-asserted-by":"crossref","unstructured":"Liable, J. P., Pflaster, D., Simon, B. R., Krag, M. H., Pope, M., and Haugh, L. D., 1994, \u201cA Dynamic Coefficient Estimation Procedure for Soft Tissue Using a Poroelastic Finite Element Model,\u201d J. Biomech. Eng., 116, pp. 19\u201329.","DOI":"10.1115\/1.2895699"},{"key":"2019100603505861800_r41","doi-asserted-by":"crossref","unstructured":"Butler, S. L., Kohles, S. S., Thielke, R. J., Chen, C., and Vanderby, Jr., R., 1997, \u201cInterstitial Fluid Flow in Tendons or Ligaments: A Porous Medium Finite Element Simulation,\u201d Med. Biol. Eng. Comput., 35, pp. 742\u2013746.","DOI":"10.1007\/BF02510987"},{"key":"2019100603505861800_r42","doi-asserted-by":"crossref","unstructured":"Simon, B. R., Kaufman, M. V., Liu, J., and Baldwin, A. L., 1998, \u201cPorohyperelastic-Transport-Swelling Theory Material Properties and Finite Element Models for Large Arteries,\u201d Int. J. Solids Struct., 35, pp. 5021\u20135031.","DOI":"10.1016\/S0020-7683(98)00107-3"},{"key":"2019100603505861800_r43","doi-asserted-by":"crossref","unstructured":"Iding, R. H., Pister, K. S., and Taylor, R. L., 1974, \u201cIdentification of Nonlinear Elastic Solids by a Finite Element Method,\u201d Comput. Methods Appl. Mech. Eng., 4, pp. 121\u2013142.","DOI":"10.1016\/0045-7825(74)90030-9"},{"key":"2019100603505861800_r44","doi-asserted-by":"crossref","unstructured":"Lin, H. S., Liu, Y. K., Ray, G., and Nikravesh, P. E., 1978, \u201cSystems Identification for Material Properties of the Intervertebral Joint,\u201d J. Biomech., 11, pp. 1\u201314.","DOI":"10.1016\/0021-9290(78)90038-6"},{"key":"2019100603505861800_r45","doi-asserted-by":"crossref","unstructured":"Wineman, A., Wilson, D., and Melvin, J. W., 1979, \u201cMaterial Identification of Soft Tissue Using Membrane Inflation,\u201d J. Biomech., 12, pp. 841\u2013850.","DOI":"10.1016\/0021-9290(79)90169-6"},{"key":"2019100603505861800_r46","unstructured":"Ray, G., and Ghista, D. N., 1980, \u201cA Direct Computational Algorithm to Estimate In Vivo Constitutive Properties of Some Cardiovascular Structures,\u201d Finite Elements in Biomechanics, B. R. Simon, ed., Univ. of Arizona, 2, pp. 623\u2013637."},{"key":"2019100603505861800_r47","unstructured":"Pao, Y. C., 1982, \u201cFinite Elements in Stress Analysis and Estimation of Mechanical Properties of Working Heart,\u201d Finite Elements in Biomechanics, R. H. Gallagher, B. R. Simon and P. C. Johnson, J. F. Gross, Ed. Wiley, 127-153."},{"key":"2019100603505861800_r48","doi-asserted-by":"crossref","unstructured":"Guccione, J. M., McCulloch, A. D., and Waldman, L. K., 1991, \u201cPassive Material Properties of Intact Ventricular Myocardium Determined from a Cylindrical Model,\u201d J. Biomech. Eng., 113, pp. 42\u201355.","DOI":"10.1115\/1.2894084"},{"key":"2019100603505861800_r49","doi-asserted-by":"crossref","unstructured":"Oomenns, C. W. J., Ratingen, M. R. V., Janssen, J. D., Kok, J. J., and Hendricks, M. A. N., 1993, \u201cA Numerical-Experimental Method for a Mechanical Characterization of Biological Materials,\u201d J. Biomech., 26, pp. 617\u2013621.","DOI":"10.1016\/0021-9290(93)90024-9"},{"key":"2019100603505861800_r50","doi-asserted-by":"crossref","unstructured":"Novak, V. P., Yin, F. C. P., and Humphrey, J. D., 1994, \u201cRegional Mechanical Properties of Passive Myocardium,\u201d J. Biomech., 27, pp. 403\u2013412.","DOI":"10.1016\/0021-9290(94)90016-7"},{"key":"2019100603505861800_r51","doi-asserted-by":"crossref","unstructured":"Vorp, D. A., Rajagopal, K. R., Smolinski, P. J., and Borovetz, H. S., 1995, \u201cIdentification of Elastic Properties of Homogenious Orthotropic Vascular Segments in Distension,\u201d J. Biomech., 28, pp. 501\u2013512.","DOI":"10.1016\/0021-9290(94)00012-S"},{"key":"2019100603505861800_r52","unstructured":"Wang, J. L., Parnianpour, M., Shirazi-Adl, A., and Engin, A. E., 1996, \u201cDevelopment of the Viscoleastic Finite Element Model of Lumbar Motion Segment,\u201d ASME PD, 77, pp. 51\u201356."},{"key":"2019100603505861800_r53","unstructured":"Nagaraj, A., Ramani, K., Kane, B. J., Greene, R., Dove, E. L., Chandran, K. B., and McPherson, D. D., 1997, \u201cIn-Vivo Regional Assessment of Atherosclerotic Vascular Material Properties Using Three Dimensional Intravascular Ultrasound Reconstruction and Finite Element Analysis,\u201d ASME-BED, 35, pp. 463\u2013464."},{"key":"2019100603505861800_r54","doi-asserted-by":"crossref","unstructured":"Flynn, D. M., Peura, G. D., Grigg, P., and Hoffman, A. H., 1998, \u201cA Finite Element Based Method to Determine the Properties of Planar Soft Tissue,\u201d J. Biomech. Eng., 120, pp. 202\u2013210.","DOI":"10.1115\/1.2798303"},{"key":"2019100603505861800_r55","unstructured":"Steege, J. W., and Childress, D. S., 1988, \u201cFinite Element Modeling of the Below-Knee Socket and Limb: Phase II,\u201d Proc. Bioeng. Conf. (ASME-BED), pp. 121\u2013129."},{"key":"2019100603505861800_r56","unstructured":"Vannah, W. M., 1990, \u201cIndentor Tests and Finite Element Modeling of Bulk Muscular Soft Tissue In Vivo,\u201d Ph.D. Dissertation, Northwestern University, Evanston, IL."},{"key":"2019100603505861800_r57","unstructured":"Vetrano, S. L., and Silver-Thorn, M. B., 1997, \u201cAnalysis of Residual Limb Bulk Soft Tissue Behavior Using Nonlinear Finite Element Methods,\u201d Proc. 2nd Ann. Conf. Finite Element Methods Bioeng., MARC Analysis Research Corp., University of Minneapolis, pp. 29\u201336."},{"key":"2019100603505861800_r58","doi-asserted-by":"crossref","unstructured":"Tonuk, E., and Silver-Thorn, M. B., 2003, \u201cNonlinear Elastic Material Property Estimation of Lower Extremity Residual Limb Tissue,\u201d IEEE Trans. Neural Sys. Rehab. Eng., 11(1), pp. 43\u201353.","DOI":"10.1109\/TNSRE.2003.810436"},{"key":"2019100603505861800_r59","doi-asserted-by":"crossref","unstructured":"Pathak, A. P., Silver-Thorn, M. B., Thierfelder, C. A., and Prieto, T. E., 1998, \u201cA Rate-Controlled Indentor for In Vivo Analysis of Residual Limb Tissues,\u201d IEEE Trans. Rehabil. Eng., 6, pp. 12\u201320.","DOI":"10.1109\/86.662616"},{"key":"2019100603505861800_r60","doi-asserted-by":"crossref","unstructured":"Tonuk, E., and Silver-Thorn, M. B., 1999, \u201cNonlinear Viscoelastic Material Property Estimation for Lower Extremity Residual Limbs,\u201d Proc. 1st BMES EMBS Conference., Atlanta GA, 1, p. 645.","DOI":"10.1109\/IEMBS.1999.802723"},{"key":"2019100603505861800_r61","doi-asserted-by":"crossref","unstructured":"Simo, J. C. , 1987, \u201cOn a Fully Three-Dimensional Viscoelastic Damage Model: Formulation and Computational Aspects,\u201d Comput. Methods Appl. Mech. Eng., 60, pp. 153\u2013173.","DOI":"10.1016\/0045-7825(87)90107-1"},{"key":"2019100603505861800_r62","doi-asserted-by":"crossref","unstructured":"Gerhard, A. H., and Simo, J. C., 1996, \u201cA New Viscoelastic Constitutive Model for Continuous Media at Finite Thermomechanical Changes,\u201d Int. J. Solids Struct., 33, pp. 3019\u20133034.","DOI":"10.1016\/0020-7683(95)00263-4"},{"key":"2019100603505861800_r63","doi-asserted-by":"crossref","unstructured":"Sanders, J. E., and Daly, C. H., 1993, \u201cMeasurement of Stresses in Three Orthogonal Directions at the Residual Limb-Prosthetic Socket Interface,\u201d IEEE Trans. Rehabil. Eng., 1, pp. 79\u201385.","DOI":"10.1109\/86.242421"},{"key":"2019100603505861800_r64","unstructured":"Silver-Thorn, M. B., 1991, \u201cPrediction and Experimental Verification of Residual Limb\/Prosthetic Socket Interface Pressures for Below-Knee Amputees,\u201d Ph.D. Dissertation, Northwestern University, Evanston, IL."},{"key":"2019100603505861800_r65","doi-asserted-by":"crossref","unstructured":"Tonuk, E., and Silver-Thorn, M. B., 1999, \u201cEffect of Curvature on Lower Extremity Residual Limb Models,\u201d Proc. 1st BMES EMBS Conference., Atlanta GA, 1, p. 639.","DOI":"10.1109\/IEMBS.1999.802717"},{"key":"2019100603505861800_r66","unstructured":"Malvern, L. E., 1969, \u201cIntroduction to the Mechanics of a Continuous Medium,\u201d Prentice-Hall Inc., Englewood Cliffs, New Jersey, pp. 313\u2013319."},{"key":"2019100603505861800_r67","unstructured":"Lakes, R. S., 1998, \u201cViscoelastic Solids,\u201d CRC Press, Washington D. C., pp. 23\u201330."}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/126\/2\/289\/5524364\/289_1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/126\/2\/289\/5524364\/289_1.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,16]],"date-time":"2024-12-16T11:55:19Z","timestamp":1734350119000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/126\/2\/289\/464007\/Nonlinear-Viscoelastic-Material-Property"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,4,1]]},"references-count":67,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2004,4,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.1695575","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,4,1]]}}}