{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T23:48:25Z","timestamp":1769212105582,"version":"3.49.0"},"reference-count":48,"publisher":"ASME International","issue":"4","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2013,4,1]]},"abstract":"<jats:p>An analytical approach which is popular in micromechanical studies has been extended to the solution for the interference fit problem of the femoral stem in cementless total hip arthroplasty (THA). The multiple inhomogeneity problem of THA in transverse plane, including an elliptical stem, a cortical wall, and a cancellous layer interface, was formulated using the equivalent inclusion method (EIM) to obtain the induced interference elastic fields. Results indicated a maximum interference fit of about 210\u2009\u03bcm before bone fracture, predicted based on the Drucker\u2013Prager criterion for a partially reamed section. The cancellous layer had a significant effect on reducing the hoop stresses in the cortical wall; the maximum press fit increased to as high as 480\u2009\u03bcm for a 2\u2009mm thick cancellous. The increase of the thickness and the mechanical quality, i.e., stiffness and strength, of the cortical wall also increased the maximum interference fit before fracture significantly. No considerable effect was found for the implant material on the maximum allowable interference fit. It was concluded that while larger interference fits could be adapted for younger patients, care must be taken when dealing with the elderly and those suffering from osteoporosis. A conservative reaming procedure is beneficial for such patients; however, in order to ensure sufficient primary stability without risking bone fracture, a preoperative analysis might be necessary.<\/jats:p>","DOI":"10.1115\/1.4023699","type":"journal-article","created":{"date-parts":[[2013,2,20]],"date-time":"2013-02-20T23:23:11Z","timestamp":1361402591000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":13,"title":["An Analytical Approach to Study the Intraoperative Fractures of Femoral Shaft During Total Hip Arthroplasty"],"prefix":"10.1115","volume":"135","author":[{"given":"Leila","family":"Malekmotiei","sequence":"first","affiliation":[{"name":"Department of Civil Engineering, Sharif University of Technology, P.O. Box 11155-9313, Tehran, Iran e-mail:"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Farzam","family":"Farahmand","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, Sharif University of Technology, P.O. Box 11155-9567, Tehran, Iran e-mail:"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hossein M.","family":"Shodja","sequence":"additional","affiliation":[{"name":"Department of Civil Engineering, Sharif University of Technology, P.O. Box 11155-9313, Tehran, Iran; Institute for Nanoscience and Nanotechnology, Sharif University of Technology, P.O. Box 11155-9161, Tehran, Iran e-mail:"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aref","family":"Samadi-Dooki","sequence":"additional","affiliation":[{"name":"Department of Civil Engineering, Sharif University of Technology, P.O. Box 11155-9313, Tehran, Iran e-mail:"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"33","published-online":{"date-parts":[[2013,4,2]]},"reference":[{"key":"2019100601341618100_B1","first-page":"109","article-title":"Primary Total Hip Arthroplasty with a Second-Generation Cementless Total Hip Prosthesis in Patients Younger Than Fifty Years of Age","volume":"85A","year":"2003","journal-title":"J. Bone Jt. Surg."},{"key":"2019100601341618100_B2","first-page":"183","article-title":"Epidemiology of Periprosthetic Fractures After Major Joint Replacement: Hip and Knee","volume":"30","year":"1999","journal-title":"Orthop. Clin. North Am."},{"key":"2019100601341618100_B3","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1016\/j.injury.2007.02.048","article-title":"Epidemiology of Periprosthetic Femur Fracture Around a Total Hip Arthroplasty","volume":"38","year":"2007","journal-title":"Injury"},{"issue":"9","key":"2019100601341618100_B4","doi-asserted-by":"crossref","first-page":"2377","DOI":"10.1007\/s11999-010-1314-8","article-title":"Intraoperative Femur Fracture is Associated with Stem and Instrument Design in Primary Total Hip Arthroplasty","volume":"468","year":"2010","journal-title":"Clin. Orthop. Relat. Res."},{"key":"2019100601341618100_B5","first-page":"210","article-title":"Reaming Technique of the Femoral Diaphysis in Cementless Total Hip Arthroplasty","volume":"311","year":"1995","journal-title":"Clin. Orthop. Relat. Res."},{"key":"2019100601341618100_B6","first-page":"1085","article-title":"Press-Fit Components","volume-title":"The Adult Hip","year":"2007"},{"issue":"5","key":"2019100601341618100_B7","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1002\/jor.1100120507","article-title":"Fit of the Uncemented Femoral Component and the Use of Cement Influence the Strain Transfer the Femoral Cortex","volume":"12","year":"1994","journal-title":"J. Orthop. Res."},{"issue":"1","key":"2019100601341618100_B8","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1115\/1.2133766","article-title":"Cortical Bone Viscoelasticity and Fixation Strength of Press-Fit Femoral Stems: an In-Vitro Model","volume":"128","year":"2006","journal-title":"ASME J. Biomech. Eng."},{"issue":"1","key":"2019100601341618100_B9","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1115\/1.2133765","article-title":"Cortical Bone Viscoelasticity and Fixation Strength of Press-Fit Femoral Stems: A Finite Element Model","volume":"128","year":"2006","journal-title":"ASME J. Biomech. Eng."},{"key":"2019100601341618100_B10","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1016\/j.jbiomech.2007.10.009","article-title":"Finite Element Modeling of Primary Hip Stem Stability: The Effect of Interference Fit","volume":"41","year":"2008","journal-title":"J. Biomech."},{"key":"2019100601341618100_B11","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1007\/s11845-009-0442-1","article-title":"Periprosthetic Fractures May be More Likely in Cementless Femoral Stems with Sharp Edges","volume":"179","year":"2010","journal-title":"Ir. J. Med. Sci."},{"issue":"2","key":"2019100601341618100_B12","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1002\/(SICI)1097-4636(199708)36:2<274::AID-JBM17>3.0.CO;2-G","article-title":"Factors Influencing Stability at the Interface Between a Porous Surface and Cancellous Bone: A Finite Element Analysis of a Canine In Vivo Micromotion Experiment","volume":"36","year":"1997","journal-title":"J. Biomed. Mater. Res."},{"key":"2019100601341618100_B13","doi-asserted-by":"crossref","first-page":"1611","DOI":"10.1016\/S0021-9290(00)00140-8","article-title":"Large-Sliding Contact Elements Accurately Predict Levels of Bone\u2013Implant Micromotion Relevant to Osseointegration","volume":"33","year":"2000","journal-title":"J. Biomech."},{"issue":"1","key":"2019100601341618100_B14","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1302\/0301-620X.81B1.0810143","article-title":"Determination of the Hounsfield Value for CT\u2013Based Design of Custom Femoral Stems","volume":"81","year":"1999","journal-title":"J. Bone Jt. Surg."},{"key":"2019100601341618100_B15","doi-asserted-by":"crossref","first-page":"1809","DOI":"10.1016\/j.engfracmech.2003.08.003","article-title":"Modelling Bone Tissue Fracture and Healing: A Review","volume":"71","year":"2004","journal-title":"Eng. Fract. Mech."},{"key":"2019100601341618100_B16","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.jbiomech.2004.03.003","article-title":"Tensile and Compressive Stress Yield Criteria for Cancellous Bone","volume":"38","year":"2005","journal-title":"J. Biomech."},{"key":"2019100601341618100_B17","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1016\/j.medengphy.2007.12.001","article-title":"Constitutive Modelling of Inelastic Behaviour of Cortical Bone","volume":"30","year":"2008","journal-title":"Med. Eng. Phys."},{"key":"2019100601341618100_B18","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1002\/jor.1100170418","article-title":"Isotropy of Uniaxial Yield Strains for Bovine Trabecular Bone","volume":"17","year":"1999","journal-title":"J. Orthop. Res."},{"key":"2019100601341618100_B19","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1016\/S0021-9290(01)00011-2","article-title":"Dependence of Yield Strain of Human Trabecular Bone on Anatomic Site","volume":"34","year":"2001","journal-title":"J. Biomech."},{"key":"2019100601341618100_B20","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1115\/1.2798339","article-title":"A Cellular Solid Criterion for Predicting the Axial-Shear Failure Properties of Bovine Trabecular Bone","volume":"121","year":"1999","journal-title":"J. Biomech. Eng."},{"key":"2019100601341618100_B21","first-page":"1173","article-title":"An Empirical Strength Theory for Compact Bone","volume":"3","year":"1977","journal-title":"Fracture"},{"issue":"11","key":"2019100601341618100_B22","doi-asserted-by":"crossref","first-page":"2520","DOI":"10.1021\/nl061877k","article-title":"Nanogranular Origins of the Strength of Bone","volume":"6","year":"2006","journal-title":"Nano Lett."},{"issue":"1","key":"2019100601341618100_B23","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.actbio.2005.08.004","article-title":"Mechanisms Governing the Inelastic Deformation of Cortical Bone and Application to Trabecular Bone","volume":"2","year":"2006","journal-title":"Acta Biomater."},{"key":"2019100601341618100_B24","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1016\/j.jmbbm.2008.11.003","article-title":"Calibration of a Constitutive Model for the Post-Yield Behaviour of Cortical Bone","volume":"2","year":"2009","journal-title":"J. Mech. Behav. Biomed."},{"key":"2019100601341618100_B25","first-page":"1","article-title":"A Finite Element Model for Direction-Dependent Mechanical Response to Nanoindentation of Cortical Bone Allowing for Anisotropic Post-Yield Behavior of the Tissue","volume":"132","year":"2010","journal-title":"J. Biomech. Eng."},{"key":"2019100601341618100_B26","doi-asserted-by":"crossref","first-page":"1745","DOI":"10.1016\/j.jbiomech.2006.08.003","article-title":"Prediction of Strength and Strain of the Proximal Femur by a CT-Based Finite Element Method","volume":"40","year":"2007","journal-title":"J. Biomech."},{"key":"2019100601341618100_B27","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1016\/j.jmbbm.2011.11.013","article-title":"Experimental and Numerical Characterisation of the Elasto-Plastic Properties of Bovine Trabecular Bone and a Trabecular Bone Analogue","volume":"9","year":"2012","journal-title":"J. Mech. Behav. Biomed."},{"key":"2019100601341618100_B28","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1098\/rspa.1957.0133","article-title":"The Determination of the Elastic Field of an Ellipsoidal Inclusion, and Related Problems","volume":"241","year":"1957","journal-title":"Proc. R. Soc. London, Ser. A"},{"key":"2019100601341618100_B29","volume-title":"Micromechanics of Defects in Solids","year":"1987","edition":"2nd ed."},{"key":"2019100601341618100_B30","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1115\/1.3101963","article-title":"Inclusion Problems","volume":"49","year":"1996","journal-title":"Appl. Mech. Rev."},{"issue":"3","key":"2019100601341618100_B31","first-page":"3","article-title":"Elastic Fields in Double Inhomogeneity by the Equivalent Inclusion Method","volume":"68","year":"2001","journal-title":"J. Appl. Mech."},{"issue":"1","key":"2019100601341618100_B32","doi-asserted-by":"crossref","first-page":"82","DOI":"10.2106\/00004623-197658010-00015","article-title":"Aging of Bone Tissue: Mechanical Properties","volume":"58","year":"1976","journal-title":"J. Bone Jt. Surg."},{"issue":"6","key":"2019100601341618100_B33","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1016\/0021-9290(75)90075-5","article-title":"The Elastic and Ultimate Properties of Compact Bone Tissue","volume":"8","year":"1975","journal-title":"J. Biomech."},{"issue":"11","key":"2019100601341618100_B34","first-page":"57","article-title":"Hounsfield Units for Assessing Bone Mineral Density and Strength: A Tool for Osteoporosis Management","volume":"93","year":"2011","journal-title":"J. Bone Joint Surg. Am."},{"issue":"5","key":"2019100601341618100_B35","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/1350-4533(95)97314-F","article-title":"Relations of Mechanical Properties to Density and CT Numbers in Human Bone","volume":"17","year":"1995","journal-title":"Med. Eng. Phys."},{"issue":"1","key":"2019100601341618100_B36","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1109\/58.484478","article-title":"Young's Modulus Measurements of Soft Tissues with Application to Elasticity Imaging","volume":"43","year":"1996","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control."},{"key":"2019100601341618100_B37","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/S0021-9290(99)00152-9","article-title":"Prediction of Femoral Fracture Load Using Finite Element Models: An Examination of Stress- and Strain-Based Failure Theories","volume":"33","year":"2000","journal-title":"J. Biomech."},{"key":"2019100601341618100_B38","doi-asserted-by":"crossref","first-page":"3565","DOI":"10.1016\/j.jmps.2008.04.008","article-title":"Spectral Equivalent Inclusion Method: Anisotropic Cylindrical Multi-Inhomogeneities","volume":"56","year":"2008","journal-title":"J. Mech. Phys. Solids"},{"issue":"3","key":"2019100601341618100_B39","first-page":"480","article-title":"Intraoperative Fracture of the Femur in Revision Total Hip Arthroplasty with a Diaphyseal Fitting Stem","volume":"86A","year":"2004","journal-title":"J. Bone Jt. Surg."},{"key":"2019100601341618100_B40","doi-asserted-by":"crossref","first-page":"2000","DOI":"10.2106\/JBJS.H.00331","article-title":"Intraoperative Periprosthetic Fractures during Total Hip Arthroplasty: Evaluation and Management","volume":"90","year":"2008","journal-title":"J. Bone Jt. Surg."},{"issue":"3","key":"2019100601341618100_B41","first-page":"126","article-title":"Cementless Femoral Fixation in Total Hip Arthroplasty","volume":"39","year":"2010","journal-title":"Am. J. Orthop."},{"key":"2019100601341618100_B42","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/S0169-2607(98)00089-3","article-title":"Spatial Positioning of an Hip Stem Solid Model within the CT Data Set of the Host Bone","volume":"58","year":"1999","journal-title":"Comput. Meth. Prog. Biomed."},{"issue":"5","key":"2019100601341618100_B43","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1007\/s00402-001-0361-8","article-title":"Femoral Anatomy, Computed Tomography and Computer Aided Design of Prosthetic Implants","volume":"122","year":"2002","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"2019100601341618100_B44","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.jmbbm.2011.10.006","article-title":"Experimental Study of Cancellous Bone Under Large Strains and a Constitutive Probabilistic Model","volume":"6","year":"2012","journal-title":"J. Mech. Behav. Biomed."},{"key":"2019100601341618100_B45","first-page":"1006","article-title":"The Role of Fabric in the Large Strain Compressive Behavior of Human Trabecular Bone","volume":"132","year":"2010","journal-title":"ASME J. Biomech. Eng."},{"key":"2019100601341618100_B46","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1038\/nmat832","article-title":"Mechanistic Fracture Criteria for the Failure of Human Cortical Bone","volume":"2","year":"2003","journal-title":"Nature Mater."},{"issue":"10","key":"2019100601341618100_B47","doi-asserted-by":"crossref","first-page":"1249","DOI":"10.1016\/0021-9290(94)90278-X","article-title":"Fixation Pull-Out Response Measurement of Bone Screws and Porous-Surfaced Posts","volume":"27","year":"1994","journal-title":"J. Biomech."},{"key":"2019100601341618100_B48","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1016\/S0021-9290(98)00061-X","article-title":"The Effect of Hip Stem Material Modulus on Surface Strain in Human Femora","volume":"31","year":"1998","journal-title":"J. Biomech."}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4023699\/6087976\/bio_135_4_041004.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4023699\/6087976\/bio_135_4_041004.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,6]],"date-time":"2019-10-06T05:34:40Z","timestamp":1570340080000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/doi\/10.1115\/1.4023699\/370211\/An-Analytical-Approach-to-Study-the-Intraoperative"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,4,1]]},"references-count":48,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2013,4,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4023699","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,4,1]]},"article-number":"041004"}}