{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T08:34:22Z","timestamp":1769157262438,"version":"3.49.0"},"reference-count":58,"publisher":"ASME International","issue":"3","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2010,3,1]]},"abstract":"<jats:p>Numerical simulations are performed to investigate the flow within the end-to-side proximal anastomosis of a pulsatile pediatric ventricular assist device (PVAD) to an aorta. The anastomotic model is constructed from a patient-specific pediatric aorta. The three great vessels originating from the aortic arch\u2014 brachiocephalic (innominate), left common carotid, and left subclavian arteries\u2014are included. An implicit large eddy simulation method based on a finite volume approach is used to study the resulting turbulent flow. A resistance boundary condition is applied at each branch outlet to study flow splitting. The PVAD anastomosis is found to alter the aortic flow dramatically. More flow is diverted into the great vessels with the PVAD support. Turbulence is found in the jet impingement area at peak systole for 100% bypass, and a maximum principal normal Reynolds stress of 7081\u2002dyn\/cm2 is estimated based on ten flow cycles. This may be high enough to cause hemolysis and platelet activation. Regions prone to intimal hyperplasia are identified by combining the time-averaged wall shear stress and oscillatory shear index. These regions are found to vary, depending on the percentage of the flow bypass.<\/jats:p>","DOI":"10.1115\/1.4000872","type":"journal-article","created":{"date-parts":[[2010,5,11]],"date-time":"2010-05-11T22:46:59Z","timestamp":1273618019000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":12,"title":["Hemodynamics of an End-to-Side Anastomotic Graft for a Pulsatile Pediatric Ventricular Assist Device"],"prefix":"10.1115","volume":"132","author":[{"given":"Ning","family":"Yang","sequence":"first","affiliation":[{"name":"Department of Bioengineering, Pennsylvania State University, University Park, PA 16802"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Steven","family":"Deutsch","sequence":"additional","affiliation":[{"name":"Department of Bioengineering, Pennsylvania State University, University Park, PA 16802; Applied Research Laboratory, Pennsylvania State University, University Park, PA 16802"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eric G.","family":"Paterson","sequence":"additional","affiliation":[{"name":"Applied Research Laboratory, Pennsylvania State University, University Park, PA 16802; Department of Mechanical Engineering, Pennsylvania State University, University Park, PA 16802"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keefe B.","family":"Manning","sequence":"additional","affiliation":[{"name":"Department of Bioengineering, Pennsylvania State University, University Park, PA 16802"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"33","published-online":{"date-parts":[[2010,2,17]]},"reference":[{"key":"2019100513540728500_c1","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/0021-9290(95)00028-3","article-title":"Compliance and Diameter Mismatch Affect the Wall Shear Rate Distribution Near an End-to-End Anastomosis","volume":"29","author":"Weston","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100513540728500_c2","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1106\/NA5T-J57A-JTDD-FD04","article-title":"The Mechanical Behavior of Vascular Grafts: A Review","volume":"15","author":"Salacinski","journal-title":"J. Biomater. Appl.","ISSN":"https:\/\/id.crossref.org\/issn\/0885-3282","issn-type":"print"},{"key":"2019100513540728500_c3","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1114\/1.1481052","article-title":"A Numerical Study of Blood Flow in Coronary Artery Bypass Graft Side-to-Side Anastomoses","volume":"30","author":"Bonert","journal-title":"Ann. Biomed. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0090-6964","issn-type":"print"},{"key":"2019100513540728500_c4","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1146\/annurev.fluid.40.111406.102119","article-title":"Blood Flow in End-to-Side Anastomosis","volume":"40","author":"Loth","journal-title":"Annu. Rev. Fluid Mech.","ISSN":"https:\/\/id.crossref.org\/issn\/0066-4189","issn-type":"print"},{"key":"2019100513540728500_c5","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1146\/annurev.fluid.29.1.399","article-title":"Blood Flow in Arteries","volume":"29","author":"Ku","journal-title":"Annu. Rev. Fluid Mech.","ISSN":"https:\/\/id.crossref.org\/issn\/0066-4189","issn-type":"print"},{"key":"2019100513540728500_c6","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1115\/1.1389461","article-title":"Intimal Hyperplasia and Wall Shear in Arterial Bypass Graft Distal Anastomoses: An In Vivo Model Study","volume":"123","author":"Keynton","journal-title":"ASME J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"key":"2019100513540728500_c7","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1115\/1.1428554","article-title":"Relative Contribution of Wall Shear Stress and Injury in Experimental Intimal Thickening at PTFE End-to-Side Arterial Anastomoses","volume":"124","author":"Loth","journal-title":"ASME J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"key":"2019100513540728500_c8","doi-asserted-by":"crossref","first-page":"1254","DOI":"10.1161\/01.ATV.12.11.1254","article-title":"Vascular Endothelium Responds to Fluid Shear Stress Gradients","volume":"12","author":"DePaola","journal-title":"Arterioscler. Thromb.","ISSN":"https:\/\/id.crossref.org\/issn\/1049-8834","issn-type":"print"},{"issue":"3","key":"2019100513540728500_c9","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1161\/01.ATV.5.3.293","article-title":"Pulsatile Flow and Atherosclerosis in the Human Carotid Bifurcation. Positive Correlation between Plaque Location and Low Oscillating Shear Stress","volume":"5","author":"Ku","journal-title":"Arteriosclerosis (Dallas)","ISSN":"https:\/\/id.crossref.org\/issn\/0276-5047","issn-type":"print"},{"key":"2019100513540728500_c10","doi-asserted-by":"publisher","first-page":"609","DOI":"10.1016\/S0021-9290(98)00059-1","article-title":"Flow Waveform Effects on End-to-Side Anastomotic Flow Patterns","volume":"31","author":"Ross Ethier","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100513540728500_c11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1017\/S0022112099008022","article-title":"Steady Flow Separation Patterns in a 45 Degree Junction","volume":"411","author":"Ross Ethier","journal-title":"J. Fluid Mech.","ISSN":"https:\/\/id.crossref.org\/issn\/0022-1120","issn-type":"print"},{"key":"2019100513540728500_c12","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1115\/1.429630","article-title":"The Influence of Out-of-Plane Geometry on the Flow Within a Distal End-to-Side Anastomosis","volume":"122","author":"Sherwin","journal-title":"ASME J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"issue":"9","key":"2019100513540728500_c13","doi-asserted-by":"publisher","first-page":"1225","DOI":"10.1016\/S0021-9290(02)00072-6","article-title":"The Influence of Out-of-Plane Geometry on Pulsatile Flow Within a Distal End-to-Side Anastomosis","volume":"35","author":"Papaharilaou","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100513540728500_c14","first-page":"519","article-title":"Flow Phenomena in Compliant and Noncompliant Arteriovenous Grafts","volume":"34","author":"Shu","journal-title":"ASAIO Trans.","ISSN":"https:\/\/id.crossref.org\/issn\/0889-7190","issn-type":"print"},{"key":"2019100513540728500_c15","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1016\/j.jbiomech.2006.03.024","article-title":"Importance of Flow Division on Transition to Turbulence Within an Arteriovenous Graft","volume":"40","author":"Lee","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"key":"2019100513540728500_c16","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1016\/S0890-5096(06)62381-9","article-title":"Distal Anastomotic Intimal Hyperplasia: Histopathologic Character and Biogenesis","volume":"3","author":"Sottiurai","journal-title":"Ann. Vasc. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/0890-5096","issn-type":"print"},{"key":"2019100513540728500_c17","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1067\/mva.1992.33849","article-title":"Anastomotic Intimal Hyperplasia: Mechanical Injury or Flow Induced","volume":"15","author":"Bassiouny","journal-title":"J. Vasc. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/0741-5214","issn-type":"print"},{"key":"2019100513540728500_c18","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1007\/s10047-003-0232-x","article-title":"Intimal Hyperplasia and Hemodynamic Factors in Arterial Bypass and Arteriovenous Grafts: A Review","volume":"6","author":"Haruguchi","journal-title":"Int. J. Artif. Organs","ISSN":"https:\/\/id.crossref.org\/issn\/0391-3988","issn-type":"print"},{"key":"2019100513540728500_c19","doi-asserted-by":"publisher","first-page":"1087","DOI":"10.1115\/1.2073507","article-title":"Local and Global Geometric Influence on Steady Flow in Distal Anastomoses of Peripheral Bypass Grafts","volume":"127","author":"Giordana","journal-title":"ASME J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"key":"2019100513540728500_c20","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1161\/01.RES.77.5.869","article-title":"Fluid Shear Stress Stimulates Mitogen-Activated Protein Kinase in Endothelial Cells","volume":"77","author":"Tseng","journal-title":"Circ. Res.","ISSN":"https:\/\/id.crossref.org\/issn\/0009-7330","issn-type":"print"},{"key":"2019100513540728500_c21","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1016\/S0735-1097(04)01083-6","article-title":"Role of the Endothelium in Modulating Neointimal Formation: Vasculoprotective Approaches to Attenuate Restenosis After Percutaneous Coronary Intervention","volume":"44","author":"Kipshidze","journal-title":"J. Am. Coll. Cardiol.","ISSN":"https:\/\/id.crossref.org\/issn\/0735-1097","issn-type":"print"},{"key":"2019100513540728500_c22","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1097\/01.mat.0000201961.97981.e9","article-title":"Effect of Left Ventricular Assist Device Outflow Conduit Anastomosis Location on Flow Patterns in the Native Aorta","volume":"52","author":"May-Newman","journal-title":"ASAIO J.","ISSN":"https:\/\/id.crossref.org\/issn\/1058-2916","issn-type":"print"},{"key":"2019100513540728500_c23","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1097\/01.MAT.0000136505.27884.F8","article-title":"Effects of Left Ventricular Assist Device Support and Outflow Graft Location Upon Aortic Blood Flow","volume":"50","author":"Litwak","journal-title":"ASAIO J.","ISSN":"https:\/\/id.crossref.org\/issn\/1058-2916","issn-type":"print"},{"key":"2019100513540728500_c24","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1111\/j.1525-1594.2005.29100.x","article-title":"Ascending Aorta Outflow Graft Location and Pulsatile Ventricular Assist Provide Optimal Hemodynamic Support in an Adult Mock Circulation","volume":"29","author":"Litwak","journal-title":"Artif. Organs","ISSN":"https:\/\/id.crossref.org\/issn\/0160-564X","issn-type":"print"},{"key":"2019100513540728500_c25","doi-asserted-by":"publisher","first-page":"111005","DOI":"10.1115\/1.3212114","article-title":"Numerical Study of Blood Flow at the End-to-Side Anastomosis of a Left Ventricular Assist Device for Adult Patient","volume":"131","author":"Yang","journal-title":"ASME J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"key":"2019100513540728500_c26","doi-asserted-by":"publisher","first-page":"5685","DOI":"10.1016\/j.cma.2005.11.011","article-title":"A Coupled Momentum Method for Modeling Blood Flow in Three-Dimensional Deformable Arteries","volume":"195","author":"Figueroa","journal-title":"Comput. Methods Appl. Mech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0045-7825","issn-type":"print"},{"key":"2019100513540728500_c27","doi-asserted-by":"publisher","first-page":"3776","DOI":"10.1016\/j.cma.2005.04.014","article-title":"Outflow Boundary Conditions for Three-Dimensional Finite Element Modeling of Blood Flow and Pressure in Arteries","volume":"195","author":"Vignon-Clementel","journal-title":"Comput. Methods Appl. Mech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0045-7825","issn-type":"print"},{"key":"2019100513540728500_c28","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1115\/1.2895548","article-title":"Flow Dynamics in the Human Aorta","volume":"115","author":"Chandran","journal-title":"ASME J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"key":"2019100513540728500_c29","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1016\/S0003-4975(97)00445-1","article-title":"Morphologic Features of the Normal Aortic Arch in Neonates, Infants, and Children Pertinent to Growth","volume":"64","author":"Machii","journal-title":"Ann. Thorac. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/0003-4975","issn-type":"print"},{"key":"2019100513540728500_c30","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1097\/MAT.0b013e318155741d","article-title":"Anatomic Fit Assessment for the Penn State Pediatric Ventricular Assist Device","volume":"53","author":"Connell","journal-title":"ASAIO J.","ISSN":"https:\/\/id.crossref.org\/issn\/1058-2916","issn-type":"print"},{"key":"2019100513540728500_c31","doi-asserted-by":"publisher","first-page":"1228","DOI":"10.1063\/1.864272","article-title":"A Model for the Turbulent Energy Spectrum","volume":"26","author":"Driscoll","journal-title":"Phys. Fluids","ISSN":"https:\/\/id.crossref.org\/issn\/1070-6631","issn-type":"print"},{"key":"2019100513540728500_c32","doi-asserted-by":"publisher","first-page":"1416","DOI":"10.1063\/1.869254","article-title":"A Comparative Study of Subgrid Scale Models in Homogeneous Isotropic Turbulence","volume":"9","author":"Fureby","journal-title":"Phys. Fluids","ISSN":"https:\/\/id.crossref.org\/issn\/1070-6631","issn-type":"print"},{"issue":"1","key":"2019100513540728500_c33","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1006\/jcph.2002.7119","article-title":"Large Eddy Simulation of High-Reynolds-Number Free and Wall-Bounded Flows","volume":"181","author":"Fureby","journal-title":"J. Comput. Phys.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9991","issn-type":"print"},{"key":"2019100513540728500_c34","doi-asserted-by":"publisher","first-page":"1043","DOI":"10.1002\/fld.925","article-title":"On MILES Based on Flux-Limiting Algorithm","volume":"47","author":"Grinstein","journal-title":"Int. J. Numer. Methods Fluids","ISSN":"https:\/\/id.crossref.org\/issn\/0271-2091","issn-type":"print"},{"key":"2019100513540728500_c35","doi-asserted-by":"publisher","first-page":"1483","DOI":"10.1115\/1.2801684","article-title":"On Flux-Limiting-Based Implicit Large Eddy Simulation","volume":"129","author":"Grinstein","journal-title":"ASME J. Fluids Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0098-2202","issn-type":"print"},{"key":"2019100513540728500_c36","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1097\/MAT.0b013e318050d210","article-title":"Effect of Continuous and Pulsatile Flow Left Ventricular Assist on Pulsatility in a Pediatric Animal Model of Left Ventricular Dysfunction: Pilot Observations","volume":"53","author":"Pantalos","journal-title":"ASAIO J.","ISSN":"https:\/\/id.crossref.org\/issn\/1058-2916","issn-type":"print"},{"key":"2019100513540728500_c37","doi-asserted-by":"publisher","first-page":"1743","DOI":"10.1007\/s00467-007-0561-8","article-title":"Blood Pressure in the First Year of Life in Healthy Infants Born at Term","volume":"22","author":"Kent","journal-title":"Pediatr. Nephrol.","ISSN":"https:\/\/id.crossref.org\/issn\/0931-041X","issn-type":"print"},{"issue":"9","key":"2019100513540728500_c38","doi-asserted-by":"crossref","first-page":"1215","DOI":"10.1161\/01.CIR.99.9.1215","article-title":"Caval Contribution to Flow in the Branch Pulmonary Arteries of Fontan Patients With a Novel Application of Magnetic Resonance Presaturation Pulse","volume":"99","author":"Fogel","journal-title":"Circulation","ISSN":"https:\/\/id.crossref.org\/issn\/0009-7322","issn-type":"print"},{"key":"2019100513540728500_c39","volume-title":"OPENFOAM 1.5 User Guide"},{"key":"2019100513540728500_c40","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/0021-9991(86)90099-9","article-title":"Solution of the Implicitly Discretised Fluid Flow Equations by Operator-Splitting","volume":"62","author":"Issa","journal-title":"J. Comput. Phys.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9991","issn-type":"print"},{"key":"2019100513540728500_c41","doi-asserted-by":"crossref","volume-title":"The Physics of Pulsatile Flow","author":"Zamir","DOI":"10.1007\/978-1-4612-1282-9"},{"key":"2019100513540728500_c42","volume-title":"Mechanics of Materials","author":"Higdon"},{"issue":"2","key":"2019100513540728500_c43","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1007\/BF02648047","article-title":"An Automated Method for Analysis and Visualization of Laser Doppler Velocimetry Data","volume":"25","author":"Healy","journal-title":"Ann. Biomed. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0090-6964","issn-type":"print"},{"issue":"6","key":"2019100513540728500_c44","doi-asserted-by":"publisher","first-page":"672","DOI":"10.1002\/jmri.10119","article-title":"Nonuniform Flow Dynamics in the Aorta of Normal Children: A Simplified Approach to Measurement Using Magnetic Resonance Velocity Mapping","volume":"15","author":"Fogel","journal-title":"J. Magn. Reson Imaging","ISSN":"https:\/\/id.crossref.org\/issn\/1053-1807","issn-type":"print"},{"issue":"4","key":"2019100513540728500_c45","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1115\/1.1487357","article-title":"Unsteady and Three-Dimensional Simulation of Blood Flow in the Human Aortic Arch","volume":"124","author":"Shahcheraghi","journal-title":"ASME J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"issue":"6","key":"2019100513540728500_c46","doi-asserted-by":"publisher","first-page":"061012","DOI":"10.1115\/1.2978988","article-title":"Neonatal Aortic Arch Hemodynamics and Perfusion During Cardiopulmonary Bypass","volume":"130","author":"Pekkan","journal-title":"ASME J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"issue":"1","key":"2019100513540728500_c47","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1016\/S0003-4975(00)02208-6","article-title":"Left Hemispheric Strokes in Coronary Surgery: Implications for End-Hole Aortic Cannulas","volume":"71","author":"Weinstein","journal-title":"Ann. Thorac. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/0003-4975","issn-type":"print"},{"key":"2019100513540728500_c48","doi-asserted-by":"publisher","first-page":"1919","DOI":"10.1016\/S0003-4975(03)00018-3","article-title":"Echocardiographic Comparison of the Standard End-Hole Cannula, the Soft-Flow Cannula, and the Dispersion Cannula During Perfusion Into the Aortic Arch","volume":"75","author":"Grooters","journal-title":"Ann. Thorac. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/0003-4975","issn-type":"print"},{"key":"2019100513540728500_c49","first-page":"160","volume-title":"The Rheology of Blood Vessels and Associated Tissues","author":"Hellums"},{"issue":"6","key":"2019100513540728500_c50","doi-asserted-by":"crossref","first-page":"783","DOI":"10.3233\/BIR-1984-21605","article-title":"Human Red Blood Cell Hemolysis in a Turbulent Shear Flow: Contribution of Reynolds Shear Stresses","volume":"21","author":"Sallam","journal-title":"Biorheology","ISSN":"https:\/\/id.crossref.org\/issn\/0006-355X","issn-type":"print"},{"issue":"5","key":"2019100513540728500_c51","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1007\/s10439-008-9473-4","article-title":"The Flow Field Along the Entire Length of Mouse Aorta and Primary Branches","volume":"36","author":"Huo","journal-title":"Ann. Biomed. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0090-6964","issn-type":"print"},{"issue":"12","key":"2019100513540728500_c52","doi-asserted-by":"publisher","first-page":"1377","DOI":"10.1016\/0021-9290(93)90089-W","article-title":"Spatial and Temporal Variations of Wall Shear Stress Within an End-to-Side Arterial Anastomosis Model","volume":"26","author":"Ojha","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"},{"issue":"3","key":"2019100513540728500_c53","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1115\/1.1372323","article-title":"Hemodynamic Factors at the Distal End-to-Side Anastomosis of a Bypass Graft With Different POS:DOS Flow Ratios","volume":"123","author":"Li","journal-title":"ASME J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"issue":"5","key":"2019100513540728500_c54","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1161\/01.ATV.18.5.686","article-title":"Influence of Oscillatory and Unidirectional Flow Environments on the Expression of Endothelin and Nitric Oxide Synthase in Cultured Endothelial Cells","volume":"18","author":"Ziegler","journal-title":"Arterioscler., Thromb., Vasc. Biol.","ISSN":"https:\/\/id.crossref.org\/issn\/1079-5642","issn-type":"print"},{"issue":"21","key":"2019100513540728500_c55","doi-asserted-by":"publisher","first-page":"2035","DOI":"10.1001\/jama.282.21.2035","article-title":"Hemodynamic Shear Stress and Its Role in Atherosclerosis","volume":"282","author":"Malek","journal-title":"J. Am. Med. Assoc.","ISSN":"https:\/\/id.crossref.org\/issn\/0098-7484","issn-type":"print"},{"issue":"4","key":"2019100513540728500_c56","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1007\/s10554-007-9275-z","article-title":"CFD Analysis in an Anatomically Realistic Coronary Artery Model Based on Non-Invasive 3D Imaging: Comparison of Magnetic Resonance Imaging With Computed Tomography","volume":"24","author":"Goubergrits","journal-title":"Int. J. Cardiovasc. Imaging"},{"issue":"6","key":"2019100513540728500_c57","doi-asserted-by":"publisher","first-page":"1495","DOI":"10.1088\/0967-3334\/25\/6\/014","article-title":"Image-Based Carotid Flow Reconstruction: A Comparison Between MRI and Ultrasound","volume":"25","author":"Glor","journal-title":"Physiol. Meas","ISSN":"https:\/\/id.crossref.org\/issn\/0967-3334","issn-type":"print"},{"issue":"3","key":"2019100513540728500_c58","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/S0197-3975(97)00111-5","article-title":"Compliance Mismatch May Promote Graft-Artery Intimal Hyperplasia by Altering Suture-Line Stresses","volume":"31","author":"Ballyk","journal-title":"J. Biomech.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9290","issn-type":"print"}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4000872\/5771049\/031009_1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4000872\/5771049\/031009_1.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,5]],"date-time":"2019-10-05T17:54:16Z","timestamp":1570298056000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/doi\/10.1115\/1.4000872\/469979\/Hemodynamics-of-an-EndtoSide-Anastomotic-Graft-for"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,2,17]]},"references-count":58,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2010,3,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4000872","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,2,17]]},"article-number":"031009"}}