{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T08:40:01Z","timestamp":1789807201068,"version":"4.0.1"},"reference-count":34,"publisher":"ASME International","issue":"6","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2008,12,1]]},"abstract":"<jats:p>Wearable hip protectors represent a promising strategy for preventing hip fractures. However, there is lack of agreement on biomechanical testing standards and subsequent uncertainty about the ability of hip protectors to attenuate impact force during a fall. To address this issue, we designed a fall impact simulator that incorporated a \u201cbiofidelic\u201d surrogate pelvis, which matched the surface geometry and soft tissue stiffness measured in elderly women (n=15). We then used this system to measure the attenuation in peak femoral neck force provided by two commercially available soft shell protectors (Safehip Soft and Hipsaver) and one rigid shell protector (Safehip Classic). Finally, we examined how the force attenuation provided by each protector was influenced by systematic changes in fall severity (impact velocity), body size (pelvis size), and soft tissue stiffness. With the biofidelic pelvis, the force attenuation averaged over all impact velocities was 27% for Safehip Soft, 17% for Safehip Classic, and 19% for Hipsaver. However, the rank order of hip protectors (and especially the performance of Safehip Classic) varied with the test conditions. Safehip Classic attenuated force by 33% during a low velocity (1m\u2215s) fall, but only by 8% for a high velocity (4m\u2215s) fall. In the latter condition, improved attenuation was provided by the soft shell hip protectors (19% by Safehip Soft and 21% by Hipsaver). As soft tissue stiffness increased from softest to most rigid, the attenuation provided by Safehip Classic increased 2.9-fold (from 26% to 76%), while Safehip Soft increased 1.7-fold (from 36% to 60%) and Hipsaver increased 1.1-fold (from 36% to 38%). As pelvis size decreased from largest to smallest, the attenuation provided by Safehip Classic increased 8-fold, but for a high velocity fall and moderate tissue stiffness, never exceeded that provided by Safehip Soft and Hipsaver. Our results indicate that, under biofidelic testing conditions, the soft shell hip protectors we examined generally provided greater force attenuation (averaging up to 27%) than the hard shell protector. Measured values of force attenuation were highly sensitive to variations in impact velocity, pelvic size, and pelvic soft tissue stiffness. This indicates the need to develop international testing standards to guide market approval, the selection of protectors for clinical trials, and the design of improved hip protectors.<\/jats:p>","DOI":"10.1115\/1.2979867","type":"journal-article","created":{"date-parts":[[2008,11,11]],"date-time":"2008-11-11T23:25:46Z","timestamp":1226445946000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":66,"title":["The Force Attenuation Provided by Hip Protectors Depends on Impact Velocity, Pelvic Size, and Soft Tissue Stiffness"],"prefix":"10.1115","volume":"130","author":[{"given":"Andrew C.","family":"Laing","sequence":"first","affiliation":[{"name":"Faculty of Applied Sciences, Injury Prevention and Mobility Laboratory, School of Kinesiology, Simon Fraser University, 8888 University Drive, Burnaby, BC, V5A 1S6, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen N.","family":"Robinovitch","sequence":"additional","affiliation":[{"name":"Faculty of Applied Sciences, Injury Prevention and Mobility Laboratory, School of Kinesiology, and School of Engineering Science, Simon Fraser University, 8888 University Drive, Burnaby, BC, V5A 1S6, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"33","published-online":{"date-parts":[[2008,10,9]]},"reference":[{"issue":"10","key":"2019100512410770300_c1","first-page":"1357","article-title":"Current and Projected Rates of Hip Fracture in Canada","volume":"157","author":"Papadimitropoulos","journal-title":"CMAJ","ISSN":"https:\/\/id.crossref.org\/issn\/0820-3946","issn-type":"print"},{"issue":"5","key":"2019100512410770300_c2","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1111\/j.1532-5415.2004.52203.x","article-title":"Effect of Hip Fracture on Mortality in Elderly Women: The EPIDOS Prospective Study","volume":"52","author":"Empana","journal-title":"J. Am. Geriatr. Soc.","ISSN":"https:\/\/id.crossref.org\/issn\/0002-8614","issn-type":"print"},{"issue":"3","key":"2019100512410770300_c3","doi-asserted-by":"crossref","first-page":"398","DOI":"10.2105\/AJPH.87.3.398","article-title":"The Effect of Hip Fracture on Mortality, Hospitalization, and Functional Status: A Prospective Study","volume":"87","author":"Wolinsky","journal-title":"Am. J. Public Health","ISSN":"https:\/\/id.crossref.org\/issn\/0090-0036","issn-type":"print"},{"issue":"2","key":"2019100512410770300_c4","first-page":"105","article-title":"The Impact and Consequences of Hip Fracture in Ontario","volume":"39","author":"Jaglal","journal-title":"Can. J. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/0008-428X","issn-type":"print"},{"issue":"4","key":"2019100512410770300_c5","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1007\/s001980170116","article-title":"Economic Implications of Hip Fracture: Health Service Use, Institutional Care and Cost in Canada","volume":"12","author":"Wiktorowicz","journal-title":"Osteoporosis Int.","ISSN":"https:\/\/id.crossref.org\/issn\/0937-941X","issn-type":"print"},{"issue":"12","key":"2019100512410770300_c6","doi-asserted-by":"crossref","first-page":"1461","DOI":"10.1007\/s00198-005-1932-2","article-title":"Do Hip Protectors Decrease the Risk of Hip Fracture in Institutional and Community-Dwelling Elderly? A Systematic Review and Meta-Analysis of Randomized Controlled Trials","volume":"16","author":"Sawka","journal-title":"Osteoporosis Int.","ISSN":"https:\/\/id.crossref.org\/issn\/0937-941X","issn-type":"print"},{"issue":"7541","key":"2019100512410770300_c7","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1136\/bmj.38753.375324.7C","article-title":"Effectiveness of Hip Protectors for Preventing Hip Fractures in Elderly People: Systematic Review","volume":"332","author":"Parker","journal-title":"BMJ","ISSN":"https:\/\/id.crossref.org\/issn\/0959-8138","issn-type":"print"},{"issue":"4","key":"2019100512410770300_c8","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1001\/jama.298.4.413","article-title":"Efficacy of a Hip Protector to Prevent Hip Fracture in Nursing Home Residents: The HIP PRO Randomized Controlled Trial","volume":"298","author":"Kiel","journal-title":"JAMA, J. Am. Med. Assoc.","ISSN":"https:\/\/id.crossref.org\/issn\/0098-7484","issn-type":"print"},{"issue":"21","key":"2019100512410770300_c9","doi-asserted-by":"crossref","first-page":"1506","DOI":"10.1056\/NEJM200011233432101","article-title":"Prevention of Hip Fracture in Elderly People With Use of a Hip Protector","volume":"343","author":"Kannus","journal-title":"N. Engl. J. Med.","ISSN":"https:\/\/id.crossref.org\/issn\/0028-4793","issn-type":"print"},{"issue":"6","key":"2019100512410770300_c10","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1016\/j.medengphy.2005.02.001","article-title":"Anatomical Hip Model for the Mechanical Testing of Hip Protectors","volume":"27","author":"Derler","journal-title":"Med. Eng. Phys.","ISSN":"https:\/\/id.crossref.org\/issn\/1350-4533","issn-type":"print"},{"issue":"2","key":"2019100512410770300_c11","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/S8756-3282(99)00154-4","article-title":"Comparison of Force Attenuation Properties of Four Different Hip Protectors Under Simulated Falling Conditions in the Elderly: An In Vitro Biomechanical Study","volume":"25","author":"Kannus","journal-title":"Bone"},{"issue":"4","key":"2019100512410770300_c12","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1243\/PIME_PROC_1996_210_422_02","article-title":"The Biomechanics of Hip Protectors","volume":"210","author":"Mills","journal-title":"Proc. Inst. Mech. Eng., Part H: J. Eng. Med.","ISSN":"https:\/\/id.crossref.org\/issn\/0954-4119","issn-type":"print"},{"issue":"4","key":"2019100512410770300_c13","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1115\/1.2794200","article-title":"Energy-Shunting Hip Padding System Attenuates Femoral Impact Force in a Simulated Fall","volume":"117","author":"Robinovitch","journal-title":"ASME J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"issue":"2","key":"2019100512410770300_c14","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1016\/j.bone.2006.01.156","article-title":"Biomechanical Comparison of Hard and Soft Hip Protectors, and the Influence of Soft Tissue","volume":"39","author":"van Schoor","journal-title":"Bone"},{"issue":"3","key":"2019100512410770300_c15","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1016\/S0924-0136(02)00200-5","article-title":"Mechanical Testing of Hip Protectors","volume":"124","author":"Nabhani","journal-title":"J. Mater. Process. Technol.","ISSN":"https:\/\/id.crossref.org\/issn\/0924-0136","issn-type":"print"},{"issue":"39","key":"2019100512410770300_c16","doi-asserted-by":"crossref","first-page":"33","DOI":"10.7748\/ns2004.06.18.39.33.c3625","article-title":"Assessing the Safety and Effectiveness of Hip Protectors","volume":"18","author":"Minns","journal-title":"Nurs. Stand","ISSN":"https:\/\/id.crossref.org\/issn\/0029-6570","issn-type":"print"},{"issue":"3","key":"2019100512410770300_c17","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1007\/BF02684190","article-title":"Distribution of Contact Force During Impact to the Hip","volume":"25","author":"Robinovitch","journal-title":"Ann. Biomed. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0090-6964","issn-type":"print"},{"issue":"3","key":"2019100512410770300_c18","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1115\/1.2796083","article-title":"Predicting the Impact Response of a Nonlinear Single-Degree-of-Freedom Shock-Absorbing System From the Measured Step Response","volume":"119","author":"Robinovitch","journal-title":"ASME J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"issue":"12","key":"2019100512410770300_c19","doi-asserted-by":"crossref","first-page":"2612","DOI":"10.1016\/j.jbiomech.2007.01.019","article-title":"Reducing Hip Fracture Risk During Sideways Falls: Evidence in Young Adults of the Protective Effects of Impact to the Hands and Stepping","volume":"40","author":"Feldman","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"issue":"7","key":"2019100512410770300_c20","doi-asserted-by":"crossref","first-page":"1067","DOI":"10.1007\/s00198-008-0571-9","article-title":"Effect of Soft Shell Hip Protectors on Pressure Distribution to the Hip During Sideways Falls","volume":"19","author":"Laing","journal-title":"Osteoporosis Int.","ISSN":"https:\/\/id.crossref.org\/issn\/0937-941X","issn-type":"print"},{"key":"2019100512410770300_c21","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1097\/00003086-200205000-00023","article-title":"Force Reduction by an External Hip Protector on the Human Hip After Falls","volume":"398","author":"Wiener","journal-title":"Clin. Orthop. Relat. Res.","ISSN":"https:\/\/id.crossref.org\/issn\/0009-921X","issn-type":"print"},{"issue":"15","key":"2019100512410770300_c22","doi-asserted-by":"crossref","first-page":"1957","DOI":"10.1001\/jama.289.15.1957","article-title":"Prevention of Hip Fractures by External Hip Protectors: A Randomized Controlled Trial","volume":"289","author":"van Schoor","journal-title":"JAMA, J. Am. Med. Assoc.","ISSN":"https:\/\/id.crossref.org\/issn\/0098-7484","issn-type":"print"},{"issue":"6","key":"2019100512410770300_c23","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1093\/ageing\/30.6.477","article-title":"Hip Protectors in Aged-Care Facilities: A Randomized Trial of Use by Individual Higher-Risk Residents","volume":"30","author":"Cameron","journal-title":"Age Ageing","ISSN":"https:\/\/id.crossref.org\/issn\/0002-0729","issn-type":"print"},{"key":"2019100512410770300_c24","first-page":"403","volume-title":"Polymer Foams Handbook: Engineering and Biomechanics Applications and Design Guide","author":"Mills"},{"key":"2019100512410770300_c25","first-page":"1","article-title":"Biomechanical Response and Injury Tolerance of the Pelvis in Twelve Sled Side Impacts","volume-title":"Proceedings of the 34th Stapp Car Crash Conference","author":"Cavanaugh"},{"issue":"2","key":"2019100512410770300_c26","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1007\/s10439-005-8984-5","article-title":"Effects of Trochanteric Soft Tissues and Bone Density on Fracture of the Female Pelvis in Experimental Side Impacts","volume":"33","author":"Etheridge","journal-title":"Ann. Biomed. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0090-6964","issn-type":"print"},{"issue":"4","key":"2019100512410770300_c27","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1007\/s002239900242","article-title":"Impact Experiments of an External Hip Protector in Young Volunteers","volume":"60","author":"Parkkari","journal-title":"Calcif. Tissue Int.","ISSN":"https:\/\/id.crossref.org\/issn\/0171-967X","issn-type":"print"},{"issue":"7","key":"2019100512410770300_c28","doi-asserted-by":"crossref","first-page":"1405","DOI":"10.1002\/jor.20172","article-title":"Effect of Compliant Flooring on Impact Force During Falls on the Hip","volume":"24","author":"Laing","journal-title":"J. Orthop. Res.","ISSN":"https:\/\/id.crossref.org\/issn\/0736-0266","issn-type":"print"},{"issue":"7","key":"2019100512410770300_c29","doi-asserted-by":"publisher","first-page":"863","DOI":"10.1016\/S0021-9290(00)00025-7","article-title":"Impact Severity in Self-Initiated Sits and Falls Associates With Center-of-Gravity Excursion During Descent","volume":"33","author":"Robinovitch","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"issue":"6","key":"2019100512410770300_c30","doi-asserted-by":"publisher","first-page":"956","DOI":"10.1002\/jor.1100130621","article-title":"Force Attenuation in Trochanteric Soft Tissues During Impact From a Fall","volume":"13","author":"Robinovitch","journal-title":"J. Orthop. Res.","ISSN":"https:\/\/id.crossref.org\/issn\/0736-0266","issn-type":"print"},{"issue":"1","key":"2019100512410770300_c31","first-page":"91","article-title":"Protection Against Hip Fractures by Energy Absorption","volume":"39","author":"Lauritzen","journal-title":"Dan. Med. Bull.","ISSN":"https:\/\/id.crossref.org\/issn\/0907-8916","issn-type":"print"},{"issue":"3","key":"2019100512410770300_c32","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1359\/JBMR.0301247","article-title":"Reproducibility and Side Differences of Mechanical Tests for Determining the Structural Strength of the Proximal Femur","volume":"19","author":"Eckstein","journal-title":"J. Bone Miner. Res.","ISSN":"https:\/\/id.crossref.org\/issn\/0884-0431","issn-type":"print"},{"issue":"6","key":"2019100512410770300_c33","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1359\/jbmr.070309","article-title":"Contribution of Trochanteric Soft Tissues to Fall Force Estimates, the Factor of Risk, and Prediction of Hip Fracture Risk","volume":"22","author":"Bouxsein","journal-title":"J. Bone Miner. Res.","ISSN":"https:\/\/id.crossref.org\/issn\/0884-0431","issn-type":"print"},{"issue":"9391","key":"2019100512410770300_c34","doi-asserted-by":"crossref","first-page":"1168","DOI":"10.1016\/S0140-6736(03)14554-0","article-title":"Hip Protectors Need an Evidence Base","volume":"362","author":"Kannus","journal-title":"Lancet","ISSN":"https:\/\/id.crossref.org\/issn\/0140-6736","issn-type":"print"}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.2979867\/5684028\/061005_1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.2979867\/5684028\/061005_1.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,5]],"date-time":"2019-10-05T16:41:15Z","timestamp":1570293675000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/doi\/10.1115\/1.2979867\/456030\/The-Force-Attenuation-Provided-by-Hip-Protectors"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,10,9]]},"references-count":34,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2008,12,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.2979867","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,10,9]]},"article-number":"061005"}}