{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T03:00:09Z","timestamp":1768705209522,"version":"3.49.0"},"reference-count":24,"publisher":"ASME International","issue":"4","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2006,8,1]]},"abstract":"<jats:p>Articulating cervical disk implants have been proposed as an alternative to disk fusion in the treatment of cervical disk disease. To examine the mechanical effect of articulating cervical disk implants (ACDI) versus simulated cervical disk fusion, a mechanical test device was constructed and cadaveric tests were carried out. While results show little effect on the pressures above and below the treatment level, the percent hysteretic behavior of the specimens trended to be higher for the ACDI, indicating that these implants retain more of the natural energy absorption capability of the cervical spine.<\/jats:p>","DOI":"10.1115\/1.2205373","type":"journal-article","created":{"date-parts":[[2006,6,30]],"date-time":"2006-06-30T13:17:08Z","timestamp":1151673428000},"page":"481-486","update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":12,"title":["Comparison of Cervical Disk Implants and Cervical Disk Fusion Treatments in Human Cadaveric Models"],"prefix":"10.1115","volume":"128","author":[{"given":"M. A.","family":"Davies","sequence":"first","affiliation":[{"name":"Mechanical Engineering & Engineering Science, University of North Carolina at Charlotte, University City Boulevard, Charlotte, NC 28223"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S. C.","family":"Bryant","sequence":"additional","affiliation":[{"name":"Mechanical Engineering & Engineering Science, University of North Carolina at Charlotte, University City Boulevard, Charlotte, NC 28223"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S. P.","family":"Larsen","sequence":"additional","affiliation":[{"name":"Mechanical Engineering & Engineering Science, University of North Carolina at Charlotte, University City Boulevard, Charlotte, NC 28223"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D. B.","family":"Murrey","sequence":"additional","affiliation":[{"name":"Charlotte Spine Center, Charlotte Orthopedic Research Institute, Randolph Rd., Charlotte, NC 28203"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D. S.","family":"Nussman","sequence":"additional","affiliation":[{"name":"Charlotte Spine Center, Charlotte Orthopedic Research Institute, Randolph Rd., Charlotte, NC 28203"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E. B.","family":"Laxer","sequence":"additional","affiliation":[{"name":"Charlotte Spine Center, Charlotte Orthopedic Research Institute, Randolph Rd., Charlotte, NC 28203"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"suffix":"III","given":"B. V.","family":"Darden","sequence":"additional","affiliation":[{"name":"Charlotte Spine Center, Charlotte Orthopedic Research Institute, Randolph Rd., Charlotte, NC 28203"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"33","published-online":{"date-parts":[[2006,1,10]]},"reference":[{"key":"2019100511461516500_c1","doi-asserted-by":"publisher","first-page":"1157","DOI":"10.1016\/0142-9612(96)84936-2","article-title":"The Artificial Disc: Theory, Design and Materials","volume":"17","author":"Bao","journal-title":"Biomaterials","ISSN":"https:\/\/id.crossref.org\/issn\/0142-9612","issn-type":"print"},{"key":"2019100511461516500_c2","unstructured":"Patil, A. A.\n          , \u201cArtificial Intervertebral Disc,\u201d U.S. Patent No. 4,309,777, January 12, 1982."},{"key":"2019100511461516500_c3","unstructured":"Salib, R. M., and Pettine, K. A., \u201cIntervertebral Disk Arthroplasty,\u201d U.S. Patent No. 5,258,031, November 2, 1993."},{"key":"2019100511461516500_c4","unstructured":"Weber, B. G.\n          , 1980, \u201cTotal Intervertebral Disc Prosthesis,\u201d West German Patent DE 3,023,353."},{"key":"2019100511461516500_c5","unstructured":"B\u00fcttner-Janz, K., Helisch, H. J., Schellnack, K., and Shumann, R., 1988, \u201cIntervertebral Disc Endoprosthesis,\u201d U.S. Patent 4,759,766."},{"key":"2019100511461516500_c6","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1007\/BF00268042","article-title":"Biomechanics of the SB Charit\u00e9 Lumbar Intervertebral Disc","volume":"13","author":"B\u00fcttner-Janz","journal-title":"Endoprosthesis Int Orthop (SICOT)"},{"issue":"4","key":"2019100511461516500_c7","first-page":"11","article-title":"A Brief Review of Disc Replacements","volume":"15","author":"Mendenhall","journal-title":"Orthopedic Network News"},{"key":"2019100511461516500_c8","unstructured":"12http:\/\/biomed.brown.edu\/Courses\/BI108\/BI108_2002_Groups\/discs\/Bryan.htm."},{"key":"2019100511461516500_c9","unstructured":"http:\/\/www.spine-health.com\/research\/trials\/prodisc_c\/prodisc_c01.html."},{"key":"2019100511461516500_c10","unstructured":"Murrey, D. B., Darden, B. V., Laxer, E. B., Rhyne, A. L., Milam, A., Haney, A. D., and Odum, S. M., 2005, \u201cEarly Results of a Randomized Controlled Clinical Trial Comparing Prodisc-C\u00ae and ACDF for Cervical Radiculopathy,\u201d Spine Arthroplasty Society, New York."},{"key":"2019100511461516500_c11","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.1097\/00007632-198810000-00013","article-title":"Biomechanical Evaluation of Spinal Fusion Devices: A Conceptual Framework","volume":"13","author":"Panjabi","journal-title":"Spine","ISSN":"https:\/\/id.crossref.org\/issn\/0362-2436","issn-type":"print"},{"key":"2019100511461516500_c12","first-page":"765","article-title":"A Continuous Pure Moment Loading Apparatus for Biomechanical Testing of Multi-Segment Spine Segments","volume":"22","author":"Lysack","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100511461516500_c13","doi-asserted-by":"crossref","first-page":"1153","DOI":"10.1097\/00007632-199011010-00013","article-title":"Intersegmental Spinal Flexibility With Lumbosacral Instrumentation. An In-Vitro Investigation","volume":"15","author":"Asazuma","journal-title":"Spine","ISSN":"https:\/\/id.crossref.org\/issn\/0362-2436","issn-type":"print"},{"key":"2019100511461516500_c14","doi-asserted-by":"crossref","first-page":"2097","DOI":"10.1097\/00007632-199510000-00005","article-title":"An Apparatus for Providing Pure Nonconstraining Moments to Spine Segments In Vitro","volume":"20","author":"Crawford","journal-title":"Spine","ISSN":"https:\/\/id.crossref.org\/issn\/0362-2436","issn-type":"print"},{"key":"2019100511461516500_c15","doi-asserted-by":"crossref","first-page":"2214","DOI":"10.1097\/00007632-200110150-00012","article-title":"Development of a System for In-Vitro Neck Muscle Force Replication With Whole Cervical Spine Specimens","volume":"26","author":"Panjabi","journal-title":"Spine","ISSN":"https:\/\/id.crossref.org\/issn\/0362-2436","issn-type":"print"},{"key":"2019100511461516500_c16","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/S0268-0033(98)00031-X","article-title":"Multiple Muscle Force Simulation in Axial Rotation of the Cervical Spine","volume":"14","author":"Bernhardt","journal-title":"Clin. Biomech. (Los Angel. Calif.)","ISSN":"https:\/\/id.crossref.org\/issn\/0191-7870","issn-type":"print"},{"issue":"4","key":"2019100511461516500_c17","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1097\/00024720-200308000-00002","article-title":"Biomechanical Testing of an Artificial Cervical Joint and an Anterior Cervical Plate","volume":"16","author":"DiAngelo","journal-title":"J. Spinal Disord.","ISSN":"https:\/\/id.crossref.org\/issn\/0895-0385","issn-type":"print"},{"key":"2019100511461516500_c18","doi-asserted-by":"crossref","first-page":"1559","DOI":"10.1016\/S0021-9290(00)00145-7","article-title":"In Vitro Axial Preload Application During Spine Flexibility Resting: Towards Reduced Apparatus-Related Artifacts","volume":"33","author":"Cripton","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100511461516500_c19","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/0268-0033(94)90021-3","article-title":"Passive Stiffness of the Human Neck in Flexion, Extension and Lateral Bending","volume":"9","author":"McGill","journal-title":"Clin. Biomech. (Los Angel. Calif.)","ISSN":"https:\/\/id.crossref.org\/issn\/0191-7870","issn-type":"print"},{"issue":"22","key":"2019100511461516500_c20","doi-asserted-by":"crossref","first-page":"2431","DOI":"10.1097\/00007632-200211150-00003","article-title":"Biomechanical Study on the Effect of Cervical Spine Fusion on Adjacent-Level Intradiscal Pressure and Segmental Motion","volume":"27","author":"Eck","journal-title":"Spine","ISSN":"https:\/\/id.crossref.org\/issn\/0362-2436","issn-type":"print"},{"key":"2019100511461516500_c21","first-page":"117","article-title":"Cervical Spine Stabilization: A Three-Dimensional, Biomechanical Evaluation of Rotational Stability, Strength and Failure Mechanisms","volume":"16","author":"Pelker","journal-title":"Spine","ISSN":"https:\/\/id.crossref.org\/issn\/0362-2436","issn-type":"print"},{"key":"2019100511461516500_c22","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1007\/s005860050045","article-title":"Testing Criteria for Spinal Implants: Recommendations for the Standardization of In-Vitro Stability Testing of Spinal Implants","volume":"7","author":"Wilke","journal-title":"Eur. Spine J.","ISSN":"https:\/\/id.crossref.org\/issn\/0940-6719","issn-type":"print"},{"issue":"4","key":"2019100511461516500_c23","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/S0021-9290(00)00205-0","article-title":"A Minimally Disruptive Technique for Measuring Intervertebral Disc Pressure In Vitro: Application to the Cervical Spine","volume":"34","author":"Cripton","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100511461516500_c24","doi-asserted-by":"crossref","first-page":"1559","DOI":"10.1016\/S0021-9290(00)00145-7","article-title":"In Vitro Axial Preload Application During Spine Flexibility Testing: Towards Reduced Apparatus-Related Artefacts","volume":"33","author":"Cripton","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/128\/4\/481\/5610543\/481_1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/128\/4\/481\/5610543\/481_1.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,5]],"date-time":"2019-10-05T15:46:25Z","timestamp":1570290385000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/128\/4\/481\/475078\/Comparison-of-Cervical-Disk-Implants-and-Cervical"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,1,10]]},"references-count":24,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2006,8,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.2205373","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,1,10]]}}}