{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T13:34:28Z","timestamp":1789565668448,"version":"build-2803163510"},"reference-count":43,"publisher":"ASME International","issue":"1","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2011,1,1]]},"abstract":"<jats:p>The purpose of this study is to develop a 3D patient-specific finite element model (FEM) of the cornea and sclera to compare predicted and in vivo refractive outcomes and to estimate the corneal elastic property changes associated with each procedure. Both eyes of a patient who underwent laser-assisted in situ keratomileusis (LASIK) for myopic astigmatism were modeled. Pre- and postoperative Scheimpflug anterior and posterior corneal elevation maps were imported into a 3D corneo-scleral FEM with an unrestrained limbus. Preoperative corneal hyperelastic properties were chosen to account for meridional anisotropy. Inverse FEM was used to determine the undeformed corneal state that produced &lt;0.1% error in anterior elevation between simulated and in vivo preoperative geometries. Case-specific 3D aspheric ablation profiles were simulated, and corneal topography and spherical aberration were compared at clinical intraocular pressure. The magnitude of elastic weakening of the residual corneal bed required to maximize the agreement with clinical axial power was calculated and compared with the changes in ocular response analyzer (ORA) measurements. The models produced curvature maps and spherical aberrations equivalent to in vivo measurements. For the preoperative property values used in this study, predicted elastic weakening with LASIK was as high as 55% for a radially uniform model of residual corneal weakening and 65% at the point of maximum ablation in a spatially varying model of weakening. Reductions in ORA variables were also observed. A patient-specific FEM of corneal refractive surgery is presented, which allows the estimation of surgically induced changes in corneal elastic properties. Significant elastic weakening after LASIK was required to replicate clinical topographic outcomes in this two-eye pilot study.<\/jats:p>","DOI":"10.1115\/1.4002934","type":"journal-article","created":{"date-parts":[[2010,11,5]],"date-time":"2010-11-05T22:04:14Z","timestamp":1288994654000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":63,"title":["Patient-Specific Modeling of Corneal Refractive Surgery Outcomes and Inverse Estimation of Elastic Property Changes"],"prefix":"10.1115","volume":"133","author":[{"given":"Abhijit Sinha","family":"Roy","sequence":"first","affiliation":[{"name":"Cole Eye Institute, Cleveland Clinic, Cleveland, OH 44195"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"Jr.","given":"William J.","family":"Dupps","sequence":"additional","affiliation":[{"name":"Cole Eye Institute, Department of Biomedical Engineering, and Transplant Center, Surgery Institute, Cleveland Clinic, Cleveland, OH; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44195"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"33","published-online":{"date-parts":[[2010,12,22]]},"reference":[{"issue":"4","key":"2019100512344145000_c1","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1016\/j.ophtha.2008.12.037","article-title":"LASIK World Literature Review: Quality of Life and Patient Satisfaction","volume":"116","author":"Solomon","journal-title":"Ophthalmology","ISSN":"https:\/\/id.crossref.org\/issn\/0161-6420","issn-type":"print"},{"issue":"4","key":"2019100512344145000_c2","doi-asserted-by":"publisher","first-page":"331","DOI":"10.3928\/1081597X-20090401-06","article-title":"Effect of NIDEK Optimized Aspheric Transition Zone Ablation Profile on Higher Order Aberrations During LASIK for Myopia","volume":"25","author":"Kosaki","journal-title":"J. Refract. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/1081-597X","issn-type":"print"},{"issue":"3","key":"2019100512344145000_c3","doi-asserted-by":"crossref","first-page":"273","DOI":"10.3928\/1081597X-20090301-06","article-title":"Incidence, Outcomes, and Risk Factors for Retreatment After Wavefront-Optimized Ablations With PRK and LASIK","volume":"25","author":"Randleman","journal-title":"J. Refract. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/1081-597X","issn-type":"print"},{"issue":"2","key":"2019100512344145000_c4","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1016\/j.ajo.2005.08.034","article-title":"Wavefront-Guided Ablation: Evidence for Efficacy Compared to Traditional Ablation","volume":"141","author":"Netto","journal-title":"Am. J. Ophthalmol.","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9394","issn-type":"print"},{"issue":"7","key":"2019100512344145000_c5","doi-asserted-by":"publisher","first-page":"1249","DOI":"10.1016\/j.ophtha.2008.04.010","article-title":"Wavefront-Guided LASIK for the Correction of Primary Myopia and Astigmatism: A Report by the American Academy of Ophthalmology","volume":"115","author":"Schallhorn","journal-title":"Ophthalmology","ISSN":"https:\/\/id.crossref.org\/issn\/0161-6420","issn-type":"print"},{"issue":"6","key":"2019100512344145000_c6","doi-asserted-by":"publisher","first-page":"926","DOI":"10.1364\/JOSAA.21.000926","article-title":"Comparison of Real and Computer-Simulated Outcomes of LASIK Refractive Surgery","volume":"21","author":"Cano","journal-title":"J. Opt. Soc. Am. A Opt. Image Sci. Vis","ISSN":"https:\/\/id.crossref.org\/issn\/1084-7529","issn-type":"print"},{"key":"2019100512344145000_c7","doi-asserted-by":"crossref","first-page":"658","DOI":"10.3928\/1081-597X-20011101-05","article-title":"Effect of Acute Biomechanical Changes on Corneal Curvature After Photokeratectomy","volume":"17","author":"Dupps","journal-title":"J. Refract. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/1081-597X","issn-type":"print"},{"key":"2019100512344145000_c8","first-page":"S589","article-title":"Biomechanics of the Cornea and Wavefront-Guided Laser Refractive Surgery","volume":"18","author":"Roberts","journal-title":"J. Refract. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/1081-597X","issn-type":"print"},{"issue":"13","key":"2019100512344145000_c9","doi-asserted-by":"publisher","first-page":"6142","DOI":"10.1364\/OE.14.006142","article-title":"Experiments on PMMA Models to Predict the Impact of Corneal Refractive Surgery on Corneal Shape","volume":"14","author":"Dorronsoro","journal-title":"Opt. Express","ISSN":"https:\/\/id.crossref.org\/issn\/1094-4087","issn-type":"print"},{"issue":"5","key":"2019100512344145000_c10","first-page":"S592","article-title":"Increase in Corneal Asphericity After Standard Laser In Situ Keratomileusis for Myopia Is Not Inherent to the Munnerlyn Algorithm","volume":"19","author":"Marcos","journal-title":"J. Refract. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/1081-597X","issn-type":"print"},{"issue":"1","key":"2019100512344145000_c11","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1016\/j.jcrs.2004.09.044","article-title":"Prediction of Flap Response","volume":"31","author":"Potgieter","journal-title":"J. Cataract Refractive Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/0886-3350","issn-type":"print"},{"issue":"8","key":"2019100512344145000_c12","doi-asserted-by":"crossref","first-page":"800","DOI":"10.3928\/1081-597X-20071001-10","article-title":"Biomechanical Effects of Femtosecond and Microkeratome-Based Flap Creation: Prospective Contralateral Examination of Two Patients","volume":"23","author":"Krueger","journal-title":"J. Refract. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/1081-597X","issn-type":"print"},{"issue":"10","key":"2019100512344145000_c13","doi-asserted-by":"publisher","first-page":"875","DOI":"10.3928\/1081597X-20090917-09","article-title":"Effects of Altered Corneal Stiffness on Native and Postoperative LASIK Corneal Biomechanical Behavior: A Whole-Eye Finite Element Analysis","volume":"25","author":"Sinha Roy","journal-title":"J. Refract. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/1081-597X","issn-type":"print"},{"issue":"1","key":"2019100512344145000_c14","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1115\/1.2132368","article-title":"Biomechanical Modeling of Refractive Corneal Surgery","volume":"128","author":"Alastru\u00e9","journal-title":"ASME J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"issue":"3","key":"2019100512344145000_c15","doi-asserted-by":"crossref","first-page":"286","DOI":"10.3928\/1081-597X-20060301-15","article-title":"Refractive Change Induced by the LASIK Flap in a Biomechanical Finite Element Model","volume":"22","author":"Deenadayalu","journal-title":"J. Refract. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/1081-597X","issn-type":"print"},{"issue":"6","key":"2019100512344145000_c16","doi-asserted-by":"publisher","first-page":"061006","DOI":"10.1115\/1.2982251","article-title":"Three-Dimensional Modeling and Computational Analysis of the Human Cornea Considering Distributed Collagen Fibril Orientations","volume":"130","author":"Pandolfi","journal-title":"ASME J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"issue":"1","key":"2019100512344145000_c17","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1016\/j.jcrs.2008.09.015","article-title":"Lower- and Higher-Order Aberrations Predicted by an Optomechanical Model of Arcuate Keratotomy for Astigmatism","volume":"35","author":"Navarro","journal-title":"J. Cataract Refractive Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/0886-3350","issn-type":"print"},{"key":"2019100512344145000_c18","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/S0886-3350(88)80063-4","article-title":"Photorefractive Keratectomy: A Technique for Laser Refractive Surgery","volume":"14","author":"Munnerlyn","journal-title":"J. Cataract Refractive Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/0886-3350","issn-type":"print"},{"issue":"4","key":"2019100512344145000_c19","doi-asserted-by":"publisher","first-page":"775","DOI":"10.1016\/j.jcrs.2004.01.026","article-title":"Wavefront-Optimized Ablation Profiles: Theoretical Background","volume":"30","author":"Mrochen","journal-title":"J. Cataract Refractive Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/0886-3350","issn-type":"print"},{"issue":"4","key":"2019100512344145000_c20","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1016\/j.jcrs.2006.01.049","article-title":"Q-factor Customized Ablation Profile for the Correction of Myopic Astigmatism","volume":"32","author":"Koller","journal-title":"J. Cataract Refractive Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/0886-3350","issn-type":"print"},{"issue":"4","key":"2019100512344145000_c21","doi-asserted-by":"publisher","first-page":"044034","DOI":"10.1117\/1.2952189","article-title":"Optically Inspired Biomechanical Model of the Human Eyeball","volume":"13","author":"\u015ar\u00f3dka","journal-title":"J. Biomed. Opt.","ISSN":"https:\/\/id.crossref.org\/issn\/1083-3668","issn-type":"print"},{"key":"2019100512344145000_c22","doi-asserted-by":"publisher","first-page":"5288","DOI":"10.1167\/iovs.08-2890","article-title":"Anterior Chamber Angle Opening During Corneoscleral Indentation: The Mechanism of Whole Eye Globe Deformation and the Importance of the Limbus","volume":"50","author":"Amini","journal-title":"Invest. Ophthalmol. Visual Sci.","ISSN":"https:\/\/id.crossref.org\/issn\/0146-0404","issn-type":"print"},{"issue":"28","key":"2019100512344145000_c23","doi-asserted-by":"publisher","first-page":"3896","DOI":"10.1016\/j.biomaterials.2008.06.011","article-title":"Full-field Deformation of Bovine Cornea Under Constrained Inflation Conditions","volume":"29","author":"Boyce","journal-title":"Biomaterials","ISSN":"https:\/\/id.crossref.org\/issn\/0142-9612","issn-type":"print"},{"issue":"1","key":"2019100512344145000_c24","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.jcrs.2004.09.031","article-title":"Influence of Corneal Biomechanical Properties on Intraocular Pressure Measurement: Quantitative Analysis","volume":"31","author":"Liu","journal-title":"J. Cataract Refractive Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/0886-3350","issn-type":"print"},{"issue":"1","key":"2019100512344145000_c25","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.ajo.2006.09.036","article-title":"Changes in Corneal Biomechanics and Intraocular Pressure Following LASIK Using Static, Dynamic, and Noncontact Tonometry","volume":"143","author":"Pepose","journal-title":"Am. J. Ophthalmol.","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9394","issn-type":"print"},{"issue":"4","key":"2019100512344145000_c26","doi-asserted-by":"crossref","first-page":"366","DOI":"10.3928\/1081597X-20080401-09","article-title":"Measurement of Intraocular Pressure in LASIK and LASEK Patients Using the Reichert Ocular Response Analyzer and Goldmann Applanation Tonometry","volume":"24","author":"Kirwan","journal-title":"J. Refract. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/1081-597X","issn-type":"print"},{"issue":"1","key":"2019100512344145000_c27","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1177\/112067210501500113","article-title":"Central Corneal Thickness and Intraocular Pressure Relationship in Eyes With and Without Previous LASIK: Comparison of Goldmann Applanation Tonometer With Pneumatonometer","volume":"15","author":"Bayraktar","journal-title":"Eur. J. Ophthalmol.","ISSN":"https:\/\/id.crossref.org\/issn\/1120-6721","issn-type":"print"},{"issue":"9","key":"2019100512344145000_c28","doi-asserted-by":"publisher","first-page":"3790","DOI":"10.1167\/iovs.02-0946","article-title":"Intraocular Pressure Measurements Using Dynamic Contour Tonometry After Laser In Situ Keratomileusis","volume":"44","author":"Kaufmann","journal-title":"Invest. Ophthalmol. Visual Sci.","ISSN":"https:\/\/id.crossref.org\/issn\/0146-0404","issn-type":"print"},{"issue":"2","key":"2019100512344145000_c29","doi-asserted-by":"crossref","first-page":"178","DOI":"10.3928\/1081597X-20080201-09","article-title":"Experimental Assessment of Corneal Anisotropy","volume":"24","author":"Elsheikh","journal-title":"J. Refract. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/1081-597X","issn-type":"print"},{"issue":"1","key":"2019100512344145000_c30","doi-asserted-by":"crossref","first-page":"66","DOI":"10.3928\/1081-597X-20070101-11","article-title":"Surface Wave Elastometry of the Cornea in Porcine and Human Donor Eyes","volume":"23","author":"Dupps","journal-title":"J. Refract. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/1081-597X","issn-type":"print"},{"issue":"3","key":"2019100512344145000_c31","doi-asserted-by":"publisher","first-page":"1227","DOI":"10.1167\/iovs.08-1960","article-title":"Biomechanical Effects of Intraocular Pressure Elevation on Optic Nerve\/Lamina Cribrosa Before and After Peripapillary Scleral Collagen Cross-Linking","volume":"50","author":"Thornton","journal-title":"Invest. Ophthalmol. Visual Sci.","ISSN":"https:\/\/id.crossref.org\/issn\/0146-0404","issn-type":"print"},{"key":"2019100512344145000_c32","article-title":"Calculation of Corneal Spherical Aberration for Aspheric IOL Selection","author":"Sarver"},{"issue":"10","key":"2019100512344145000_c33","doi-asserted-by":"publisher","first-page":"1774","DOI":"10.1016\/j.jcrs.2009.05.041","article-title":"Postoperative Changes in Intraocular Pressure and Corneal Biomechanical Metrics Laser In Situ Keratomileusis Versus Laser-Assisted Subepithelial Keratectomy","volume":"35","author":"Qazi","journal-title":"J. Cataract Refractive Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/0886-3350","issn-type":"print"},{"issue":"12","key":"2019100512344145000_c34","doi-asserted-by":"publisher","first-page":"5337","DOI":"10.1167\/iovs.06-0557","article-title":"Corneal Thickness- and Age-Related Biomechanical Properties of the Cornea Measured With the Ocular Response Analyzer","volume":"47","author":"Kotecha","journal-title":"Invest. Ophthalmol. Visual Sci.","ISSN":"https:\/\/id.crossref.org\/issn\/0146-0404","issn-type":"print"},{"issue":"3","key":"2019100512344145000_c35","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1016\/j.clae.2009.02.005","article-title":"The Use of the Ocular Response Analyser to Determine Corneal Hysteresis in Eyes Before and After Excimer Laser Refractive Surgery","volume":"32","author":"Shah","journal-title":"Contact Lens & Anterior Eye"},{"issue":"8","key":"2019100512344145000_c36","doi-asserted-by":"publisher","first-page":"1371","DOI":"10.1016\/j.jcrs.2007.04.021","article-title":"Corneal Biomechanical Properties in Normal, Post-Laser In Situ Keratomileusis, and Keratoconic Eyes","volume":"33","author":"Ortiz","journal-title":"J. Cataract Refractive Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/0886-3350","issn-type":"print"},{"issue":"2","key":"2019100512344145000_c37","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1111\/j.1600-0420.2007.01023.x","article-title":"Corneal Hysteresis Using the Reichert Ocular Response Analyser: Findings Pre- and Post-LASIK and LASEK","volume":"86","author":"Kirwan","journal-title":"Acta Ophthalmologica"},{"issue":"9","key":"2019100512344145000_c38","doi-asserted-by":"publisher","first-page":"1499","DOI":"10.1016\/j.jcrs.2007.07.008","article-title":"Hysteresis: New Mechanospeak for the Ophthalmologist","volume":"33","author":"Dupps","journal-title":"J. Cataract Refractive Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/0886-3350","issn-type":"print"},{"issue":"9","key":"2019100512344145000_c39","doi-asserted-by":"publisher","first-page":"3919","DOI":"10.1167\/iovs.07-1321","article-title":"A Viscoelastic Biomechanical Model of the Cornea Describing the Effect of Viscosity and Elasticity on Hysteresis","volume":"49","author":"Glass","journal-title":"Invest. Ophthalmol. Visual Sci.","ISSN":"https:\/\/id.crossref.org\/issn\/0146-0404","issn-type":"print"},{"issue":"6","key":"2019100512344145000_c40","doi-asserted-by":"publisher","first-page":"947","DOI":"10.1016\/j.jcrs.2009.12.032","article-title":"Differences in the Early Biomechanical Effects of Hyperopic and Myopic Laser in situ Keratomileusis","volume":"36","author":"de Medeiros","journal-title":"J. Cataract Refractive Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/0886-3350","issn-type":"print"},{"issue":"4","key":"2019100512344145000_c41","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1016\/j.exer.2006.03.015","article-title":"Biomechanics and Wound Healing in the Cornea","volume":"83","author":"Dupps","journal-title":"Exp. Eye Res.","ISSN":"https:\/\/id.crossref.org\/issn\/0014-4835","issn-type":"print"},{"issue":"5","key":"2019100512344145000_c42","doi-asserted-by":"crossref","first-page":"433","DOI":"10.3928\/1081-597X-20050901-04","article-title":"Cohesive Tensile Strength of Human LASIK Wounds With Histologic, Ultrastructural, and Clinical Correlations","volume":"21","author":"Schmack","journal-title":"J. Refract. Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/1081-597X","issn-type":"print"},{"key":"2019100512344145000_c43","article-title":"OCT Elastography by Pressure-Induced Optical Feature Flow. Progress in Biomedical Optics and Imaging","author":"Ford"}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4002934\/5667595\/011002_1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4002934\/5667595\/011002_1.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,27]],"date-time":"2025-02-27T16:39:58Z","timestamp":1740674398000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/doi\/10.1115\/1.4002934\/465708\/PatientSpecific-Modeling-of-Corneal-Refractive"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,12,22]]},"references-count":43,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2011,1,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4002934","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,12,22]]},"article-number":"011002"}}