{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T04:15:14Z","timestamp":1790223314342,"version":"4.1.0"},"reference-count":46,"publisher":"ASME International","issue":"2","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2012,2,1]]},"abstract":"<jats:p>Modeling of the cerebrospinal fluid (CSF) system in the spine is strongly motivated by the need to understand the origins of pathological conditions such as the emergence and growth of fluid-filled cysts in the spinal cord. In this study, a one-dimensional (1D) approximation for the flow in elastic conduits was used to formulate a model of the spinal CSF compartment. The modeling was based around a coaxial geometry in which the inner elastic cylinder represented the spinal cord, middle elastic tube represented the dura, and the outermost tube represented the vertebral column. The fluid-filled annuli between the cord and dura, and the dura and vertebral column, represented the subarachnoid and epidural spaces, respectively. The system of governing equations was constructed by applying a 1D form of mass and momentum conservation to all segments of the model. The developed 1D model was used to simulate CSF pulse excited by pressure disturbances in the subarachnoid and epidural spaces. The results were compared to those obtained from an equivalent two-dimensional finite element (FE) model which was implemented using a commercial software package. The analysis of linearized governing equations revealed the existence of three types of waves, of which the two slower waves can be clearly related to the wave modes identified in previous similar studies. The third, much faster, wave emanates directly from the vertebral column and has little effect on the deformation of the spinal cord. The results obtained from the 1D model and its FE counterpart were found to be in good general agreement even when sharp spatial gradients of the spinal cord stiffness were included; both models predicted large radial displacements of the cord at the location of an initial cyst. This study suggests that 1D modeling, which is computationally inexpensive and amenable to coupling with the models of the cranial CSF system, should be a useful approach for the analysis of some aspects of the CSF dynamics in the spine. The simulation of the CSF pulse excited by a pressure disturbance in the epidural space, points to the possibility that regions of the spinal cord with abnormally low stiffness may be prone to experiencing large strains due to coughing and sneezing.<\/jats:p>","DOI":"10.1115\/1.4005853","type":"journal-article","created":{"date-parts":[[2012,2,1]],"date-time":"2012-02-01T23:03:45Z","timestamp":1328137425000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":22,"title":["A One-Dimensional Model of the Spinal Cerebrospinal-Fluid Compartment"],"prefix":"10.1115","volume":"134","author":[{"given":"Srdjan","family":"Cirovic","sequence":"first","affiliation":[{"name":"The Centre for Biomedical Engineering, University of Surrey, Guildford, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minsuok","family":"Kim","sequence":"additional","affiliation":[{"name":"The Centre for Biomedical Engineering, University of Surrey, Guildford, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"33","published-online":{"date-parts":[[2012,3,19]]},"reference":[{"issue":"9","key":"2019100412312831000_c1","doi-asserted-by":"publisher","first-page":"1024","DOI":"10.1016\/j.compbiomed.2008.07.004","article-title":"A Review of Physiological Simulation Models of Intracranial Pressure Dynamics","volume":"38","author":"Wakeland","journal-title":"Comput. Biol. Med."},{"issue":"1","key":"2019100412312831000_c2","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1093\/imammb\/dqn021","article-title":"Analytic Solution During an Infusion Test of the Linear Unsteady Poroelastic Equations in a Spherically Symmetric Model of the Brain","volume":"26","author":"Wirth","journal-title":"Math. Med. Biol."},{"issue":"3","key":"2019100412312831000_c3","doi-asserted-by":"publisher","first-page":"955","DOI":"10.1007\/s10439-010-9923-7","article-title":"A Model of Cerebrovascular Reactivity Including the Circle of Willis and Cortical Anastomoses","volume":"38","author":"Ursino","journal-title":"Ann. Biomed. Eng."},{"issue":"12","key":"2019100412312831000_c4","doi-asserted-by":"publisher","first-page":"958","DOI":"10.1109\/TBME.1987.325935","article-title":"A Simulation Study of Intracranial Pressure Increment Using an Electrical Circuit Model of Cerebral Circulation","volume":"34","author":"Takemae","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"3","key":"2019100412312831000_c5","doi-asserted-by":"publisher","first-page":"332","DOI":"10.3171\/jns.1978.48.3.0332","article-title":"A Nonlinear Analysis of the Cerebrospinal Fluid System and Intracranial Pressure Dynamics","volume":"48","author":"Marmarou","journal-title":"J. Neurosurg."},{"issue":"5","key":"2019100412312831000_c6","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1007\/BF02345321","article-title":"Mathematical Study of the Role of Non-Linear Venous Compliance in the Cranial Volume-Pressure Test","volume":"41","author":"Cirovic","journal-title":"Med. Biol. Eng. Comput."},{"issue":"3","key":"2019100412312831000_c7","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1109\/TBME.2006.890492","article-title":"A New Lumped-Parameter Model of Cerebrospinal Hydrodynamics During the Cardiac Cycle in Healthy Volunteers","volume":"54","author":"Ambarki","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"2019100412312831000_c8","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1186\/1743-8454-6-17","article-title":"The Influence of Coughing on Cerebrospinal Fluid Pressure in an In Vitro Syringomyelia Model With Spinal Subarachnoid Space Stenosis","volume":"6","author":"Martin","journal-title":"Cerebrospinal Fluid Res."},{"issue":"11","key":"2019100412312831000_c9","doi-asserted-by":"publisher","first-page":"111007","DOI":"10.1115\/1.4000089","article-title":"Spinal Subarachnoid Space Pressure Measurements in an In Vitro Spinal Stenosis Model: Implications on Syringomyelia Theories","volume":"132","author":"Martin","journal-title":"J. Biomech. Eng."},{"issue":"7","key":"2019100412312831000_c10","doi-asserted-by":"publisher","first-page":"1110","DOI":"10.1115\/1.2073687","article-title":"Syringomyelia Hydrodynamics: An In Vitro Study Based on In Vivo Measurements","volume":"127","author":"Martin","journal-title":"J. Biomech. Eng."},{"issue":"7","key":"2019100412312831000_c11","doi-asserted-by":"publisher","first-page":"874","DOI":"10.1016\/j.medengphy.2010.07.009","article-title":"A Lumped-Parameter Model of the Cerebrospinal System for Investigating Arterial-Driven Flow in Posttraumatic Syringomyelia","volume":"33","author":"Elliott","journal-title":"Med. Eng. Phys."},{"issue":"2","key":"2019100412312831000_c12","doi-asserted-by":"publisher","first-page":"021008","DOI":"10.1115\/1.3005159","article-title":"A Coaxial Tube Model of the Cerebrospinal Fluid Pulse Propagation in the Spinal Column","volume":"131","author":"Cirovic","journal-title":"J. Biomech. Eng."},{"issue":"5","key":"2019100412312831000_c13","doi-asserted-by":"publisher","first-page":"754","DOI":"10.1136\/jnnp.2003.018671","article-title":"Theoretical Analysis of the Pathophysiology of Syringomyelia Associated With Adhesive Arachnoiditis","volume":"75","author":"Chang","journal-title":"J. Neurol., Neurosurg. Psychiatry"},{"issue":"3","key":"2019100412312831000_c14","doi-asserted-by":"publisher","first-page":"344","DOI":"10.1136\/jnnp.74.3.344","article-title":"Hypothesis on the Pathophysiology of Syringomyelia Based on Simulation of Cerebrospinal Fluid Dynamics","volume":"74","author":"Chang","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"issue":"6","key":"2019100412312831000_c15","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1115\/1.1634281","article-title":"Pressure Wave Propagation in Fluid-Filled Co-Axial Elastic Tubes. Part 2: Mechanisms for the Pathogenesis of Syringomyelia","volume":"125","author":"Carpenter","journal-title":"J. Biomech. Eng."},{"issue":"7","key":"2019100412312831000_c16","doi-asserted-by":"publisher","first-page":"1099","DOI":"10.1115\/1.2073607","article-title":"The Origins of Syringomyelia: Numerical Models of Fluid\/Structure Interactions in the Spinal Cord","volume":"127","author":"Bertram","journal-title":"J. Biomech. Eng."},{"issue":"7","key":"2019100412312831000_c17","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1007\/s11517-008-0332-0","article-title":"Tensile Radial Stress in the Spinal Cord Related to Arachnoiditis or Tethering: A Numerical Model","volume":"46","author":"Bertram","journal-title":"Med. Biol. Eng. Comput."},{"issue":"6","key":"2019100412312831000_c18","doi-asserted-by":"publisher","first-page":"061009","DOI":"10.1115\/1.4001165","article-title":"Evaluation By Fluid\/Structure-Interaction Spinal-Cord Simulation of the Effects of Subarachnoid-Space Stenosis on an Adjacent Syrinx","volume":"132","author":"Bertram","journal-title":"J. Biomech. Eng."},{"key":"2019100412312831000_c19","doi-asserted-by":"publisher","first-page":"1189","DOI":"10.1016\/j.jfluidstructs.2009.06.008","article-title":"A Numerical Investigation of Waves Propagating in the Spinal Cord and Subarachnoid Space in the Presence of a Syrinx","volume":"25","author":"Bertram","journal-title":"J. Fluids Struct."},{"issue":"6","key":"2019100412312831000_c20","doi-asserted-by":"publisher","first-page":"852","DOI":"10.1115\/1.1634280","article-title":"Pressure Wave Propagation in Fluid-Filled Co-Axial Elastic Tubes. Part 1: Basic Theory","volume":"125","author":"Berkouk","journal-title":"J. Biomech. Eng."},{"issue":"11","key":"2019100412312831000_c21","doi-asserted-by":"crossref","first-page":"798","DOI":"10.1177\/014107688007301109","article-title":"On the Pathogenesis of Syringomyelia: A Review","volume":"73","author":"Williams","journal-title":"J. R. Soc. Med."},{"issue":"1\u20132","key":"2019100412312831000_c22","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.jns.2004.01.014","article-title":"The Pathogenesis of Syringomyelia Associated With Lesions at the Foramen Magnum: A Critical Review of Existing Theories and Proposal of a New Hypothesis","volume":"220","author":"Levine","journal-title":"J. Neurol. Sci."},{"issue":"1","key":"2019100412312831000_c23","doi-asserted-by":"publisher","first-page":"3","DOI":"10.3171\/jns.1994.80.1.0003","article-title":"Pathophysiology of Syringomyelia Associated With Chiari I Malformation of the Cerebellar Tonsils. Implications for Diagnosis and Treatment","volume":"80","author":"Oldfield","journal-title":"J. Neurosurg."},{"issue":"4","key":"2019100412312831000_c24","doi-asserted-by":"publisher","first-page":"553","DOI":"10.3171\/jns.1999.91.4.0553","article-title":"Elucidating the Pathophysiology of Syringomyelia","volume":"91","author":"Heiss","journal-title":"J. Neurosurg."},{"issue":"4","key":"2019100412312831000_c25","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1016\/S0967-5868(02)00326-0","article-title":"Post-Traumatic Syringomyelia: A Review","volume":"10","author":"Brodbelt","journal-title":"J. Clin. Neurosci."},{"issue":"3\u20134","key":"2019100412312831000_c26","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1007\/BF01407124","article-title":"Simultaneous Cerebral and Spinal Fluid Pressure Recordings. I. Technique, Physiology, and Normal Results","volume":"58","author":"Williams","journal-title":"Acta Neurochir. (Wien)"},{"issue":"2","key":"2019100412312831000_c27","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1093\/brain\/99.2.331","article-title":"Cerebrospinal Fluid Pressure Changes in Response to Coughing","volume":"99","author":"Williams","journal-title":"Brain"},{"issue":"12","key":"2019100412312831000_c28","doi-asserted-by":"publisher","first-page":"1015","DOI":"10.1016\/0021-9290(86)90118-1","article-title":"A Global Mathematical Model of the Cerebral Circulation in Man","volume":"19","author":"Zagzoule","journal-title":"J. Biomech."},{"issue":"1","key":"2019100412312831000_c29","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1007\/BF02522938","article-title":"Computational Simulation of Blood Flow in Human Systemic Circulation Incorporating an External Force Field","volume":"33","author":"Sheng","journal-title":"Med. Biol. Eng. Comput."},{"issue":"1","key":"2019100412312831000_c30","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/0141-5425(91)90038-9","article-title":"Numerical Schemes for Unsteady Fluid Flow Through Collapsible Tubes","volume":"13","author":"Elad","journal-title":"J. Biomed. Eng."},{"issue":"1","key":"2019100412312831000_c31","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1016\/S0021-9290(01)00159-2","article-title":"A Model for Time-Dependent Flow in (Giraffe Jugular) Veins: Uniform Tube Properties","volume":"35","author":"Brook","journal-title":"J. Biomech."},{"issue":"4","key":"2019100412312831000_c32","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1111\/ana.1986.41.issue-4","article-title":"The Width of the Posterior Epidural Space in Obstetric Patients","volume":"41","author":"Nickalls","journal-title":"Anaesthesia"},{"issue":"3","key":"2019100412312831000_c33","first-page":"163","article-title":"The Anatomy of the Thoracic Spinal Canal Investigated With Magnetic Resonance Imaging (MRI)","volume":"58","author":"Lee","journal-title":"Acta Anaesthesiol. Belg."},{"issue":"1","key":"2019100412312831000_c34","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1115\/1.1336144","article-title":"Hydrodynamic Modeling of Cerebrospinal Fluid Motion Within the Spinal Cavity","volume":"123","author":"Loth","journal-title":"J. Biomech. Eng."},{"issue":"5","key":"2019100412312831000_c35","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1002\/(ISSN)1098-2353","article-title":"The Spinal Epidural Space","volume":"12","author":"Newell","journal-title":"Clin. Anat."},{"key":"2019100412312831000_c36","article-title":"Characteristics and Rieman Problems for Linear Hyperbolic Equations","volume-title":"Finite Volume Methods for Hyperbolic Problems","author":"Leveque"},{"issue":"3","key":"2019100412312831000_c37","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1179\/016164111X12962202723805","article-title":"Cerebrospinal Fluid Hydrodynamics in Type I Chiari Malformation","volume":"33","author":"Shaffer","journal-title":"Neurol. Res."},{"issue":"3","key":"2019100412312831000_c38","doi-asserted-by":"publisher","first-page":"E3","DOI":"10.3171\/foc.2000.8.3.3","article-title":"Cerebrospinal Fluid Flow Dynamics Study in Chiari I Malformation: Implications for Syrinx Formation","volume":"8","author":"Pinna","journal-title":"Neurosurg. Focus"},{"issue":"3","key":"2019100412312831000_c39","doi-asserted-by":"publisher","first-page":"E4","DOI":"10.3171\/foc.2000.8.3.4","article-title":"The \u2018Presyrinx\u2019 State: Is there a Reversible Myelopathic Condition That May Precede Syringomyelia?","volume":"8","author":"Fischbein","journal-title":"Neurosurg. Focus"},{"issue":"4","key":"2019100412312831000_c40","doi-asserted-by":"publisher","first-page":"716","DOI":"10.1016\/j.jns.2004.01.014","article-title":"Stenosis of Central Canal of Spinal Cord in Man: Incidence and Pathological Findings in 232 Autopsy Cases","volume":"80","author":"Milhorat","journal-title":"J Neurosurg"},{"key":"2019100412312831000_c41","doi-asserted-by":"crossref","unstructured":"Cirovic, S., and Kim, M., 2010, \u201cOne-Dimensional Model for Cerebrospinal Fluid Pulse in the Spinal Column,\u201d 6th World Congress of Biomechanics (WCB 2010), August 1-6 Singapore, IFMBE Proceedings. J. C. H.Goh, et al., eds., Singapore, 31, pp. 366\u2013369.","DOI":"10.1007\/978-3-642-14515-5_94"},{"issue":"8","key":"2019100412312831000_c42","doi-asserted-by":"publisher","first-page":"1029","DOI":"10.1006\/jfls.2002.0457","article-title":"Wave Propagation in a System of Coaxial Tubes Filled With Incompressible Media: A Model of Pulse Transmission in the Intracranial Arteries","volume":"16","author":"Cirovic","journal-title":"J. Fluids Struct."},{"issue":"6","key":"2019100412312831000_c43","doi-asserted-by":"publisher","first-page":"1765","DOI":"10.1109\/TBME.2008.2011647","article-title":"Mr Measurement of Cerebrospinal Fluid Velocity Wave Speed in the Spinal Canal","volume":"56","author":"Kalata","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"2","key":"2019100412312831000_c44","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1002\/(ISSN)1097-0185","article-title":"Morphology of the Human Internal Vertebral Venous Plexus: A Cadaver Study After Intravenous Araldite Cy 221 Injection","volume":"249","author":"Groen","journal-title":"Anat. Rec."},{"key":"2019100412312831000_c45","first-page":"1","article-title":"The Vertebral System of Veins as a Means for Cancer Dissemination","volume":"3","author":"Batson","journal-title":"Prog. Clin. Cancer"},{"issue":"5","key":"2019100412312831000_c46","doi-asserted-by":"publisher","first-page":"941","DOI":"10.3174\/ajnr.A1489","article-title":"Characterization of Csf Hydrodynamics in the Presence and Absence of Tonsillar Ectopia by Means of Computational Flow Analysis","volume":"30","author":"Roldan","journal-title":"AJNR Am. J. Neuroradiol."}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4005853\/5575480\/021005_1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4005853\/5575480\/021005_1.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,4]],"date-time":"2019-10-04T16:31:35Z","timestamp":1570206695000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/doi\/10.1115\/1.4005853\/450904\/A-OneDimensional-Model-of-the-Spinal"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,2,1]]},"references-count":46,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2012,2,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4005853","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,2,1]]},"article-number":"021005"}}