{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,23]],"date-time":"2026-04-23T05:20:05Z","timestamp":1776921605705,"version":"3.51.2"},"reference-count":24,"publisher":"ASME International","issue":"4","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2005,8,1]]},"abstract":"<jats:p>Quantification of knee motion under dynamic, in vivo loaded conditions is necessary to understand how knee kinematics influence joint injury, disease, and rehabilitation. Though recent studies have measured three-dimensional knee kinematics by matching geometric bone models to single-plane fluoroscopic images, factors limiting the accuracy of this approach have not been thoroughly investigated. This study used a three-step computational approach to evaluate theoretical accuracy limitations due to the shape matching process alone. First, cortical bone models of the femur, tibia\/fibula, and patella were created from CT data. Next, synthetic (i.e., computer generated) fluoroscopic images were created by ray tracing the bone models in known poses. Finally, an automated matching algorithm utilizing edge detection methods was developed to align flat-shaded bone models to the synthetic images. Accuracy of the recovered pose parameters was assessed in terms of measurement bias and precision. Under these ideal conditions where other sources of error were eliminated, tibiofemoral poses were within 2mm for sagittal plane translations and 1.5deg for all rotations while patellofemoral poses were within 2mm and 3deg. However, statistically significant bias was found in most relative pose parameters. Bias disappeared and precision improved by a factor of two when the synthetic images were regenerated using flat shading (i.e., sharp bone edges) instead of ray tracing (i.e., attenuated bone edges). Analysis of absolute pose parameter errors revealed that the automated matching algorithm systematically pushed the flat-shaded bone models too far into the image plane to match the attenuated edges of the synthetic ray-traced images. These results suggest that biased edge detection is the primary factor limiting the theoretical accuracy of this single-plane shape matching procedure.<\/jats:p>","DOI":"10.1115\/1.1933949","type":"journal-article","created":{"date-parts":[[2006,1,5]],"date-time":"2006-01-05T16:54:38Z","timestamp":1136480078000},"page":"692-699","update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":129,"title":["Theoretical Accuracy of Model-Based Shape Matching for Measuring Natural Knee Kinematics with Single-Plane Fluoroscopy"],"prefix":"10.1115","volume":"127","author":[{"given":"Benjamin J.","family":"Fregly","sequence":"first","affiliation":[{"name":"(352) 392-8157\n            (352) 392-7303"},{"name":"Department of Mechanical and Aerospace Engineering, Department of Biomedical Engineering, Department of Othopaedics and Rehabilitation, University of Florida, Gainesville, FL 32611"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haseeb A.","family":"Rahman","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Scott A.","family":"Banks","sequence":"additional","affiliation":[{"name":"Department of Mechanical and Aerospace Engineering, Department of Orthopaedics and Rehabilitation, University of Florida, Gainesville, FL 32611 and The Biomotion Foundation, West Palm Beach, FL 33480"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"33","published-online":{"date-parts":[[2005,1,27]]},"reference":[{"key":"2019100411151484800_c1","unstructured":"Centers for Disease Control and Prevention, 2003, \u201cTargeting Arthritis: The Nation\u2019s Leading Cause of Disability,\u201d National Center for Chronic Disease Prevention and Health Promotion, Atlanta, Georgia, http:\/\/www.cdc.gov\/nccdphp\/aag\/pdf\/aag\u0331arthritis2003.pdf."},{"key":"2019100411151484800_c2","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1016\/S0021-9290(97)00119-X","article-title":"In Vivo Knee Joint Loading and Kinematics Before and After ACL Transection in an Animal Model","volume":"31","author":"Hasler","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100411151484800_c3","unstructured":"Tashman, S., Anderst, W., and Kolowich, P., 1999, \u201cSeverity of OA Related to Magnitude of Dynamic Instability in ACL-Deficient Dogs,\u201d Transactions of the 46th Annual Meeting of the Orthopaedic Research Society, Orlando, FL, pp. 257."},{"key":"2019100411151484800_c4","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1016\/0167-9457(91)90047-2","article-title":"Three-Dimensional Analysis of Human Walking: Experimental Methods and Associated Artifacts","volume":"10","author":"Cappozzo","journal-title":"Hum. Mov. Sci.","ISSN":"https:\/\/id.crossref.org\/issn\/0167-9457","issn-type":"print"},{"key":"2019100411151484800_c5","doi-asserted-by":"publisher","first-page":"1165","DOI":"10.1109\/10.649988","article-title":"Surface Marker Cluster Design Criteria for 3-D Bone Movement Reconstruction","volume":"44","author":"Cappozzo","journal-title":"IEEE Trans. Biomed. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0018-9294","issn-type":"print"},{"key":"2019100411151484800_c6","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/S0167-9457(96)00053-X","article-title":"A Comparison of Lower-Extremity Skeletal Kinematics Measured using Skin- and Pin-Mounted Markers","volume":"16","author":"Fuller","journal-title":"Hum. Mov. Sci.","ISSN":"https:\/\/id.crossref.org\/issn\/0167-9457","issn-type":"print"},{"key":"2019100411151484800_c7","doi-asserted-by":"publisher","first-page":"977","DOI":"10.1016\/S0021-9290(98)00083-9","article-title":"Skin Movement Artifact Assessment and Compensation in the Estimation of Knee Joint Kinematics","volume":"31","author":"Lucchitti","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100411151484800_c8","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1016\/S0021-9290(98)00158-4","article-title":"Bone Position Estimation from Skin Marker Coordinates using Global Optimization with Joint Constraints","volume":"32","author":"Lu","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100411151484800_c9","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1115\/1.2834888","article-title":"A Point Cluster Method for In Vivo Motion Analysis: Applied to a Study of Knee Kinematics","volume":"120","author":"Andriacchi","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100411151484800_c10","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1016\/S0021-9290(00)00192-5","article-title":"Correcting for Deformation in Skin-Based Marker Systems","volume":"34","author":"Alexander","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100411151484800_c11","doi-asserted-by":"publisher","first-page":"638","DOI":"10.1109\/10.495283","article-title":"Accurate Measurement of Three-Dimensional Knee Replacement Kinematics using Single-Plane Fluoroscopy","volume":"43","author":"Banks","journal-title":"IEEE Trans. Biomed. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0018-9294","issn-type":"print"},{"key":"2019100411151484800_c12","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1016\/S0883-5403(97)90026-7","article-title":"In Vivo Kinematics of Cruciate-Retaining and Substituting Knee Arthroplasties","volume":"12","author":"Banks","journal-title":"J. Arthroplasty","ISSN":"https:\/\/id.crossref.org\/issn\/0883-5403","issn-type":"print"},{"key":"2019100411151484800_c13","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1016\/S0268-0033(98)00009-6","article-title":"Three-Dimensional Determination of Femoral-Tibial Contact Positions under In Vivo Conditions using Fluoroscopy","volume":"13","author":"Hoff","journal-title":"Clin. Biomech. (Los Angel. Calif.)","ISSN":"https:\/\/id.crossref.org\/issn\/0191-7870","issn-type":"print"},{"key":"2019100411151484800_c14","first-page":"9","article-title":"Interactive System for Kinematic Analysis of Artificial Joint Implants","volume":"35","author":"Sarojak","journal-title":"Biomed. Sci. Instrum.","ISSN":"https:\/\/id.crossref.org\/issn\/0067-8856","issn-type":"print"},{"key":"2019100411151484800_c15","doi-asserted-by":"publisher","first-page":"1561","DOI":"10.1109\/TMI.2003.820027","article-title":"A Robust Method for Registration of Three-Dimensional Knee Implant Models to Two-Dimensional Fluoroscopy Images","volume":"22","author":"Mahfouz","journal-title":"IEEE Trans. Med. Imaging","ISSN":"https:\/\/id.crossref.org\/issn\/0278-0062","issn-type":"print"},{"key":"2019100411151484800_c16","doi-asserted-by":"publisher","first-page":"514","DOI":"10.1109\/42.929617","article-title":"In Vivo Measurement of 3D Skeletal Kinematics from Sequences of Biplane Radiographs: Application to Knee Kinematics","volume":"20","author":"You","journal-title":"IEEE Trans. Med. Imaging","ISSN":"https:\/\/id.crossref.org\/issn\/0278-0062","issn-type":"print"},{"key":"2019100411151484800_c17","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1016\/S0021-9290(03)00157-X","article-title":"A Method to Estimate In Vivo Dynamic Articular Surface Interaction","volume":"36","author":"Anderst","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100411151484800_c18","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1115\/1.1559896","article-title":"In Vivo Measurement of Dynamic Joint Motion using High Speed Biplane Radiography and CT: Application to Canine ACL Deficiency","volume":"125","author":"Tashman","journal-title":"J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"key":"2019100411151484800_c19","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1007\/s00167-002-0330-y","article-title":"Weight-Bearing Knee Kinematics in Subjects with Two Types of Anterior Cruciate Ligament Reconstructions","volume":"11","author":"Kanisawa","journal-title":"Knee Surg. Sports Traumatol. Arthrosc","ISSN":"https:\/\/id.crossref.org\/issn\/0942-2056","issn-type":"print"},{"key":"2019100411151484800_c20","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1097\/01.blo.0000062384.79828.3b","article-title":"In Vivo Fluoroscopic Analysis of the Normal Human Knee","volume":"410","author":"Komistek","journal-title":"Clin. Orthop. Relat. Res.","ISSN":"https:\/\/id.crossref.org\/issn\/0009-921X","issn-type":"print"},{"key":"2019100411151484800_c21","first-page":"197","article-title":"In Vivo Determination of Knee Kinematics in Patients with a Hamstring or Patellar Tendon ACL Graft","volume":"16","author":"Mahfouz","journal-title":"Journal of Knee Surgery"},{"key":"2019100411151484800_c22","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1007\/BF02441745","article-title":"Use of Cardan Angles to Locate Rigid Bodies in Three-Dimensional Space","volume":"25","author":"Tupling","journal-title":"Med. Biol. Eng. Comput.","ISSN":"https:\/\/id.crossref.org\/issn\/0140-0118","issn-type":"print"},{"key":"2019100411151484800_c23","first-page":"873","article-title":"A New Model-Based RSA Method Validated using CAD Models and Models from Reversed Engineering","volume":"366","author":"Kaptein","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100411151484800_c24","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1016\/j.jbiomech.2004.02.013","article-title":"Computational Wear Prediction of a Total Knee Replacement from In Vivo Kinematics","volume":"38","author":"Fregly","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/127\/4\/692\/5769608\/692_1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/127\/4\/692\/5769608\/692_1.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,4]],"date-time":"2019-10-04T15:23:46Z","timestamp":1570202626000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/127\/4\/692\/450785\/Theoretical-Accuracy-of-ModelBased-Shape-Matching"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,1,27]]},"references-count":24,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2005,8,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.1933949","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,1,27]]}}}