{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T07:46:10Z","timestamp":1769154370887,"version":"3.49.0"},"reference-count":54,"publisher":"ASME International","issue":"1","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2007,2,1]]},"abstract":"<jats:p>Malalignment is the main cause of tibial component loosening. Implants that migrate rapidly in the first two post-operative years are likely to present aseptic loosening. It has been suggested that cancellous bone stresses can be correlated with tibial component migration. A recent study has shown that patient-specific finite element (FE) models have the power to predict the short-term behavior of tibial trays. The stresses generated within the implanted tibia are dependent on the kinematics of the joint; however, previous studies have ignored the kinematics and only applied static loads. Using explicit FE, it is possible to simultaneously predict the kinematics and stresses during a gait cycle. The aim of this study was to examine the cancellous bone strains during the stance phase of the gait cycle, for varying degrees of varus\/valgus eccentric loading using explicit FE. A patient-specific model of a proximal tibia was created from CT scan images, including heterogeneous bone properties. The proximal tibia was implanted with a commercial total knee replacement (TKR) model. The stance phase of gait was simulated and the applied loads and boundary conditions were based on those used for the Stanmore knee simulator. Eccentric loading was simulated. As well as examining the tibial bone strains (minimum and maximum principal strain), the kinematics of the bone-implant construct are also reported. The maximum anterior\u2013posterior displacements and internal\u2013external rotations were produced by the model with 20mm offset. The peak minimum and maximum principal strain values increased as the load was shifted laterally, reaching a maximum magnitude for \u221220mm offset. This suggests that when in varus, the load transferred to the bone is shifted medially, and as the bone supporting this load is stiffer, the resulting peak bone strains are lower than when the load is shifted laterally (valgus). For this particular patient, the TKR design analyzed produced the highest cancellous bone strains when in valgus. This study has provided an insight in the variations produced in bone strain distribution when the axial load is applied eccentrically. To the authors\u2019 knowledge, this is the first time that the bone strain distribution of a proximal implanted tibia has been examined, also accounting for the kinematics of the tibio\u2013femoral joint as part of the simulation. This approach gives greater insight into the overall performance of TKR.<\/jats:p>","DOI":"10.1115\/1.2401177","type":"journal-article","created":{"date-parts":[[2007,1,18]],"date-time":"2007-01-18T23:18:23Z","timestamp":1169162303000},"page":"1-11","update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":47,"title":["Effect of Varus\/Valgus Malalignment on Bone Strains in the Proximal Tibia After TKR: An Explicit Finite Element Study"],"prefix":"10.1115","volume":"129","author":[{"given":"A.","family":"Perillo-Marcone","sequence":"first","affiliation":[{"name":"Bioengineering Sciences Research Group, School of Engineering Sciences, University of Southampton, Southampton, Hampshire 5017 1BJ, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Taylor","sequence":"additional","affiliation":[{"name":"Bioengineering Sciences Research Group, School of Engineering Sciences, University of Southampton, Southampton, Hampshire 5017 1BJ, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"33","published-online":{"date-parts":[[2006,9,18]]},"reference":[{"key":"2019100412155468600_c1","first-page":"150","article-title":"Alignment Accuracy by Two Different Instrumentation Systems in Total Knee Arthroplasty","volume":"6","author":"Hilding","journal-title":"Am. J. Knee Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/0899-7403","issn-type":"print"},{"key":"2019100412155468600_c2","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/S0268-0033(01)00109-7","article-title":"The Effect of Malalignment on Stresses in Polyethylene Component of Total Knee Prostheses\u2014A Finite Element Analysis","volume":"17","author":"Liau","journal-title":"Clin. Biomech. (Bristol, Avon)","ISSN":"https:\/\/id.crossref.org\/issn\/0268-0033","issn-type":"print"},{"key":"2019100412155468600_c3","first-page":"178","article-title":"Alignment in Total Knee Arthroplasty. Correlated Biomechanical and Clinical Observations","volume":"173","author":"Bargren","journal-title":"Clin. Orthop. Relat. Res.","ISSN":"https:\/\/id.crossref.org\/issn\/0009-921X","issn-type":"print"},{"key":"2019100412155468600_c4","first-page":"135","article-title":"Effect of Knee Component Alignment on Tibial Load Distribution With Clinical Correlation","volume":"248","author":"Hsu","journal-title":"Clin. Orthop. Relat. Res.","ISSN":"https:\/\/id.crossref.org\/issn\/0009-921X","issn-type":"print"},{"issue":"1","key":"2019100412155468600_c5","doi-asserted-by":"crossref","first-page":"77","DOI":"10.2106\/00004623-197759010-00013","article-title":"Influence of Positioning of Prosthesis in Total Knee Replacement","volume":"59","author":"Lotke","journal-title":"J. Bone Jt. Surg., Am. Vol.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9355","issn-type":"print"},{"issue":"1","key":"2019100412155468600_c6","doi-asserted-by":"crossref","first-page":"60","DOI":"10.2106\/00004623-199401000-00008","article-title":"Radiolucency at the Bone-Cement Interface in Total Knee Replacement. The Effects of Bone-Surface Preparation and Cement Technique","volume":"76","author":"Ritter","journal-title":"J. Bone Jt. Surg., Am. Vol.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9355","issn-type":"print"},{"issue":"5","key":"2019100412155468600_c7","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1302\/0301-620X.73B5.1894655","article-title":"Coronal Alignment After Total Knee Replacement","volume":"73","author":"Jeffery","journal-title":"J. Bone Jt. Surg., Br. Vol.","ISSN":"https:\/\/id.crossref.org\/issn\/0301-620X","issn-type":"print"},{"issue":"4","key":"2019100412155468600_c8","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1302\/0301-620X.67B4.4030849","article-title":"Tibiofemoral Alignment and the Results of Knee Replacement","volume":"67","author":"Tew","journal-title":"J. Bone Jt. Surg., Br. Vol.","ISSN":"https:\/\/id.crossref.org\/issn\/0301-620X","issn-type":"print"},{"issue":"8","key":"2019100412155468600_c9","doi-asserted-by":"crossref","first-page":"1211","DOI":"10.2106\/00004623-198466080-00008","article-title":"Polycentric Total Knee Arthroplasty. A Ten-Year Follow-up Study","volume":"66","author":"Lewallen","journal-title":"J. Bone Jt. Surg., Am. Vol.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9355","issn-type":"print"},{"key":"2019100412155468600_c10","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/S0968-0160(99)00015-0","article-title":"Evaluation of Tibial Component Angles in 79 Consecutive Total Knee Arthroplasties","volume":"6","author":"Coull","journal-title":"The Knee","ISSN":"https:\/\/id.crossref.org\/issn\/0968-0160","issn-type":"print"},{"key":"2019100412155468600_c11","first-page":"252","article-title":"The Effect of a Stem on the Tibial Component of Knee Arthroplasty. A Roentgen Stereophotogrammetric Study of Uncemented Tibial Components in the Freeman\u2013Samuelson Knee Arthroplasty","volume":"72","author":"Albrektsson","journal-title":"J. Bone Jt. Surg., Br. Vol.","ISSN":"https:\/\/id.crossref.org\/issn\/0301-620X","issn-type":"print"},{"key":"2019100412155468600_c12","first-page":"233","article-title":"Proximally Cemented Versus Uncemented Freeman-Samuelson Knee Arthroplasty. A Prospective Randomised Study","volume":"74","author":"Albrektsson","journal-title":"J. Bone Jt. Surg., Br. Vol.","ISSN":"https:\/\/id.crossref.org\/issn\/0301-620X","issn-type":"print"},{"key":"2019100412155468600_c13","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/S0883-5403(06)80049-5","article-title":"A New Radiographic Method for Detection of Tibial Component Migration in Total Knee Arthroplasty","volume":"8","author":"Carlsson","journal-title":"J. Arthroplasty","ISSN":"https:\/\/id.crossref.org\/issn\/0883-5403","issn-type":"print"},{"key":"2019100412155468600_c14","doi-asserted-by":"crossref","first-page":"1665","DOI":"10.2106\/00004623-199811000-00014","article-title":"The Effect of Hydroxyapatite on the Micromotion of Total Knee Prostheses. A Prospective, Randomized, Double-Blind Study","volume":"80","author":"Nelissen","journal-title":"J. Bone Jt. Surg., Am. Vol.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9355","issn-type":"print"},{"key":"2019100412155468600_c15","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1302\/0301-620X.80B3.7937","article-title":"Hydroxyapatite Augmentation of the Porous Coating Improves Fixation of Tibial Components. A Randomised RSA Study in 116 Patients","volume":"80","author":"\u00d6nsten","journal-title":"J. Bone Jt. Surg., Br. Vol.","ISSN":"https:\/\/id.crossref.org\/issn\/0301-620X","issn-type":"print"},{"key":"2019100412155468600_c16","first-page":"377","article-title":"Roentgen Stereophotogrammetric Analysis as a Predictor of Mechanical Loosening of Knee Prostheses","volume":"77","author":"Ryd","journal-title":"J. Bone Jt. Surg., Br. Vol.","ISSN":"https:\/\/id.crossref.org\/issn\/0301-620X","issn-type":"print"},{"key":"2019100412155468600_c17","first-page":"239","article-title":"Early Migration of Prostheses Related to Long-Term Survivorship. Comparison of Tibial Components in Knee Replacement","volume":"74","author":"Grewal","journal-title":"J. Bone Jt. Surg., Br. Vol.","ISSN":"https:\/\/id.crossref.org\/issn\/0301-620X","issn-type":"print"},{"key":"2019100412155468600_c18","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1302\/0301-620X.82B2 .9461","article-title":"Estimation of the Migration of Tibial Components in Total Knee Arthroplasty","volume":"82","author":"Fukuoka","journal-title":"J. Bone Jt. Surg., Br. Vol.","ISSN":"https:\/\/id.crossref.org\/issn\/0301-620X","issn-type":"print"},{"key":"2019100412155468600_c19","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1302\/0301-620X.79B2.7461","article-title":"Fatigue Failure of Cancellous Bone: A Possible Cause of Implant Migration and Loosening","volume":"79","author":"Taylor","journal-title":"J. Bone Jt. Surg., Br. Vol.","ISSN":"https:\/\/id.crossref.org\/issn\/0301-620X","issn-type":"print"},{"key":"2019100412155468600_c20","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/0021-9290(83)90042-8","article-title":"An Analysis of Tibial Component Design in Total Knee Arthroplasty","volume":"16","author":"Murase","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100412155468600_c21","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1016\/0021-9290(86)90171-5","article-title":"Epiphyseal-Based Designs for Tibial Plateau Components\u2014II. Stress Analysis in the Sagittal Plane","volume":"19","author":"Beaupre","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100412155468600_c22","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1016\/0021-9290(86)90170-3","article-title":"Epiphyseal-Based Designs for Tibial Plateau Components\u2014I. Stress Analysis in the Frontal Plane","volume":"19","author":"Vasu","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100412155468600_c23","doi-asserted-by":"publisher","first-page":"1413","DOI":"10.1016\/0021-9290(92)90055-6","article-title":"A Finite Element Model for Evaluation of Tibial Prosthesis-Bone Interface in Total Knee Replacement","volume":"25","author":"Rakotomanana","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100412155468600_c24","doi-asserted-by":"crossref","first-page":"129","DOI":"10.2106\/00004623-198264010-00018","article-title":"A Comparative Evaluation of Tibial Component Designs of Total Knee Prostheses","volume":"64","author":"Lewis","journal-title":"J. Bone Jt. Surg., Am. Vol.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9355","issn-type":"print"},{"key":"2019100412155468600_c25","doi-asserted-by":"crossref","first-page":"1026","DOI":"10.2106\/00004623-198264070-00009","article-title":"Performance of the Tibial Component in Total Knee Replacement","volume":"64","author":"Bartel","journal-title":"J. Bone Jt. Surg., Am. Vol.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9355","issn-type":"print"},{"key":"2019100412155468600_c26","doi-asserted-by":"crossref","first-page":"1020","DOI":"10.1054\/arth.2000.17941","article-title":"The Importance of Tibial Alignment: Finite Element Analysis of Tibial Malalignment","volume":"15","author":"Perillo-Marcone","journal-title":"J. Arthroplasty","ISSN":"https:\/\/id.crossref.org\/issn\/0883-5403","issn-type":"print"},{"key":"2019100412155468600_c27","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1016\/S0021-9290(98)00022-0","article-title":"Finite Element Analysis of the Implanted Proximal Tibia: A Relationship Between the Initial Cancellous Bone Stresses and Implant Migration","volume":"31","author":"Taylor","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100412155468600_c28","doi-asserted-by":"publisher","first-page":"1205","DOI":"10.1016\/j.jbiomech.2003.12.004","article-title":"A Combined RSA and FE Study of the Implanted Proximal Tibia: Correlation of the Post-Operative Mechanical Environment With Implant Migration","volume":"37","author":"Perillo-Marcone","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100412155468600_c29","unstructured":"Perillo-Marcone, A.\n          , 2001, \u201cFinite Element Analysis of the Proximal Implanted Tibia in Relation to Implant Loosening,\u201d Ph.D. thesis, University of Southampton, Southampton, UK."},{"key":"2019100412155468600_c30","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/S0021-9290(01)00179-8","article-title":"Simulation of a Knee Joint Replacement During a Gait Cycle Using Explicit Finite Element Analysis","volume":"35","author":"Godest","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100412155468600_c31","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1097\/01.blo.0000079267.91782.58","article-title":"Explicit Finite Element Simulation of Eccentric Loading in Total Knee Replacement","volume":"414","author":"Taylor","journal-title":"Clin. Orthop. Relat. Res.","ISSN":"https:\/\/id.crossref.org\/issn\/0009-921X","issn-type":"print"},{"key":"2019100412155468600_c32","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1016\/S1350-4533(98)00081-2","article-title":"Material Properties Assignment to Finite Element Models of Bone Structures: A New Method","volume":"20","author":"Zannoni","journal-title":"Med. Eng. Phys.","ISSN":"https:\/\/id.crossref.org\/issn\/1350-4533","issn-type":"print"},{"key":"2019100412155468600_c33","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1002\/jor.1100090315","article-title":"Estimation of Mechanical Properties of Cortical Bone by Computed Tomography","volume":"9","author":"Snyder","journal-title":"J. Orthop. Res.","ISSN":"https:\/\/id.crossref.org\/issn\/0736-0266","issn-type":"print"},{"key":"2019100412155468600_c34","doi-asserted-by":"publisher","first-page":"895","DOI":"10.1016\/0021-9290(89)90073-0","article-title":"Anatomical Variation of Orthotropic Elastic Moduli of the Proximal Human Tibia","volume":"22","author":"Ashman","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100412155468600_c35","doi-asserted-by":"crossref","first-page":"954","DOI":"10.2106\/00004623-197759070-00021","article-title":"The Compressive Behavior of Bone as a Two-Phase Porous Structure","volume":"59","author":"Carter","journal-title":"J. Bone Jt. Surg., Am. Vol.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9355","issn-type":"print"},{"key":"2019100412155468600_c36","doi-asserted-by":"publisher","first-page":"1167","DOI":"10.1016\/0021-9290(90)90009-R","article-title":"Three-Axial Strain Controlled Testing Applied to Bone Specimens From the Proximal Tibial Epiphysis","volume":"23","author":"Linde","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100412155468600_c37","doi-asserted-by":"publisher","first-page":"803","DOI":"10.1016\/0021-9290(91)90305-7","article-title":"Mechanical Properties of Trabecular Bone. Dependency on Strain Rate","volume":"24","author":"Linde","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100412155468600_c38","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1080\/1025584031000064470","article-title":"Assessment of the Effect of Mesh Density on the Material Property Discretisation Within QCT Based FE Models: A Practical Example Using the Implanted Proximal Tibia","volume":"6","author":"Perillo-Marcone","journal-title":"Comput. Methods Biomech. Biomed. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/1025-5842","issn-type":"print"},{"key":"2019100412155468600_c39","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1016\/S1350-4533(98)00010-1","article-title":"Three-Dimensional Dynamic Behaviour of the Human Knee Joint Under Impact Loading","volume":"20","author":"Abdel-Rahman","journal-title":"Med. Eng. Phys.","ISSN":"https:\/\/id.crossref.org\/issn\/1350-4533","issn-type":"print"},{"key":"2019100412155468600_c40","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1115\/1.2894883","article-title":"Ligament-Bone Interaction in a Three-Dimensional Model of the Knee","volume":"113","author":"Blankevoort","journal-title":"J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"key":"2019100412155468600_c41","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1115\/1.2894090","article-title":"Recruitment of Knee Joint Ligaments","volume":"113","author":"Blankevoort","journal-title":"J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"key":"2019100412155468600_c42","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1016\/0021-9290(74)90010-4","article-title":"Variations in Strength and Structure of Cancellous Bone at the Knee","volume":"7","author":"Behrens","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100412155468600_c43","doi-asserted-by":"crossref","first-page":"11","DOI":"10.3109\/17453677608998966","article-title":"Mechanical Properties of Dried Defatted Spongy Bone","volume":"47","author":"Lindahl","journal-title":"Acta Orthop. Scand.","ISSN":"https:\/\/id.crossref.org\/issn\/0001-6470","issn-type":"print"},{"key":"2019100412155468600_c44","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1115\/1.3138303","article-title":"Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis","volume":"104","author":"Williams","journal-title":"J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"key":"2019100412155468600_c45","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1002\/jor.1100030409","article-title":"Trabecular Bone Strength Patterns at the Proximal Tibial Epiphysis","volume":"3","author":"Hvid","journal-title":"J. Orthop. Res.","ISSN":"https:\/\/id.crossref.org\/issn\/0736-0266","issn-type":"print"},{"key":"2019100412155468600_c46","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1146\/annurev.bioeng.3.1.307","article-title":"Biomechanics of Trabecular Bone","volume":"3","author":"Keaveny","journal-title":"Annu. Rev. Biomed. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/1523-9829","issn-type":"print"},{"key":"2019100412155468600_c47","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1115\/1.2798339","article-title":"A Cellular Solid Criterion for Predicting the Axial-Shear Failure Properties of Bovine Trabecular Bone","volume":"121","author":"Fenech","journal-title":"J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"key":"2019100412155468600_c48","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1016\/S0021-9290(01)00011-2","article-title":"Dependence of Yield Strain of Human Trabecular Bone on Anatomic Site","volume":"34","author":"Morgan","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100412155468600_c49","doi-asserted-by":"publisher","first-page":"763","DOI":"10.1016\/0021-9290(95)90059-4","article-title":"Is Yield Strain in Cancellous Bone Isotropic?","volume":"28","author":"Turner","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100412155468600_c50","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1002\/jor.1100170418","article-title":"Uniaxial Yield Strains for Bovine Trabecular Bone are Isotropic and Asymmetric","volume":"17","author":"Chang","journal-title":"J. Orthop. Res.","ISSN":"https:\/\/id.crossref.org\/issn\/0736-0266","issn-type":"print"},{"key":"2019100412155468600_c51","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/S0021-9290(96)00118-2","article-title":"A Knee Simulating Machine for Performance Evaluation of Total Knee Replacements","volume":"30","author":"Walker","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100412155468600_c52","first-page":"670","article-title":"Influence of Simulating the Collateral Ligaments When Modelling a Total Knee Replacement","volume-title":"Proceedings International Congress on Computational Bioengineering","author":"Tan"},{"key":"2019100412155468600_c53","unstructured":"Tan, K.\n          , 2004, \u201cAssessing the Performance Envelope of Total Knee Replacements\u2014An Explicit Finite Element Study,\u201d Ph.D. thesis, University of Southampton, Southampton, UK."},{"key":"2019100412155468600_c54","doi-asserted-by":"publisher","first-page":"1143","DOI":"10.1016\/0021-9290(91)90006-9","article-title":"Tensile and Compressive Properties of Cancellous Bone","volume":"24","author":"R\u00f8hl","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/129\/1\/1\/5770162\/1_1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/129\/1\/1\/5770162\/1_1.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,4]],"date-time":"2019-10-04T16:16:05Z","timestamp":1570205765000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/129\/1\/1\/445062\/Effect-of-VarusValgus-Malalignment-on-Bone-Strains"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,9,18]]},"references-count":54,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2007,2,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.2401177","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,9,18]]}}}